You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I was using a super admin account and created a charging station template. However, whenever I tried to edit it, it will stuck before the edit window pop out. The whole page darken a bit but no window pop out for me to edit.
I was just trying implement one for testing purpose, therefore the data is just random number and string (they are in the correct data type). Also, I could not find the saved record in MongoDB server. Is it not where it is being stored? If yes then where is it stored?
I was using a super admin account and created a charging station template. However, whenever I tried to edit it, it will stuck before the edit window pop out. The whole page darken a bit but no window pop out for me to edit.
I was just trying implement one for testing purpose, therefore the data is just random number and string (they are in the correct data type). Also, I could not find the saved record in MongoDB server. Is it not where it is being stored? If yes then where is it stored?
Not sure is it because how I implemented the template, it is acting a bit glitchy overall. Here's my setting for the template:
`{
"supervisionUrlOcppConfiguration": true,
"supervisionUrlOcppKey": "ocppcentraladdress",
"idTagsFile": "idtags.json",
"baseName": "CS-EVLINK",
"chargePointModel": "MONOBLOCK",
"chargePointVendor": "Schneider Electric",
"chargeBoxSerialNumberPrefix": "EV.2S7P04",
"firmwareVersionPattern": "^(0|[1-9]\d*)\.(0|[1-9]\d*)\.(0|[1-9]\d*)\.(0|[1-9]\d*)$",
"firmwareVersion": "3.3.0.10",
"power": 7360,
"powerUnit": "W",
"numberOfPhases": 1,
"numberOfConnectors": 1,
"randomConnectors": false,
"voltageOut": 231,
"amperageLimitationOcppKey": "maxintensitysocket",
"Configuration": {
"configurationKey": [
{
"key": "MeterValuesSampledData",
"readonly": false,
"value": "Energy.Active.Import.Register,Current.Import,Voltage"
},
{
"key": "MeterValueSampleInterval",
"readonly": false,
"value": "30"
},
{
"key": "SupportedFeatureProfiles",
"readonly": true,
"value": "Core,FirmwareManagement,LocalAuthListManagement,SmartCharging,RemoteTrigger,Reservation"
},
{
"key": "LocalAuthListEnabled",
"readonly": false,
"value": "false"
},
{
"key": "AuthorizeRemoteTxRequests",
"readonly": false,
"value": "false"
},
{
"key": "WebSocketPingInterval",
"readonly": false,
"value": "60"
},
{
"key": "ReserveConnectorZeroSupported",
"readonly": false,
"value": "false"
}
]
},
"AutomaticTransactionGenerator": {
"enable": false,
"minDuration": 60,
"maxDuration": 80,
"minDelayBetweenTwoTransactions": 15,
"maxDelayBetweenTwoTransactions": 30,
"probabilityOfStart": 1,
"stopAfterHours": 0.3,
"stopOnConnectionFailure": false,
"requireAuthorize": true
},
"Connectors": {
"0": {},
"1": {
"MeterValues": [
{
"unit": "Wh",
"context": "Sample.Periodic",
"value": 0
}
]
}
},
"technical": {
"connectors": [
{"connectorId": "0", "type": "T1", "power": "7000", "chargePointID": "2131"},
{"connectorId": "1", "type": "T1", "power": "7000", "chargePointID": "2131"}
],
"masterSlave": true,
"maximumPower": "5000",
"voltage": "300",
"powerLimitUnit": "W",
"excludeFromPowerLimitation": false,
"chargePoints": [
{
"chargePointID": "2131",
"currentType": "AC",
"amperage": "12",
"efficiency": "12",
"numberOfConnectedPhase": "1",
"cannotChargeInParallel": true,
"sharePowerToAllConnectors": true,
"excludeFromPowerLimitation": false,
"ocppParamForPowerLimitation": "IDK",
"power": "7000",
"connectorIDs": ["0","1"]
}
},
"capabilities": [
{
"supportedFirmwareVersions": ["A123", "A321"],
"supportedOcppVersions": ["B123","B321"],
"capabilities":{
"supportStaticLimitation": true,
"supportChargingProfiles": true,
"supportRemoteStartStopTransaction": true,
"supportUnlockConnector": true,
"supportReservation": true,
"supportCreditCard": true,
"supportRFIDCard": true
}
}
],
"ocppVendorParameters": [{
"supportedFirmwareVersions": ["A123", "A321"],
"supportedOcppVersions": ["B123","B321"],
"parameters": {"string": "string"}
}],
"ocppStandardParameters": [{
"supportedFirmwareVersions": ["A123", "A321"],
"supportedOcppVersions": ["B123","B321"],
"parameters": {
"string": "string",
"AllowOfflineTxForUnknownId": false
}
}]
}`
Thank you in advance!
The text was updated successfully, but these errors were encountered: