Releases: Gissio/radpro

2.0.3

25 Nov 16:14
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Note: this release requires an installation.

Release notes:

  • Extended conversion factor range to 25-12800 cpm/µSv/h.
  • When using sensitive detectors with a conversion factor of 600 cpm/µSv/h or higher, Rad Pro caps the pulse indication at 600 cpm/µSv/h to provide approximately one pulse per second at background levels of radiation. This does not impact the actual measurement.
  • Minor UI and performance refinements.
  • Added the Rad Pro simulator.

2.0.2 (flashtool v2)

07 Jul 15:47
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Instructions:

  • Use the update version if you have Rad Pro 2.0.1 installed.
  • Use the install version if you have Rad Pro 2.0.0 or earlier intalled.

Release notes:

  • Improved the instantaneous rate averaging algorithm.
  • Simplified the instantaneous rate averaging response curves, resulting in improved precision when using J613/J614 tubes.
  • Disabled instantaneous rate alarms in situations where the confidence interval is high, such as immediately after device startup.
  • Minor UI improvements.
  • Fixes an error in the flashtool (with FNIRSI GC-01 devices).

2.0.1

22 Jun 17:18
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Notes:

  • Added data log reset.
  • Changed the default conversion factor for J613/J614 tubes to 60.0 cpm/µSv/h.
  • Resolved issues with custom HV profiles.
  • Resolved issues with the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests.
  • Resolved issues with new history data log download.
  • Minor refinements.

2.0

06 Jun 12:50
Compare
Choose a tag to compare
2.0

By downloading this software, you agree to the Rad Pro terms and conditions.

Notes:

  • First 2.0 release.
  • Updated the UI design system to OpenBridge 5.0, improving legibility under sunlight.
  • Changed the default conversion factor for J613/J614 tubes to 30.0 cpm/µSv/h.
  • Removed the FNIRSI GC-01 display panel settings.
  • Increased the granularity and range of the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests to 100 Hz-100 kHz and 0 %-100 %, respectively (not stored on power-off).

2.0rc5 The final countdown

28 May 21:53
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

On FNIRSI GC-01 devices, make sure you select the correct display panel in display settings!

Notes:

  • Added Bosean FS-5000 support.
  • Added display panel menu for selecting the display panel (on supported devices).
  • Added secondary dose view in average measurement mode.
  • Extended conversion factor range to 25-1600 cpm/µSv/h.
  • Added 1 second datalog interval options and removed 30 seconds and 30 minutes datalog interval options.
  • Added "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection commands.
  • Added 12-hour time format.
  • Devices with data mode allow using the device while data mode is active; data mode state is also preserved after powering off.
  • Improved battery level indicator of the Bosean FS-600/FS-1000.
  • Improved battery level readout of the FS2011(STM32F051), Bosean FS-600/FS-1000.
  • Improved keyboard control scheme of the Bosean FS-1000.
  • Changed USB data connection end of line to "\r\n".
  • Minor refinements.

2.0rc4 The "little" update

27 Apr 17:35
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Notes:

  • Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
  • Added secondary CPM and count displays in measurement views.
  • Improved haptic pulse strengths.
  • Improved FNIRSI GC-01 quiet pulse clicks.
  • Improved selected menu item contrast.
  • Improved datalogging time precision.
  • Fixed History (24 h) bug.

2.0rc3 The "BIG" update

21 Apr 02:49
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Notes:

  • UI update with BIG numbers.
  • Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
  • History alert zones (1 µSv, 10 µSv).
  • Average timer expiration after reaching a configurable confidence interval.
  • Background compensation.
  • Display flashes on the FNIRSI GC-01 (after display sleep).
  • Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
  • Pulses threshold (disables pulse indication if instantaneous rate is below a certain value).
  • Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
  • Added 30 second and 10 second datalog interval options.
  • Added 10 second display sleep option.
  • Added radpro-flashtool.
  • Removed hold option.

2.0rc2

22 Mar 23:14
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Notes:

  • Changed default display theme to Dusk.
  • Fixed flash programming code.
  • Fixed FNIRSI GC-01 battery indicator.
  • Fixed conversion factor menu logic.

1.3.0

10 Jul 07:11
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Note: Rad Pro 1.3.0 uses a new settings format, thus requiring an installation rather than an update.

Notes:

  • Added data logging.
  • Added custom conversion factors.
  • Added support for the J305 Geiger tube.
  • Minor bug fixes.

1.2.2

28 Jun 19:58
Compare
Choose a tag to compare
  • Added support for devices with a GD32 microcontroller.
  • Added data submission to the https://gmcmap.com/ radiation monitoring website.