Central_heating sensor activated by automatically heating domestic hot water #255

Open
bjornmorsman opened this issue Dec 22, 2024 · 4 comments
Labels
question Further information is requested

Comments

@bjornmorsman
Copy link

bjornmorsman commented Dec 22, 2024

Hello,

i have a strange situation with the software, when my boiler (itho base cube) is automatically heating dhw water the sensor central_heating gets activated. Buth the central heating is not running. When i turn on the hot water the sensor domestic_hot_water get active.

my boiler has multiple states for heating, heating hot water and heating cv.

im using version 0.10.2
Is this an bug in the software of the esp or is this normal behavior?

thanks in advance

@rvdbreemen rvdbreemen added the question Further information is requested label Dec 22, 2024
@rvdbreemen
Copy link
Owner

Hi @bjornmorsman

It is not a bug, it is normal l that when you turn on hot water your hot water indicator is ON. The boiler is then heating.

Hope that explains,
Robert

@bjornmorsman
Copy link
Author

Hi robert,

thats not what i ment, my central_heating indicator goes on when my dhw water is heating

thank you

@rvdbreemen
Copy link
Owner

Hi @bjornmorsman

Can you share some logging. So I can see the messages that are being sent?

Thanks
Robert

@bjornmorsman
Copy link
Author

Hi @rvdbreemen

i added the log below. At 19:29:34 central_heating goes to on in home assistant and at 19:31:36 it goes to off. central_heating_enable and domestic_hot_water are off at that moment.

hope you can help.

19:28:01.110704	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:01.267444	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:02.109316	T10010A00	Write-Data	Control setpoint: 10.00
19:28:02.265529	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:03.109274	T80000200	Read-Data 	Status: 00000010 00000000
19:28:03.251897	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:04.109870	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:04.266355	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:05.615106	T900E6400	Write-Data	Maximum relative modulation level: 100.00
19:28:05.639793	B500E6400	Write-Ack 	Maximum relative modulation level: 100.00
19:28:06.102453	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:06.259816	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:07.093895	T10010A00	Write-Data	Control setpoint: 10.00
19:28:07.252772	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:08.096838	T80000200	Read-Data 	Status: 00000010 00000000
19:28:08.250449	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:09.092842	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:09.236766	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:10.614437	T10101400	Write-Data	Room setpoint: 20.00
19:28:10.639899	BD0101400	Write-Ack 	Room setpoint: 20.00
19:28:11.076096	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:11.232813	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:12.090141	T10010A00	Write-Data	Control setpoint: 10.00
19:28:12.241811	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:13.074020	T80000200	Read-Data 	Status: 00000010 00000000
19:28:13.216174	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:14.058540	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:14.233366	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:15.618673	T10181533	Write-Data	Room temperature: 21.20
19:28:15.643849	BD0181533	Write-Ack 	Room temperature: 21.20
19:28:16.066151	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:16.213932	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:17.051115	T10010A00	Write-Data	Control setpoint: 10.00
19:28:17.215791	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:18.083851	T80000200	Read-Data 	Status: 00000010 00000000
19:28:18.239919	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:19.049012	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:19.200215	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:20.604549	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:20.634594	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:21.046263	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:21.190550	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:22.028920	T10010A00	Write-Data	Control setpoint: 10.00
19:28:22.187472	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:23.043000	T80000200	Read-Data 	Status: 00000010 00000000
19:28:23.186266	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:24.025308	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:24.185086	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:25.599780	T00390000	Read-Data 	Max CH water setpoint: 0.00
19:28:25.627176	B40393200	Read-Ack  	Max CH water setpoint: 50.00
19:28:26.030625	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:26.184826	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:27.029496	T10010A00	Write-Data	Control setpoint: 10.00
19:28:27.176438	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:28.013982	T80000200	Read-Data 	Status: 00000010 00000000
19:28:28.171892	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:29.020054	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:29.171438	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:30.599499	T1002010D	Write-Data	Master configuration: 00000001 13
19:28:30.625867	BD002010D	Write-Ack 	Master configuration: 00000001 13
19:28:31.013986	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:31.153794	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:31.999305	T10010A00	Write-Data	Control setpoint: 10.00
19:28:32.142989	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:33.007319	T80000200	Read-Data 	Status: 00000010 00000000
19:28:33.140633	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:33.996478	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:34.142950	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:35.620434	T00030000	Read-Data 	Slave configuration: 00000000 0
19:28:35.646488	BC003111D	Read-Ack  	Slave configuration: 00010001 29
19:28:35.987779	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:36.147719	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:37.005749	T10010A00	Write-Data	Control setpoint: 10.00
19:28:37.132615	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:37.988162	T80000200	Read-Data 	Status: 00000010 00000000
19:28:38.138307	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:38.989681	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:39.131516	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:40.610450	T00050000	Read-Data 	Application-specific flags: 00000000 0
19:28:40.644063	BC0050000	Read-Ack  	Application-specific flags: 00000000 0
19:28:40.976238	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:41.119455	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:41.980025	T10010A00	Write-Data	Control setpoint: 10.00
19:28:42.125075	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:42.964586	T80000200	Read-Data 	Status: 00000010 00000000
19:28:43.121789	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:43.967666	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:44.128266	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:45.607058	T00090000	Read-Data 	Remote override room setpoint: 0.00
19:28:45.638615	R801C0000	Read-Data 	Return water temperature: 0.00
19:28:45.696679	BC01C1500	Read-Ack  	Return water temperature: 21.00
19:28:45.750404	AC0090000	Read-Ack  	Remote override room setpoint: 0.00
19:28:45.873588	OT: 2.60
19:28:45.967735	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:46.119519	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:46.950263	T10010A00	Write-Data	Control setpoint: 10.00
19:28:47.110321	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:47.954107	T80000200	Read-Data 	Status: 00000010 00000000
19:28:48.110733	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:48.953062	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:49.107075	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:50.616277	T900E6400	Write-Data	Maximum relative modulation level: 100.00
19:28:50.642169	B500E6400	Write-Ack 	Maximum relative modulation level: 100.00
19:28:50.937934	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:51.108507	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:51.945743	T10010A00	Write-Data	Control setpoint: 10.00
19:28:52.099289	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:52.940313	T80000200	Read-Data 	Status: 00000010 00000000
19:28:53.082204	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:53.938732	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:54.093399	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:55.605559	T10101400	Write-Data	Room setpoint: 20.00
19:28:55.630900	BD0101400	Write-Ack 	Room setpoint: 20.00
19:28:55.945136	T80190000	Read-Data 	Boiler water temperature: 0.00
19:28:56.082792	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:28:56.922448	T10010A00	Write-Data	Control setpoint: 10.00
19:28:57.080071	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:28:57.937707	T80000200	Read-Data 	Status: 00000010 00000000
19:28:58.086475	B40000200	Read-Ack  	Status: 00000010 00000000
19:28:58.908209	T00110000	Read-Data 	Relative modulation level: 0.00
19:28:59.066138	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:28:59.493508	SC: 19:29/7
19:29:00.013191	Command: SC=19:29/7
19:29:00.602398	T10181533	Write-Data	Room temperature: 21.20
19:29:00.627517	BD0181533	Write-Ack 	Room temperature: 21.20
19:29:00.675528	SC: 19:29/7
19:29:00.918792	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:01.061795	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:01.918949	T10010A00	Write-Data	Control setpoint: 10.00
19:29:02.068639	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:02.910598	T80000200	Read-Data 	Status: 00000010 00000000
19:29:03.057409	B40000200	Read-Ack  	Status: 00000010 00000000
19:29:03.918347	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:04.049641	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:04.899815	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:05.613282	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:05.884991	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:06.043461	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:06.886648	T10010A00	Write-Data	Control setpoint: 10.00
19:29:07.032371	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:07.886588	T80000200	Read-Data 	Status: 00000010 00000000
19:29:08.029049	B40000200	Read-Ack  	Status: 00000010 00000000
19:29:08.885614	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:09.031022	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:09.883293	T00390000	Read-Data 	Max CH water setpoint: 0.00
19:29:10.611402	B40393200	Read-Ack  	Max CH water setpoint: 50.00
19:29:10.877896	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:11.025619	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:11.869582	T10010A00	Write-Data	Control setpoint: 10.00
19:29:12.027031	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:12.870132	T80000200	Read-Data 	Status: 00000010 00000000
19:29:13.024303	B40000200	Read-Ack  	Status: 00000010 00000000
19:29:13.873216	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:14.011437	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:14.870810	T1002010D	Write-Data	Master configuration: 00000001 13
19:29:15.599214	BD002010D	Write-Ack 	Master configuration: 00000001 13
19:29:15.866861	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:16.013955	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:16.867520	T10010A00	Write-Data	Control setpoint: 10.00
19:29:17.014770	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:17.855894	T80000200	Read-Data 	Status: 00000010 00000000
19:29:18.035014	B40000200	Read-Ack  	Status: 00000010 00000000
19:29:18.853237	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:19.009480	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:19.841612	T00030000	Read-Data 	Slave configuration: 00000000 0
19:29:20.601647	BC003111D	Read-Ack  	Slave configuration: 00010001 29
19:29:20.855330	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:21.007122	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:21.841036	T10010A00	Write-Data	Control setpoint: 10.00
19:29:21.982901	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:22.826622	T80000200	Read-Data 	Status: 00000010 00000000
19:29:23.002003	B40000200	Read-Ack  	Status: 00000010 00000000
19:29:23.827261	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:23.986795	B40113400	Read-Ack  	Relative modulation level: 52.00
19:29:24.842844	T00050000	Read-Data 	Application-specific flags: 00000000 0
19:29:25.610895	BC0050000	Read-Ack  	Application-specific flags: 00000000 0
19:29:25.826421	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:25.967556	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:26.838446	T10010A00	Write-Data	Control setpoint: 10.00
19:29:26.970411	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:27.810148	T80000200	Read-Data 	Status: 00000010 00000000
19:29:27.968474	B40000200	Read-Ack  	Status: 00000010 00000000
19:29:28.815139	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:28.968309	B40113400	Read-Ack  	Relative modulation level: 52.00
19:29:29.809013	T00090000	Read-Data 	Remote override room setpoint: 0.00
19:29:29.836090	R00120000	Read-Data 	CH water pressure: 0.00
19:29:30.604061	B40120182	Read-Ack  	CH water pressure: 1.51
19:29:30.635012	AC0090000	Read-Ack  	Remote override room setpoint: 0.00
19:29:30.810066	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:30.968960	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:31.812754	T10010A00	Write-Data	Control setpoint: 10.00
19:29:31.969506	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:32.810519	T80000200	Read-Data 	Status: 00000010 00000000
19:29:32.952524	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:33.798617	T80000200	Read-Data 	Status: 00000010 00000000
19:29:33.949860	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:34.790958	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:35.599866	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:35.791017	T80000200	Read-Data 	Status: 00000010 00000000
19:29:35.945205	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:36.788763	T900E6400	Write-Data	Maximum relative modulation level: 100.00
19:29:36.948114	B500E6400	Write-Ack 	Maximum relative modulation level: 100.00
19:29:37.794998	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:37.933443	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:38.789609	T10010A00	Write-Data	Control setpoint: 10.00
19:29:38.933666	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:39.773847	T80000200	Read-Data 	Status: 00000010 00000000
19:29:40.599568	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:40.774502	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:40.931558	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:41.777205	T10101400	Write-Data	Room setpoint: 20.00
19:29:41.929807	BD0101400	Write-Ack 	Room setpoint: 20.00
19:29:42.762884	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:42.919998	BC0191500	Read-Ack  	Boiler water temperature: 21.00
19:29:43.778477	T10010A00	Write-Data	Control setpoint: 10.00
19:29:43.927938	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:44.765068	T80000200	Read-Data 	Status: 00000010 00000000
19:29:45.621565	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:45.771612	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:45.915832	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:46.763217	T10181533	Write-Data	Room temperature: 21.20
19:29:46.905612	BD0181533	Write-Ack 	Room temperature: 21.20
19:29:47.768095	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:47.920737	BC0191600	Read-Ack  	Boiler water temperature: 22.00
19:29:48.748758	T10010A00	Write-Data	Control setpoint: 10.00
19:29:48.907876	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:49.760638	T80000200	Read-Data 	Status: 00000010 00000000
19:29:49.916562	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:50.751237	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:50.903281	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:51.765470	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:51.940635	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:52.734901	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:52.894389	B40191700	Read-Ack  	Boiler water temperature: 23.00
19:29:53.751366	T10010A00	Write-Data	Control setpoint: 10.00
19:29:53.879170	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:54.737166	T80000200	Read-Data 	Status: 00000010 00000000
19:29:54.880733	B4000020A	Read-Ack  	Status: 00000010 00001010
19:29:55.734907	T00110000	Read-Data 	Relative modulation level: 0.00
19:29:55.900487	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:29:56.719542	T00390000	Read-Data 	Max CH water setpoint: 0.00
19:29:56.878575	B40393200	Read-Ack  	Max CH water setpoint: 50.00
19:29:57.719895	T80190000	Read-Data 	Boiler water temperature: 0.00
19:29:57.861865	BC0191880	Read-Ack  	Boiler water temperature: 24.50
19:29:58.718125	T10010A00	Write-Data	Control setpoint: 10.00
19:29:58.880711	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:29:59.482458	SC: 19:30/7
19:29:59.718398	T80000200	Read-Data 	Status: 00000010 00000000
19:29:59.860127	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:00.001160	Command: SC=19:30/7
19:30:00.622685	SC: 19:30/7
19:30:00.718473	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:00.864041	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:01.704425	T1002010D	Write-Data	Master configuration: 00000001 13
19:30:01.863140	BD002010D	Write-Ack 	Master configuration: 00000001 13
19:30:02.706473	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:02.858367	B40191980	Read-Ack  	Boiler water temperature: 25.50
19:30:03.690986	T10010A00	Write-Data	Control setpoint: 10.00
19:30:03.849439	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:04.700130	T80000200	Read-Data 	Status: 00000010 00000000
19:30:04.854272	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:05.693274	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:05.852376	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:06.693597	T00030000	Read-Data 	Slave configuration: 00000000 0
19:30:06.850202	BC003111D	Read-Ack  	Slave configuration: 00010001 29
19:30:07.679551	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:07.836813	BC0191B80	Read-Ack  	Boiler water temperature: 27.50
19:30:08.691228	T10010A00	Write-Data	Control setpoint: 10.00
19:30:08.836777	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:09.676267	T80000200	Read-Data 	Status: 00000010 00000000
19:30:09.834247	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:10.683753	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:10.819873	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:11.675368	T00050000	Read-Data 	Application-specific flags: 00000000 0
19:30:11.819595	BC0050000	Read-Ack  	Application-specific flags: 00000000 0
19:30:12.659070	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:12.818426	B40191C80	Read-Ack  	Boiler water temperature: 28.50
19:30:13.662425	T10010A00	Write-Data	Control setpoint: 10.00
19:30:13.820553	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:14.677825	T80000200	Read-Data 	Status: 00000010 00000000
19:30:14.804695	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:15.663401	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:15.804988	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:16.646275	T00090000	Read-Data 	Remote override room setpoint: 0.00
19:30:16.671639	R00120000	Read-Data 	CH water pressure: 0.00
19:30:16.821212	B40120182	Read-Ack  	CH water pressure: 1.51
19:30:16.846314	AC0090000	Read-Ack  	Remote override room setpoint: 0.00
19:30:17.647529	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:17.807471	BC0191D80	Read-Ack  	Boiler water temperature: 29.50
19:30:18.651258	T10010A00	Write-Data	Control setpoint: 10.00
19:30:18.793092	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:19.641709	T80000200	Read-Data 	Status: 00000010 00000000
19:30:19.794858	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:20.635180	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:20.795789	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:21.637429	T900E6400	Write-Data	Maximum relative modulation level: 100.00
19:30:21.801277	B500E6400	Write-Ack 	Maximum relative modulation level: 100.00
19:30:22.638069	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:22.810795	BC0191E80	Read-Ack  	Boiler water temperature: 30.50
19:30:23.637032	T10010A00	Write-Data	Control setpoint: 10.00
19:30:23.787158	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:24.620473	T80000200	Read-Data 	Status: 00000010 00000000
19:30:24.777683	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:25.622089	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:25.776361	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:26.619476	T10101400	Write-Data	Room setpoint: 20.00
19:30:26.777099	BD0101400	Write-Ack 	Room setpoint: 20.00
19:30:27.621836	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:27.762556	BC0192000	Read-Ack  	Boiler water temperature: 32.00
19:30:28.619005	T10010A00	Write-Data	Control setpoint: 10.00
19:30:28.777893	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:29.617220	T80000200	Read-Data 	Status: 00000010 00000000
19:30:29.770786	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:30.616018	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:30.762926	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:31.610046	T10181535	Write-Data	Room temperature: 21.21
19:30:31.759087	BD0181535	Write-Ack 	Room temperature: 21.21
19:30:32.598881	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:32.757871	B40192100	Read-Ack  	Boiler water temperature: 33.00
19:30:33.597980	T10010A00	Write-Data	Control setpoint: 10.00
19:30:33.761635	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:34.583462	T80000200	Read-Data 	Status: 00000010 00000000
19:30:34.741136	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:35.602607	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:35.742199	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:36.580507	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:36.740616	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:37.595508	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:37.752393	B40192200	Read-Ack  	Boiler water temperature: 34.00
19:30:38.581856	T10010A00	Write-Data	Control setpoint: 10.00
19:30:38.741780	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:39.576610	T80000200	Read-Data 	Status: 00000010 00000000
19:30:39.727519	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:40.598777	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:40.726710	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:41.568642	T00390000	Read-Data 	Max CH water setpoint: 0.00
19:30:41.742881	B40393200	Read-Ack  	Max CH water setpoint: 50.00
19:30:42.561487	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:42.712923	B40192400	Read-Ack  	Boiler water temperature: 36.00
19:30:43.555111	T10010A00	Write-Data	Control setpoint: 10.00
19:30:43.712568	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:44.557960	T80000200	Read-Data 	Status: 00000010 00000000
19:30:44.712078	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:45.611133	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:45.699934	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:46.552415	T1002010D	Write-Data	Master configuration: 00000001 13
19:30:46.702971	BD002010D	Write-Ack 	Master configuration: 00000001 13
19:30:47.544044	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:47.702773	BC0192500	Read-Ack  	Boiler water temperature: 37.00
19:30:48.546031	T10010A00	Write-Data	Control setpoint: 10.00
19:30:48.700162	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:49.532161	T80000200	Read-Data 	Status: 00000010 00000000
19:30:49.692144	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:50.599538	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:50.694388	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:51.534826	T00030000	Read-Data 	Slave configuration: 00000000 0
19:30:51.677985	BC003111D	Read-Ack  	Slave configuration: 00010001 29
19:30:52.537091	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:52.692345	B40192680	Read-Ack  	Boiler water temperature: 38.50
19:30:53.522092	T10010A00	Write-Data	Control setpoint: 10.00
19:30:53.677587	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:54.533828	T80000200	Read-Data 	Status: 00000010 00000000
19:30:54.678682	B4000020A	Read-Ack  	Status: 00000010 00001010
19:30:55.612817	T00110000	Read-Data 	Relative modulation level: 0.00
19:30:55.705777	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:30:56.534052	T00050000	Read-Data 	Application-specific flags: 00000000 0
19:30:56.677059	BC0050000	Read-Ack  	Application-specific flags: 00000000 0
19:30:57.517570	T80190000	Read-Data 	Boiler water temperature: 0.00
19:30:57.661406	BC0192780	Read-Ack  	Boiler water temperature: 39.50
19:30:58.502726	T10010A00	Write-Data	Control setpoint: 10.00
19:30:58.661661	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:30:59.475269	SC: 19:31/7
19:30:59.501277	T80000200	Read-Data 	Status: 00000010 00000000
19:30:59.662267	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:00.009684	Command: SC=19:31/7
19:31:00.603390	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:00.639414	SC: 19:31/7
19:31:00.690438	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:01.493903	T00090000	Read-Data 	Remote override room setpoint: 0.00
19:31:01.519987	R00120000	Read-Data 	CH water pressure: 0.00
19:31:01.653281	B40120182	Read-Ack  	CH water pressure: 1.51
19:31:01.680989	AC0090000	Read-Ack  	Remote override room setpoint: 0.00
19:31:02.493266	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:02.635995	BC0192900	Read-Ack  	Boiler water temperature: 41.00
19:31:03.494190	T10010A00	Write-Data	Control setpoint: 10.00
19:31:03.644408	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:04.480579	T80000200	Read-Data 	Status: 00000010 00000000
19:31:04.639734	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:05.592116	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:05.623722	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:06.480386	T900E6400	Write-Data	Maximum relative modulation level: 100.00
19:31:06.622148	B500E6400	Write-Ack 	Maximum relative modulation level: 100.00
19:31:07.479211	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:07.632238	BC0192A00	Read-Ack  	Boiler water temperature: 42.00
19:31:08.463215	T10010A00	Write-Data	Control setpoint: 10.00
19:31:08.621703	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:09.472870	T80000200	Read-Data 	Status: 00000010 00000000
19:31:09.622260	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:10.599283	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:10.629435	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:11.467591	T10101400	Write-Data	Room setpoint: 20.00
19:31:11.624806	BD0101400	Write-Ack 	Room setpoint: 20.00
19:31:12.451634	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:12.593267	B40192B00	Read-Ack  	Boiler water temperature: 43.00
19:31:13.463278	T10010A00	Write-Data	Control setpoint: 10.00
19:31:13.597544	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:14.436688	T80000200	Read-Data 	Status: 00000010 00000000
19:31:14.595409	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:15.617426	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:15.642469	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:16.435011	T10181535	Write-Data	Room temperature: 21.21
19:31:16.585518	BD0181535	Write-Ack 	Room temperature: 21.21
19:31:17.507003	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:17.592746	B40192D00	Read-Ack  	Boiler water temperature: 45.00
19:31:18.424771	T10010A00	Write-Data	Control setpoint: 10.00
19:31:18.583181	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:19.425339	T80000200	Read-Data 	Status: 00000010 00000000
19:31:19.571141	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:20.597804	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:20.622999	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:21.409239	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:21.568505	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:22.409218	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:22.578621	BC0192E80	Read-Ack  	Boiler water temperature: 46.50
19:31:23.407684	T10010A00	Write-Data	Control setpoint: 10.00
19:31:23.548562	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:24.393678	T80000200	Read-Data 	Status: 00000010 00000000
19:31:24.566121	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:25.600993	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:25.626914	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:26.411179	T00390000	Read-Data 	Max CH water setpoint: 0.00
19:31:26.537131	B40393200	Read-Ack  	Max CH water setpoint: 50.00
19:31:27.394629	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:27.536682	B40193000	Read-Ack  	Boiler water temperature: 48.00
19:31:28.405494	T10010A00	Write-Data	Control setpoint: 10.00
19:31:28.536840	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:29.378400	T80000200	Read-Data 	Status: 00000010 00000000
19:31:29.550407	B4000020A	Read-Ack  	Status: 00000010 00001010
19:31:30.603591	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:30.630474	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:31.381774	T1002010D	Write-Data	Master configuration: 00000001 13
19:31:31.527165	BD002010D	Write-Ack 	Master configuration: 00000001 13
19:31:32.366965	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:32.526605	BC0193200	Read-Ack  	Boiler water temperature: 50.00
19:31:33.371603	T10010A00	Write-Data	Control setpoint: 10.00
19:31:33.533446	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:34.355734	T80000200	Read-Data 	Status: 00000010 00000000
19:31:34.511776	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:35.595181	T80000200	Read-Data 	Status: 00000010 00000000
19:31:35.621935	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:36.356740	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:36.514997	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:37.359681	T80000200	Read-Data 	Status: 00000010 00000000
19:31:37.510432	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:38.344126	T00030000	Read-Data 	Slave configuration: 00000000 0
19:31:38.503297	BC003111D	Read-Ack  	Slave configuration: 00010001 29
19:31:39.354930	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:39.505195	B40193500	Read-Ack  	Boiler water temperature: 53.00
19:31:40.601507	T10010A00	Write-Data	Control setpoint: 10.00
19:31:40.628338	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:41.346977	T80000200	Read-Data 	Status: 00000010 00000000
19:31:41.502481	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:42.340136	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:42.474258	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:43.317496	T00050000	Read-Data 	Application-specific flags: 00000000 0
19:31:43.476604	BC0050000	Read-Ack  	Application-specific flags: 00000000 0
19:31:44.320947	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:44.477793	BC0193680	Read-Ack  	Boiler water temperature: 54.50
19:31:45.596408	T10010A00	Write-Data	Control setpoint: 10.00
19:31:45.632849	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:46.313814	T80000200	Read-Data 	Status: 00000010 00000000
19:31:46.464973	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:47.305501	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:47.462082	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:48.304410	T00090000	Read-Data 	Remote override room setpoint: 0.00
19:31:48.330792	R801A0000	Read-Data 	DHW temperature: 0.00
19:31:48.462510	B401A2400	Read-Ack  	DHW temperature: 36.00
19:31:48.488507	AC0090000	Read-Ack  	Remote override room setpoint: 0.00
19:31:49.305864	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:49.448018	BC0193680	Read-Ack  	Boiler water temperature: 54.50
19:31:50.589443	T10010A00	Write-Data	Control setpoint: 10.00
19:31:50.617101	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:51.289321	T80000200	Read-Data 	Status: 00000010 00000000
19:31:51.450164	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:52.289212	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:52.451533	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:53.292606	T900E6400	Write-Data	Maximum relative modulation level: 100.00
19:31:53.430759	B500E6400	Write-Ack 	Maximum relative modulation level: 100.00
19:31:54.274636	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:54.435133	B40193780	Read-Ack  	Boiler water temperature: 55.50
19:31:55.592803	T10010A00	Write-Data	Control setpoint: 10.00
19:31:55.619238	BD0010A00	Write-Ack 	Control setpoint: 10.00
19:31:56.276816	T80000200	Read-Data 	Status: 00000010 00000000
19:31:56.417583	B40000200	Read-Ack  	Status: 00000010 00000000
19:31:57.275190	T00110000	Read-Data 	Relative modulation level: 0.00
19:31:57.417967	BC0110000	Read-Ack  	Relative modulation level: 0.00
19:31:58.262461	T10101400	Write-Data	Room setpoint: 20.00
19:31:58.426963	BD0101400	Write-Ack 	Room setpoint: 20.00
19:31:59.250736	T80190000	Read-Data 	Boiler water temperature: 0.00
19:31:59.412503	B40193880	Read-Ack  	Boiler water temperature: 56.50
19:31:59.499183	SC: 19:32/7````