Controller support Modbus slave over TCP/IP and RTU/serial.

Modbus settings are in web interface, when you can enable/disable Modbus TCP server and set Unit ID. Modbus TCP are listening on port 502.

Modbus settings

Modbus RTU can be set in serial settings, any serial interface (UART, RS-485) can be operating in Modbus slave mode. Only one interface can operate in Modbus mode!

Serial settings

Table of Modbus registers

Register Address Number Of Registers Access Description Representation
100 1 R EVSE state (A, B0, B1, C0, C1, D0, D1, E, F) char[2]
101 2 R EVSE error bits uint32
103 1 R/W Charging enabled (enabled=1, disabled=0) uint16
104 1 R/W Charger available (available=1, available=0) uint16
105 1 R Pending authorization before start charging, when authorization is required (1 when pending otherwise 0) uint16
106 1 R/W Charging current in A*10 uint16
107 2 R/W Consumption limit in Wh uint32
109 2 R/W Charging time limit in s uint32
111 1 R/W Underpower limit in W uint16
112 1 W Authorize to start charging when is pending (value 1 must be written) uint16
200 1 R Charging power in W uint16
201 2 R Session time in s uint32
203 2 R Charging time in s uint32
205 2 R Consumption in Wh uint32
207 2 R L1 voltage in mV uint32
209 2 R L2 voltage in mV uint32
211 2 R L3 voltage in mV uint32
213 2 R L1 current in mA uint32
215 2 R L2 current in mA uint32
217 2 R L3 current in mA uint32
300 1 R/W Socket outlet (enabled=1, disabled=0) uint16
301 1 R/W RCM (enabled=1, disabled=0) uint16
302 1 R/W Temperature threshold in dg.C uint16
303 1 R/W Require authorization to start charging (enabled=1, disabled=0) uint16
304 1 R/W Max charging current in A, stored in NVS uint16
305 1 R/W Default charging current in A*10, stored in NVS uint16
306 2 R/W Default consumption limit in Wh, stored in NVS uint32
308 2 R/W Default charging time limit in s, stored in NVS uint32
310 1 R/W Default underpower limit in W, stored in NVS uint16
311 1 R/W Socket lock operating time in ms uint16
312 1 R/W Socket lock break time in ms uint16
313 1 R/W Socket lock detection (unlock_high=0, locked_high=1) uint16
314 1 R/W Socket lock retry count uint16
315 1 R/W Energy meter mode (DUMMY=0, CUR=1, CUR_VLT=2) uint16
316 1 R/W Energy meter voltage in V, when is not measured uint16
317 1 R/W Energy meter three phases (enabled=1, disabled=0) uint16
400 2 R Uptime in s uint32
402 1 R Low temperature in dg.C*100 int16
403 1 R High temperature in dg.C*100 int16
404 1 R Temperature sensor count uint16
405 16 R App version char[16]
421 1 W Restart (value 1 must be written) uint16

Note Register Address starting at zero, Register Number = Register Address + 1