Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Rev C smoke reported on auto calibrate etb #65

Open
rusefillc opened this issue Sep 24, 2022 · 6 comments
Open

Rev C smoke reported on auto calibrate etb #65

rusefillc opened this issue Sep 24, 2022 · 6 comments
Assignees

Comments

@rusefillc
Copy link
Contributor

No description provided.

@rusefillc
Copy link
Contributor Author

See rusefi/rusefi#4579

@rusefillc
Copy link
Contributor Author

I can think of the following scenario:

Firmware sets stepperDcInvertedPins to 'true' on start up

If one restores a tune from older unit it could be overwriting stepperDcInvertedPins to false. Until reboot stepperDcInvertedPins value would stay false. That could cause smoke.

@ElDominio
Copy link
Collaborator

image

@rusefillc
Copy link
Contributor Author

@ElDominio good to close this?

@rusefillc
Copy link
Contributor Author

@ElDominio ?

@ElDominio
Copy link
Collaborator

This never happened again, I keep selling with no issue. Even the smoke board was fine