diff --git a/firmwares/zooz/ZAC36-V02.json b/firmwares/zooz/ZAC36-V02.json new file mode 100644 index 0000000..86a8e44 --- /dev/null +++ b/firmwares/zooz/ZAC36-V02.json @@ -0,0 +1,24 @@ +{ + "devices": [ + { + "brand": "Zooz", + "model": "ZAC36", + "manufacturerId": "0x027a", + "productType": "0x0101", + "productId": "0x0036", + "firmwareVersion": { + "min": "2.0", + "max": "2.255" + } + } + ], + "upgrades": [ + { + "version": "2.10.0", + "region": "usa", + "changelog": "* Includes firmware versions: 2.0, 2.10,\n* Fixed a bug: Temperature reporting frequency is now reporting correctly in minutes intervals set in parameter 45.", + "url": "https://www.getzooz.com/firmware/ZAC36LR_V02R10.gbl", + "integrity": "sha256:08afddeee935581be0cfdb277a40c950b348ae1d666ca7798bee991080a68f16" + } + ] +} diff --git a/firmwares/zooz/ZAC36.json b/firmwares/zooz/ZAC36.json index 36fddef..72ee985 100644 --- a/firmwares/zooz/ZAC36.json +++ b/firmwares/zooz/ZAC36.json @@ -15,6 +15,7 @@ "upgrades": [ { "version": "1.24.0", + "region": "usa", "changelog": "* Includes firmware versions: 1.0, 1.10, 1.12, 1.13, 1.14, 1.15, 1.19, 1.21, 1.24\n* Fixed the auto-close function when a low battery alert is triggered and the backup battery is connected and charging. The valve will not auto-close anymore.\n* Fixed the battery level report issue not showing 100% when the backup battery is fully charged.\n* Correct the battery status display from 'discharging' to 'maintaining' when the backup battery is fully charged.", "url": "https://www.getzooz.com/firmware/ZAC36_V01R24.gbl", "integrity": "sha256:8ed65c3d74daad06662513d23b36f764cfad3aac8a4eb8be9cf788e1dc45c26f" diff --git a/firmwares/zooz/ZEN15-V02.json b/firmwares/zooz/ZEN15-V02.json new file mode 100644 index 0000000..33d46ab --- /dev/null +++ b/firmwares/zooz/ZEN15-V02.json @@ -0,0 +1,24 @@ +{ + "devices": [ + { + "brand": "Zooz", + "model": "ZEN15", + "manufacturerId": "0x027a", + "productType": "0x0101", + "productId": "0x000d", + "firmwareVersion": { + "min": "2.0", + "max": "2.255" + } + } + ], + "upgrades": [ + { + "version": "2.10.0", + "region": "usa", + "changelog": "* Includes firmware versions: 2.0, 2.10 \n* Added Notification Command Class. The Power Switch will now report (Over-current detected) when parameter 20 (overload protection) is triggered.\n* Added parameter 175 - Voltage threshold report.\n* Added parameter 176 - Electricity threshold report.\n* dded parameter 36 - Turn the power switch on again after the overload protection is triggered.\n* Modified parameter 20: The overload protection cannot be turned off anymore, and it can be adjusted between 2 - 5 seconds. \n* Fixed a bug when the Power Switch could turn off in edge cases when a large appliance like a dryer was initially starting. The Power Switch will no longer turn off on the initial start up unless overload protection is triggered.", + "url": "https://www.getzooz.com/firmware/ZEN15_V02R10.gbl", + "integrity": "sha256:124567676cde796107146ad644dd74832227a914bf80114feba525660768b233" + } + ] +} diff --git a/firmwares/zooz/ZEN16-V02.json b/firmwares/zooz/ZEN16-V02.json new file mode 100644 index 0000000..f66cb30 --- /dev/null +++ b/firmwares/zooz/ZEN16-V02.json @@ -0,0 +1,24 @@ +{ + "devices": [ + { + "brand": "Zooz", + "model": "ZEN16", + "manufacturerId": "0x027a", + "productType": "0xa000", + "productId": "0xa00a", + "firmwareVersion": { + "min": "2.0", + "max": "2.255" + } + } + ], + "upgrades": [ + { + "version": "2.10.0", + "region": "usa", + "changelog": "* Includes firmware versions: 2.0, 2.10 \n* Added a new value for parameter 24 (DC Motor mode) for the application with 3-speed fans/motors, so that only 1 relay can be turned on at the same time.\n* Fixed setting bug: you can now set any value for parameters 2, 3, and 4 (input type) when parameter 24 (DC motor mode) is set to value 1 or 2 (enabled).\n* Fixed a bug with the auto turn-off timer for R1, R2, and R3 whenever parameters 12, 13, and 14 are changed from value 1 to 0. Parameters 2, 3, and 4 values 0-10 were affected.\n* Added new settings to set input trigger duration (parameters 28, 29, and 30,).\n* Added new setting to assign fixed on or off actions to inputs (parameter 31).", + "url": "https://www.getzooz.com/firmware/ZEN16_V02R10.gbl", + "integrity": "sha256:01c080fcb7cf6082d18d5878824d26b7c3a49d1a6c72ecce5207e2c4892f7272" + } + ] +} diff --git a/firmwares/zooz/ZEN20-V04.json b/firmwares/zooz/ZEN20-V04.json new file mode 100644 index 0000000..7fb74e3 --- /dev/null +++ b/firmwares/zooz/ZEN20-V04.json @@ -0,0 +1,24 @@ +{ + "devices": [ + { + "brand": "Zooz", + "model": "ZEN20", + "manufacturerId": "0x027a", + "productType": "0xa000", + "productId": "0xa004", + "firmwareVersion": { + "min": "4.0", + "max": "4.255" + } + } + ], + "upgrades": [ + { + "version": "4.20.1", + "region": "usa", + "changelog": "* Includes firmware versions: 4.0, 4.10, 4.20 \n* Fixed a bug: Reports from Meter Command Class might be affected on the selected platforms.\n* Fixed a bug: Parameter 37, the software was reporting incorrect units for Current threshold.\n* The current and power acquisition algorithm has been optimized to reduce the intermediate reporting data.\n* Improved meter reporting when a value changes from non-zero (last reported value) to zero (current value).", + "url": "https://www.getzooz.com/firmware/ZEN20_V04R20.gbl", + "integrity": "sha256:edf818919c834e6aa70b3dba9a14e7bb0035b114c35ac27116b6319a72d86a80" + } + ] +}