Releases: Gissio/radpro
2.0.3
By downloading this software, you agree to the Rad Pro terms and conditions.
Note: this release requires an installation.
Release notes:
- Extended conversion factor range to 25-12800 cpm/µSv/h.
- When using sensitive detectors with a conversion factor of 600 cpm/µSv/h or higher, Rad Pro caps the pulse indication at 600 cpm/µSv/h to provide approximately one pulse per second at background levels of radiation. This does not impact the actual measurement.
- Minor UI and performance refinements.
- Added the Rad Pro simulator.
2.0.2 (flashtool v2)
By downloading this software, you agree to the Rad Pro terms and conditions.
Instructions:
- Use the update version if you have Rad Pro 2.0.1 installed.
- Use the install version if you have Rad Pro 2.0.0 or earlier intalled.
Release notes:
- Improved the instantaneous rate averaging algorithm.
- Simplified the instantaneous rate averaging response curves, resulting in improved precision when using J613/J614 tubes.
- Disabled instantaneous rate alarms in situations where the confidence interval is high, such as immediately after device startup.
- Minor UI improvements.
- Fixes an error in the flashtool (with FNIRSI GC-01 devices).
2.0.1
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Added data log reset.
- Changed the default conversion factor for J613/J614 tubes to 60.0 cpm/µSv/h.
- Resolved issues with custom HV profiles.
- Resolved issues with the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests.
- Resolved issues with new history data log download.
- Minor refinements.
2.0
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- First 2.0 release.
- Updated the UI design system to OpenBridge 5.0, improving legibility under sunlight.
- Changed the default conversion factor for J613/J614 tubes to 30.0 cpm/µSv/h.
- Removed the FNIRSI GC-01 display panel settings.
- Increased the granularity and range of the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests to 100 Hz-100 kHz and 0 %-100 %, respectively (not stored on power-off).
2.0rc5 The final countdown
By downloading this software, you agree to the Rad Pro terms and conditions.
On FNIRSI GC-01 devices, make sure you select the correct display panel in display settings!
Notes:
- Added Bosean FS-5000 support.
- Added display panel menu for selecting the display panel (on supported devices).
- Added secondary dose view in average measurement mode.
- Extended conversion factor range to 25-1600 cpm/µSv/h.
- Added 1 second datalog interval options and removed 30 seconds and 30 minutes datalog interval options.
- Added "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection commands.
- Added 12-hour time format.
- Devices with data mode allow using the device while data mode is active; data mode state is also preserved after powering off.
- Improved battery level indicator of the Bosean FS-600/FS-1000.
- Improved battery level readout of the FS2011(STM32F051), Bosean FS-600/FS-1000.
- Improved keyboard control scheme of the Bosean FS-1000.
- Changed USB data connection end of line to "\r\n".
- Minor refinements.
2.0rc4 The "little" update
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
- Added secondary CPM and count displays in measurement views.
- Improved haptic pulse strengths.
- Improved FNIRSI GC-01 quiet pulse clicks.
- Improved selected menu item contrast.
- Improved datalogging time precision.
- Fixed History (24 h) bug.
2.0rc3 The "BIG" update
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- UI update with BIG numbers.
- Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
- History alert zones (1 µSv, 10 µSv).
- Average timer expiration after reaching a configurable confidence interval.
- Background compensation.
- Display flashes on the FNIRSI GC-01 (after display sleep).
- Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
- Pulses threshold (disables pulse indication if instantaneous rate is below a certain value).
- Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
- Added 30 second and 10 second datalog interval options.
- Added 10 second display sleep option.
- Added
radpro-flashtool
. - Removed hold option.
2.0rc2
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Changed default display theme to Dusk.
- Fixed flash programming code.
- Fixed FNIRSI GC-01 battery indicator.
- Fixed conversion factor menu logic.
1.3.0
By downloading this software, you agree to the Rad Pro terms and conditions.
Note: Rad Pro 1.3.0 uses a new settings format, thus requiring an installation rather than an update.
Notes:
- Added data logging.
- Added custom conversion factors.
- Added support for the J305 Geiger tube.
- Minor bug fixes.
1.2.2
- Added support for devices with a GD32 microcontroller.
- Added data submission to the https://gmcmap.com/ radiation monitoring website.