78 changes: 78 additions & 0 deletions custom_components/solvis_control/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -48,13 +48,83 @@ class ModbusFieldConfig:

PORT = 502
REGISTERS = [
ModbusFieldConfig( # Analog Out 1 Status
name="analog_out_1_status",
address=3840,
enabled_by_default=False,
device_class="",
unit="",
state_class="measurement",
entity_category="diagnostic",
),
ModbusFieldConfig( # Analog Out 2 Status
name="analog_out_2_status",
address=3845,
enabled_by_default=False,
device_class="",
unit="",
state_class="measurement",
entity_category="diagnostic",
),
ModbusFieldConfig( # Analog Out 3 Status
name="analog_out_3_status",
address=3850,
enabled_by_default=False,
device_class="",
unit="",
state_class="measurement",
entity_category="diagnostic",
),
ModbusFieldConfig( # Analog Out 4 Status
name="analog_out_4_status",
address=3855,
enabled_by_default=False,
device_class="",
unit="",
state_class="measurement",
entity_category="diagnostic",
),
ModbusFieldConfig( # Analog Out 5 Status
name="analog_out_5_status",
address=3860,
enabled_by_default=False,
device_class="",
unit="",
state_class="measurement",
entity_category="diagnostic",
),
ModbusFieldConfig( # Analog Out 6 Status
name="analog_out_6_status",
address=3865,
enabled_by_default=False,
device_class="",
unit="",
state_class="measurement",
entity_category="diagnostic",
),
ModbusFieldConfig( # Brennerleistung
name="gas_power",
address=33539,
unit="kW",
device_class="power",
state_class="measurement",
),
ModbusFieldConfig(
name="laufzeit_brennerstufe_1",
address=33536,
enabled_by_default=False,
device_class="duration",
unit="h",
state_class="measurement",
),
ModbusFieldConfig(
name="laufzeit_brennerstufe_2",
address=33538,
enabled_by_default=False,
device_class="duration",
unit="h",
state_class="measurement",
),
ModbusFieldConfig( # Außentemperatur
name="outdoor_air_temp",
address=33033,
Expand Down Expand Up @@ -702,6 +772,14 @@ class ModbusFieldConfig:
multiplier=1,
entity_category="diagnostic",
),
ModbusFieldConfig(
name="digin_error",
address=33045,
unit="",
device_class=None,
state_class=None,
entity_category="diagnostic",
),
ModbusFieldConfig( # ZirkulationBetriebsart
name="zirkulation_betriebsart",
address=2049,
Expand Down
74 changes: 74 additions & 0 deletions custom_components/solvis_control/strings.json
Original file line number Diff line number Diff line change
Expand Up @@ -292,6 +292,80 @@
},
"raumtemperatur_hkr2":{
"name":"HKR2 Raumtemperatur"
},
"laufzeit_brennerstufe_1": {
"name": "Laufzeit Brennerstufe 1"
},
"laufzeit_brennerstufe_2": {
"name": "Laufzeit Brennerstufe 2"
},
"analog_out_1_status": {
"name": "Analog Out 1 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_2_status": {
"name": "Analog Out 2 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_3_status": {
"name": "Analog Out 3 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_4_status": {
"name": "Analog Out 4 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_5_status": {
"name": "Analog Out 5 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_6_status": {
"name": "Analog Out 6 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"digin_error": {
"name": "DigIn Störungen",
"state": {
"0": "Sicherung Netzbaugruppe",
"1": "Brennerfehler",
"2": "STB1 Fehler",
"3": "STB2 Fehler",
"4": "Brenner CM424",
"5": "Solardruck",
"6": "unbekannt",
"7": "Anlagendruck",
"8": "Kondensat"
}
}
},
"switch": {
Expand Down
74 changes: 74 additions & 0 deletions custom_components/solvis_control/translations/de.json
Original file line number Diff line number Diff line change
Expand Up @@ -292,6 +292,80 @@
},
"raumtemperatur_hkr2":{
"name":"HKR2 Raumtemperatur"
},
"laufzeit_brennerstufe_1": {
"name": "Laufzeit Brennerstufe 1"
},
"laufzeit_brennerstufe_2": {
"name": "Laufzeit Brennerstufe 2"
},
"analog_out_1_status": {
"name": "Analog Out 1 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_2_status": {
"name": "Analog Out 2 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_3_status": {
"name": "Analog Out 3 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_4_status": {
"name": "Analog Out 4 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_5_status": {
"name": "Analog Out 5 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"analog_out_6_status": {
"name": "Analog Out 6 Status",
"state": {
"0": "Auto PWM",
"1": "Hand PWM",
"2": "Auto analog",
"3": "Hand analog"
}
},
"digin_error": {
"name": "DigIn Störungen",
"state": {
"0": "Sicherung Netzbaugruppe",
"1": "Brennerfehler",
"2": "STB1 Fehler",
"3": "STB2 Fehler",
"4": "Brenner CM424",
"5": "Solardruck",
"6": "unbekannt",
"7": "Anlagendruck",
"8": "Kondensat"
}
}
},
"switch": {