Skip to content

Here you find the firmware for the RAK10703 Earthquake Sensor

Notifications You must be signed in to change notification settings

RAKWireless/RAK10703-Earthquake-Sensor

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

4 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

RAK10703 WisBlock Seismic Sensor

RAKWireless RAK Unify RAKStars Assembly

Earthquakes can be dangerous and are often unpredictable. Seismic stations all around the world are measuring seismic activities. With the D7S module Omron created an affordable sensor that can detect earthquakes and measure their intensity as SI values. The SI values have a high correlation with the seismic intensity scale that indicates the magnitude of an earthquake.
While this product cannot be used to predict earthquakes, it is a good solution to send warnings and protect sensitive machinery in case an earthquake occurs. Beside of measuring the strength, it generates a warning signal if the SI level is higher than 5 that can be used to shutdown machinery. It detects as well if the horizontal position of the sensor changes, which points towards a collapse of the structure where the sensor was deployed.

Please check out Omrons documentation for the D7S module:

Using the small sized RAK12027 Seismic Sensor together with the WisBlock Core and WisBlock Base modules makes it very easy to build up the earthquake warning system.

This example can be used as a start point to write a low power consumption seismic alarm system that can be powered by battery and solar panel. The consumption in sleep mode is ~90uA. The code is completely interrupt based to keep the MCU as much as possible in sleep mode to save battery. The collected data of an earthquake is sent over LoRaWAN, but it can be used as well with LoRa P2P. It will send data packets after the D7S has finished it's data processing with the information of the SI level, PGA, shutdown alert and collapse alert signal.

Content

RAK products used in this project

This project uses the RAK19007 Base Board, the RAK12027 Seismic Sensor and optional the RAK1901 Temperature and Humidity Sensor (optional).
In case the firmware is built with the RAK-nRF52 Arduino BSP, it uses the RAK4631 Core Module.

Assembly

Place the WisBlock Core and WisBlock Sensor module in the following slots of the RAK19007 Base Board:
Assembly

Make sure to fix the modules with the screws coming with the WisBlock modules. In case of an heavy earthquake they might fall off the Base Board if not secured with the screws.

For the enclosure I used the Unify Enclosure RAKBox-UO100x75x38.
Depending on the size of the used battery, there are two mounting options.

Assemble the WisBlock Base board on the mounting plate.
Assembly

When using a smaller and thin battery (30 x 55 x 6 mm w x l x h), the battery can be placed below the mounting plate. Assembly

Fix the mounting plate inside the enclosure. Assembly

If using a larger battery, use stand-offs and a battery carrier like the one from our Awesome WisBlock repo to fix the battery above the WisBlock.
Assembly Assembly

How it works

The Arduino code are based on interrupts and timers. After joining the LoRaWAN network, the MCU goes into sleep mode until it

  • wakes up from an interrupt coming from the D7S sensor
  • wakes up from a timer to send a frequent "I am Alive" message

On wakeup, the code then checks for the wakeup reason and handles the situation.
There are 4 different interrupt events:

  • (1) Earthquake start detected (INT2 falling edge of the D7S)
  • (2) Earthquake analysis finished (INT2 raising edge of the D7S)
  • (3) Shutoff alert (INT1 falling edge of the D7S)
  • (4) Collapse alert (INT1 falling edge of the D7S)

(1) just sets a flag as reminder that an earthquake was detected (2) reads out the detected SI and PGA level and sends a packet to the LoRaWAN server (3) and (4) set a flag whether a shutoff alert or collapse alert was set

After sending the data packet in (2), a timer is started to send a second packet with the alert flags cleared.

The frequent send timer is just sending a small packet to signal the LoRaWAN server that the sensor is still alive. This packet contains the battery level and, if assembled, the temperature and humidity values measured with the RAK1901.

Libraries used

The application uses the RAK12027-D7S which is based on a library provided by Alessandro Pasqualini. The library can be installed using the Arduino Library Manager.

For the encoding of the data packets the CayenneLPP library is used.
For the RAK1901 sensor the SparkFun SHTC3 Humidity and Temperature Sensor Library is used.
These two libraries can be installed with the Arduino Library Manager.

To achieve low power consumption, the application uses the WisBlock-API-V2, which can be installed with the Arduino Library Manager as well.

Seismic Sensor code for RAK4631 using the RAK-nRF52 BSP for Arduino

The Arduino code is based on the WisBlock-API-V2, an event driven framework that handles all communication tasks in the background and just waits for a timer or external interrupt to wake up.
The provided code is for PlatformIO, but can easily be changed to work in the Arduino IDE.

Depending on the Sensor Slot used, the D7S interrupts INT1 and INT2 need to be assigned to the correct GPIO's. This can be done in the platformio.ini files with the build_flags option:

build_flags = 
	-DRAK12027_SLOT=A ; A = Slot A, B = Slot B, C = Slot C, D = Slot D, E = Slot E, F = Slot F

If using Arduino IDE, the correct assignment has to be done in the RAK12027_seismic.cpp file.

The Arduino based firmware has an RUI3 compatible AT command interface, the available AT commands can be found in the AT Command Manual

REMARK Not all RUI3 AT commands are supported because the used LoRaWAN library is different from the RUI3 LoRaWAN stack.

Setup of the RAK12027 Seismic Sensor

The functions to setup the sensor and handle the sensor interrupts are nearly the same for Arduino and RUI3. The main difference is how the interrupt handlers wake up the MCU to check the source of the interrupts.

In the `init_rak120271() function the sensor is initialized and calibrated. The calibration is necessary, as the sensor will determine his horizontal position. This is required for both the earthquake detection and the collapse alert.
This function assigns as well the interrupt handlers for the two interrupt sources from the D7S sensor.

For Arduino, the two interrupt handlers wake up the loop by releasing a semaphore with the api_wake_loop() call. They set as well the reason for the wakeup, so that it can be handled in the application.

/**
 * @brief Callback for INT 1
 * Wakes up application with signal SEISMIC_ALERT
 * Activated on Collapse and Shutoff signals
 *
 */
void d7s_int1_handler(void)
{
	api_wake_loop(STATUS | SEISMIC_ALERT);
}

/**
 * @brief Callback for INT 2
 * Wakes up application with signal SEISMIC_EVENT
 * Activated on Earthquake start and end
 *
 */
void d7s_int2_handler(void)
{
	if (digitalRead(INT2_PIN) == LOW)
	{
		digitalWrite(LED_BLUE, HIGH);
	}
	else
	{
		digitalWrite(LED_BLUE, LOW);
	}
	api_wake_loop(STATUS | SEISMIC_EVENT);
}

Data packet format

The data packet is encoded in an extended CayenneLPP format based on the CayenneLPP format provided by ElectronicCats. This format is supported by most LoRaWAN network servers and integrations, but as an extended version is used here, it will need a custom payload decoder. A payload decoders for different LoRaWAN network servers and integrations is provided in the RAKwireless Standardized Payload Repo.

The channel ID's used for the different values are:

Channel Name Channel ID Type Value
LPP_CHANNEL_BATT 1 Voltage Battery voltage in V
LPP_CHANNEL_HUMID 2 Relative Humidity RAK1901 Humidity in %RH
LPP_CHANNEL_TEMP 3 Temperature RAK1901 Temperature in °C
LPP_CHANNEL_EQ_EVENT 43 Presence RAK12027 Earthquake active, boolean value, true if earthquake is active
LPP_CHANNEL_EQ_SI 44 Analog RAK12027 Detected SI value, analog value 1/10th in m/s
LPP_CHANNEL_EQ_PGA 45 Analog RAK12027 Detected PGA value, analog 10 * value in m/s2
LPP_CHANNEL_EQ_SHUTOFF 46 Presence RAK12027 Shutoff alert, boolean value, true if alert is raised
LPP_CHANNEL_EQ_COLLAPSE 47 Presence RAK12027 Collapse alert, boolean value, true if alert is raised

To get a higher precision the SI and PGA values are multiplied by 10 before sending them. The Cayenne LPP format supports only 0.01 precision. The values must be divided by 10 to get the real values.

The packet sent out displayed as hex values looks like this: 0x2b 0x66 0x01 0x2c 0x02 0x00 0xab 0x2d 0x02 0x19 0x28 0x2e 0x66 0x01 0x2f 0x66 0x00 0x01 0x74 0x01 0x9b 0x02 0x68 0x77 0x03 0x67 0x01 0x81

Bytes Meaning Value in Hex Value
1 Channel ID 43 for EQ event 0x2b
2 Channel type for presence 0x66
3 Status of presence 0 = off, 1 = on 0x01 ON
4 Channel ID 44 for SI value 0x2c
5 Channel type for analog value 0x02
6, 7 SI value 0x00 0xab 1.71 = 0.171 m/s
8 Channel ID 44 for PGA value 0x2d
9 Channel type for analog value 0x02
10, 11 PGA value 0x19 0x28 64.4 = 6.44 m/s^2
12 Channel ID 46 for Shutoff event 0x2e
13 Channel type for presence 0x66
14 Status of presence 0 = off, 1 = on 0x01 ON
15 Channel ID 47 for Collapse event 0x2f
16 Channel type for presence 0x66
17 Status of presence 0 = off, 1 = on 0x00 OFF
18 Channel ID 1 for battery voltage 0x01
19 Channel type for voltage 0x74
20, 21 Voltage level 0x01 0x9b 4.11V
22 Channel ID 2 for humidity 0x02
23 Channel type for analog value 0x68
24 Humidity value 0x77 59.5 %RH
25 Channel ID 3 for temperature 0x03
26 Channel type for temperature 0x67
27, 28 temperature value 0x01 0x81 38.5 deg C

REMARK
The complete list of sensor data formats used by RAKwireless devices can be found in the RAKwireless Standardized Payload Repo

Example for a visualization and alert message

As an simple example to visualize the earthquake data and sending an alert, I created a device in Datacake.
Datacake is an easy to use Low Code IoT Platform. In my Datacake account I setup the device with the matching payload decoder, visualization and creation of an email alert.

Datacake payload decoder

In the device configuration the Datacake decoder from the decoders folder is used.

Datacake fields

As the SI and PGA values are sent as 10 times of the value, beside of the data fields a formula feed is required to transform the received values to the real values.

Field Name Identifier Type
Earthquake warning PRESENCE_43 Boolean
Earthquake SI value 100 ANALOG_IN_44 Float
Earthquake PGA 100 ANALOG_IN_45 Float
Battery VOLTAGE_1 Float
Humidity HUMIDITY_2 Float
Temperature TEMPERATURE_3 Float
Shutoff Alert PRESENCE_46 Boolean
Collapse Alert PRESENCE_47 Boolean
Earthquake SI value EARTHQUAKE_SI_VALUE Float
Earthquake PGA EARTHQUAKE_PGA Float
Lora Datarate LORA_DATARATE String
Lora Rssi LORA_RSSI Integer
Lora Snr LORA_SNR Integer

Datacake rule

To send a warning email when an earthquake occured, a Datacake rule is used to send the email. The rule is triggered by the Earthquake warning field. Datacake Rule

Datacake visualization

In the dashboard you can show the current status and the latest SI and PGA levels.
Datacake Rule

About

Here you find the firmware for the RAK10703 Earthquake Sensor

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published