From 4b414bfddbdabf8bfc0a730afb6cd0ef6e69570e Mon Sep 17 00:00:00 2001 From: Dhanya Thattil Date: Sun, 12 Nov 2023 15:39:58 +0100 Subject: [PATCH] release notes --- RELEASE.txt | 23 ++++++++++++++++------- 1 file changed, 16 insertions(+), 7 deletions(-) diff --git a/RELEASE.txt b/RELEASE.txt index dec4269093..cb8aeeb5fe 100644 --- a/RELEASE.txt +++ b/RELEASE.txt @@ -1,4 +1,4 @@ -SLS Detector Package Major Release 7.0.3 released on 10.11.2023 +SLS Detector Package Major Release 7.0.3 released on 13.11.2023 =============================================================== This document describes the differences between v7.0.3 and v7.0.2 @@ -22,25 +22,28 @@ This document describes the differences between v7.0.3 and v7.0.2 Firmware -------- + * [Eiger] Blocking trigger on quad Previously, blocking software trigger on a quad was not blocking. Fixed with firmware v32. - Client ------ + * Limit port number max to 65535 Previously, one could set the port numbers (TCP, UDP, ZMQ) to values higher than 65535 and also to 0. However, it was truncated to 16 bit in the background, but not relayed to the user. Now, it will throw if it is 0 or greater than 65535 (16 bit). + * Stopping acqusition for a single or subset of modules The Detector API previously stopped all modules. Now, it takes into account which modules the user wanted to stop. + * [Jungfrau] Stop in sync mode When stopping acquisition in sync mode, only the master module sometimes returns 'Idle' state instead of 'Stopped'. The software threw an @@ -48,6 +51,7 @@ This document describes the differences between v7.0.3 and v7.0.2 Now, it does not throw and a fix will be added to the next firmware release for the different states (with SW release: v8.0.0). + * [Eiger] Incorrect error message in Stop When stopping acquisition, if a half module were to give an error in a rare case while the others succeeded, this would result in an re-attempt @@ -57,21 +61,22 @@ This document describes the differences between v7.0.3 and v7.0.2 immediately. - Receiver -------- + * Limit TCP port number (command line) to max of 65535 Refer issue under 'Client'. - Detector Simulator ------------------ + * Limit TCP port number (command line) to max of 65535 Refer issue under 'Client'. + * Some commands such as 'readnrows' would complain that it cannot be set because the detector is not idle, but was setting it anyway. Fixed. @@ -79,16 +84,19 @@ This document describes the differences between v7.0.3 and v7.0.2 Gui/ Client Callback -------------------- + * [Jungfrau] Gui: corrected color map of gain plot Previously, color on the gain plot did not update after the first image, unless there were x/y min/max changes or window resizing. Fixed. + * [Jungfrau] Acquisition finished callback error status in sync mode When stopping acquisition in multi module Jungfrau sync mode, different status (master 'idle' and slaves 'stopped' in firmware 2.4.1 or 1.4.1) show as 'error' in acquisition finished call back (mainly used for gui). This is fixed. + * [Jungfrau] Gui: Next frame number shown as 0 for inconsistency When stopping an acquisition in a multi module Jungfrau, the next frame numbers might be different, for which the Gui shows an error message @@ -97,13 +105,14 @@ This document describes the differences between v7.0.3 and v7.0.2 that 0 is an invalid input. - Data Processing --------------- + * [Moench] Segmentation fault with moench03RawDataPrcess Previously, it crashed when nframes > 0. Fixed. + * [Moench] Moench interpolation issues fixed. @@ -142,8 +151,8 @@ This document describes the differences between v7.0.3 and v7.0.2 Eiger 02.10.2023 (v32) (updated in 7.0.3) - Jungfrau 16.05.2023 (v1.4.1, HW v1.0) (updated in 7.0.3) - 15.05.2023 (v2.4.1, HW v2.0) (updated in 7.0.3) + Jungfrau 16.05.2023 (v1.4.1, HW v1.0) (updated in 7.0.2) + 15.05.2023 (v2.4.1, HW v2.0) (updated in 7.0.2) Mythen3 24.01.2023 (v1.4) (updated in 7.0.0)