Merge branch 'dev/thorlbas-cs165cu' into develop #11
pymeasure_CI.yml
on: push
Docs and Linting
54s
Code Coverage on codecov
36s
Python 3.11, ubuntu-latest, numpy>=2
30s
Matrix: test
Annotations
53 errors and 31 warnings
Python 3.10, ubuntu-latest
Process completed with exit code 2.
|
Python 3.11, ubuntu-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.11, ubuntu-latest
Process completed with exit code 2.
|
Python 3.9, ubuntu-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.9, ubuntu-latest
Process completed with exit code 2.
|
Python 3.9, windows-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.9, windows-latest
Could not find micromamba activate pymeasure in C:\Users\runneradmin\.bash_profile
|
Python 3.9, windows-latest
The operation was canceled.
|
Python 3.10, windows-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.10, windows-latest
Could not find micromamba activate pymeasure in C:\Users\runneradmin\.bash_profile
|
Python 3.10, windows-latest
The operation was canceled.
|
Python 3.11, windows-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.11, windows-latest
Could not find micromamba activate pymeasure in C:\Users\runneradmin\.bash_profile
|
Python 3.11, windows-latest
The operation was canceled.
|
Python 3.12, windows-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.12, windows-latest
The operation was canceled.
|
Python 3.12, windows-latest
Could not find micromamba activate pymeasure_python312 in C:\Users\runneradmin\.bash_profile
|
Python 3.12, macos-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.12, macos-latest
The operation was canceled.
|
Python 3.12, macos-latest
ENOENT: no such file or directory, lstat '/Users/runner/work/_temp/setup-micromamba/micromamba-shell'
|
Python 3.11, macos-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.11, macos-latest
The operation was canceled.
|
Python 3.11, macos-latest
ENOENT: no such file or directory, lstat '/Users/runner/work/_temp/setup-micromamba/micromamba-shell'
|
Python 3.8, windows-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.8, windows-latest
Could not find micromamba activate pymeasure in C:\Users\runneradmin\.bash_profile
|
Python 3.8, windows-latest
The operation was canceled.
|
Python 3.9, macos-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.9, macos-latest
ENOENT: no such file or directory, lstat '/Users/runner/work/_temp/setup-micromamba/micromamba-shell'
|
Python 3.9, macos-latest
The operation was canceled.
|
Python 3.8, macos-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.8, macos-latest
The operation was canceled.
|
Python 3.8, macos-latest
ENOENT: no such file or directory, lstat '/Users/runner/work/_temp/setup-micromamba/micromamba-shell'
|
Python 3.10, macos-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.10, macos-latest
The operation was canceled.
|
Python 3.10, macos-latest
ENOENT: no such file or directory, lstat '/Users/runner/work/_temp/setup-micromamba/micromamba-shell'
|
Python 3.12, ubuntu-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.12, ubuntu-latest
The operation was canceled.
|
Code Coverage on codecov
Process completed with exit code 2.
|
Docs and Linting
Process completed with exit code 2.
|
Docs and Linting
Process completed with exit code 2.
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L70
E501 line too long (118 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L82
E501 line too long (113 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L122
E501 line too long (105 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L152
E501 line too long (119 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L166
E501 line too long (116 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/shrc203.py#L81
E501 line too long (102 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/shrc203.py#L96
E501 line too long (115 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/shrc203.py#L109
E501 line too long (114 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/optosigma/shrc203.py#L202
E501 line too long (102 > 100 characters)
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L4
E501 line too long (112 > 100 characters)
|
Python 3.11, ubuntu-latest, numpy>=2
Process completed with exit code 2.
|
Python 3.8, ubuntu-latest
The job was canceled because "ubuntu-latest_3_10" failed.
|
Python 3.8, ubuntu-latest
The request was canceled due to the configured HttpClient.Timeout of 100 seconds elapsing.
|
Docs and Linting
The following actions uses Node.js version which is deprecated and will be forced to run on node20: rbialon/flake8-annotations@v1. For more info: https://github.blog/changelog/2024-03-07-github-actions-all-actions-will-run-on-node20-instead-of-node16-by-default/
|
Docs and Linting:
docs/api/instruments/optosigma/index.rst#L1
9: WARNING: toctree contains reference to nonexisting document 'api/instruments/optosigma/ shrc203'
|
Docs and Linting:
docs/api/instruments/optosigma/index.rst#L1
9: WARNING: toctree contains reference to nonexisting document 'api/instruments/optosigma/ sbis26'
|
Docs and Linting:
docs/api/instruments/thorlabs/thorlabskst201.rst#L1
1: WARNING: Title overline too short.
|
Docs and Linting
failed to import class 'thorlabs.ThorlabsKST201' from module 'pymeasure.instruments'; the following exception was raised:
|
Docs and Linting
failed to import class 'thorlabs.ThorlabsPM100USB' from module 'pymeasure.instruments'; the following exception was raised:
|
Docs and Linting
failed to import class 'thorlabs.ThorlabsPro8000' from module 'pymeasure.instruments'; the following exception was raised:
|
Docs and Linting:
docs/api/instruments/zaber/xna08a25.rst#L1
1: WARNING: Title overline too short.
|
Docs and Linting
failed to import class 'XNA08A25' from module 'pymeasure.instruments.zaber'; the following exception was raised:
|
Docs and Linting:
docs/api/instruments/optosigma/sbis26.rst#L1
WARNING: document isn't included in any toctree
|
Docs and Linting:
docs/api/instruments/optosigma/shrc203.rst#L1
WARNING: document isn't included in any toctree
|
Docs and Linting:
docs/api/instruments/optosigma/index.rst#L1
1: WARNING: duplicate object description of pymeasure.instruments.anaheimautomation, other instance in api/instruments/anaheimautomation/index, use :noindex: for one of them
|
Docs and Linting:
docs/api/instruments/optosigma/index.rst#L1
9: WARNING: toctree contains reference to nonexisting document 'api/instruments/optosigma/ shrc203'
|
Docs and Linting:
docs/api/instruments/optosigma/index.rst#L1
9: WARNING: toctree contains reference to nonexisting document 'api/instruments/optosigma/ sbis26'
|
Docs and Linting:
docs/api/instruments/optosigma/sbis26.rst#L1
1: WARNING: Title overline too short.
|
Docs and Linting:
docs/api/instruments/optosigma/shrc203.rst#L1
1: WARNING: Title overline too short.
|
Docs and Linting:
docs/api/instruments/thorlabs/thorlabskst201.rst#L1
1: WARNING: Title overline too short.
|
Docs and Linting
failed to import class 'thorlabs.ThorlabsKST201' from module 'pymeasure.instruments'; the following exception was raised:
|
Docs and Linting
failed to import class 'thorlabs.ThorlabsPM100USB' from module 'pymeasure.instruments'; the following exception was raised:
|
Docs and Linting
failed to import class 'thorlabs.ThorlabsPro8000' from module 'pymeasure.instruments'; the following exception was raised:
|
Docs and Linting:
docs/api/instruments/zaber/xna08a25.rst#L1
1: WARNING: Title overline too short.
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L26
F401 'time.sleep' imported but unused
|
Docs and Linting:
pymeasure/instruments/optosigma/sbis26.py#L28
F401 'pymeasure.instruments.validators.strict_discrete_set' imported but unused
|
Docs and Linting:
pymeasure/instruments/optosigma/shrc203.py#L109
W291 trailing whitespace
|
Docs and Linting:
pymeasure/instruments/rigol/__init__.py#L24
W292 no newline at end of file
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L1
W291 trailing whitespace
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L3
W291 trailing whitespace
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L4
W291 trailing whitespace
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L5
W291 trailing whitespace
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L6
W291 trailing whitespace
|
Docs and Linting:
pymeasure/instruments/rigol/rigolDSA815.py#L14
W293 blank line contains whitespace
|