Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Add kapelse readers support in COMPOSITE_AS_MULTISLOT mode #118
Add kapelse readers support in COMPOSITE_AS_MULTISLOT mode #118
Changes from all commits
cfa2953
8743a58
db69866
File filter
Filter by extension
Conversations
Jump to
There are no files selected for viewing
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Why this test?
In my list the KAP-LINK2 has 3 CCID interfaces https://ccid.apdu.fr/ccid/shouldwork.html#0x29470x0105
Do you have another model with a different configuration but using the same
idProduct
?There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
This test is needed as KAP-LINK2 is a USB composite device presenting either 3 CCID interfaces or 3 CCID interfaces (the 3 first ones) and a CDC-ACM interface according user configuration
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I see.
It should work fine if you something like use:
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@bmoraine Is it possible for the KAP-LINK2 to NOT have 3 CCID interfaces?
Why can't we use
max_interface_number = 2;
in all cases without checking the value ofconfig_desc->bNumInterfaces
?There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@LudovicRousseau Effectively, KAP-LINK2 has always 3 CCID interfaces (the 3 first ones) and an optional 4th CDC-ACM interface. So, you are right, we can use max_interface_number = 2; in all cases without checking the value of config_desc->bNumInterfaces