Releases: groupgets/purethermal1-firmware
Releases · groupgets/purethermal1-firmware
1.3.0
- Create additional altsetting with lower bandwidth
1.2.2
- Fix Y16 format descriptor to enable telemetry frame format on more systems
1.2.1
- Fix compatibility with Lepton 2.0 parts
1.2.0
- Don't overwrite Rad Enable state when switching between Y16 and RGB/YUV modes
- Apply PSUEDOCOLOR_LUT at startup so radiometric parts image as expected in colorized modes
- Return unique ID in serial number descriptor
1.1.0
- Combined support for PureThermal 1 and PureThermal 2 boards
- Additional frame descriptor for inband telemetry data in Y16 mode
- Improved Windows support for UVC extension units
- Add the ability to sent arbitrary CCI commands over extension units
1.0.0+pt2-pre
For use with PT2 board only, not compatible with PT1
Pre-release firmware for PT2
v1.0.0 release equivalent firmware with 8MHz clock as found on PT2
1.0.0
- Lepton 2 and 3 support, determined at boot
- Requested UVC data type dynamically chooses Lepton data type (no more Y16 firmware)
- Rework data transmission to eliminate dropped frames
- Pre-emptable CCI (UVC extension unit) requests so Lepton commands don't adversely affect streaming
1.0.0-pre2
- Update lepton sdk to 3.3.13
- Remove TMP007 operations by default
- Disable splashscreen by default
1.0.0-pre
Remove need for Y16 firmware with runtime AGC/pseudocolor switching
0.99.2
This release adds support for the new radiometric Lepton 2.5 and includes fixes to system stability when using CCI over UVC extension units.