VE.Bus: Peak shaving current limit setting affects input current limit settings #1391

Open
vejpasop opened this issue Nov 15, 2024 · 0 comments
Assignees
Labels

Comments

@vejpasop
Copy link
Collaborator

Bug since. tbd

When the peak shaving current limit is used the set value shows up in the AC input current limit setting and prevents the user from setting that setting to a higher value.

How?:
The peak shaving current limit writes to mk2-dbus /Hub4/Lx/OverruledShoreLimit. -> The ESS assistant temporarily overwrites the active current limit and communicates this back in the AC info frame -> AC input current limit setting shows the peak shaving current limit,

Work around: Disable the peak shaving, wait a minute (there is a 60 second time out on the overruled shore limit, then adjust their AC input limit, and then they can re-enable peak shaving.