Rust library providing formulae for thermodynamic calculations

License

Notifications You must be signed in to change notification settings

ScaleWeather/floccus

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

88 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

floccus

License Crates.io dependency status GitHub Workflow Status

Rust crate providing formulae for air thermodynamic calculations.

This crate contains functions for computing thermodynamic quantities commonly used in atmospheric sciences. It is currently developed by one person so if there is a function you would like to be added do not hesitate to post an issue or pull request in the Github repository.

The purpose of this crate is to be an academic reference of thermodynamic formulae, so that researchers looking for a particular formula do not need to search it in the literature. Therefore all functions documentation provides a reference to the paper from which formula is taken.

Also, check the contributors guide of this crate.

How to use

To use this crate simply import it with use statement and then use desired function from chosen module.

use floccus::vapour_pressure;

//Set temperature and pressure in SI units
let temperature = 300.0; //in K
let pressure = 101325.0; //in Pa

//Compute vapour pressure using Buck (1981) formula
let vapour_pressure = vapour_pressure::buck1(temperature, pressure);

//The result is 3550.662 (f32) or 3550.6603579471303 (f64)

Naming of modules and functions

Because some thermodynamic formulae are empirical there are several ways to compute a value of given quantity. Therefore there are multiple functions available to compute the same parameter, which are grouped into modules.

The naming of modules and functions follows this convention:

vapour_pressure::buck1(temperature, pressure);

Where the module name (vapour_pressure) indicates the computed quantity, function name (buck1) indicates the author of formula and the function arguments (temperature, pressure) are variables used to compute the quantity.

Double precision

By default floccus uses single-precision (32-bit) floating-point variables. If increased accuracy is needed (at the cost of performance) double_precision feature can be enabled to use double-precision (64-bit) floating point.

Input checking

To prevent any unexpected behavior, all functions check whether provided inputs are within a reasonable range. Exact limits are specified in the documentation of each function. If the input is out of range the function will return an InputError::OutOfRange with erroneous input specified.

Debugging

If additional information is needed about which function returns the error and why, debug feature can be enabled. With that feature when returning the error function will also print the error message to log with additional information about the error. This feature potentially is not zero-cost so it is optional.

Benchmarks

Functions provided in this crate are intended for use in, i. a., numerical models. To provide the user information about performance overhead of each function all functions are benchmarked using criterion.rs. Github Actions automatically runs all benchmarks.