Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Ideas #39

Open
mimquadrat opened this issue May 21, 2016 · 6 comments
Open

Ideas #39

mimquadrat opened this issue May 21, 2016 · 6 comments

Comments

@mimquadrat
Copy link

Again me :) (the guy from Germany)
I have some ideas - perhaps you find something for you to realize:

@rcrum003
Copy link
Owner

Love the idea of the push service - What threshold should we use to send the alert? More than 10% of the daily counter volume?

@mimquadrat
Copy link
Author

10 maybe 20%
Or a dramatical drop of the weight! When the bees leave the hive is lighter...

Mit besten Grüßen

Martin Mehringer

Am 21.05.2016 um 16:15 schrieb Ryan [email protected]:

Love the idea of the push service - What threshold should we use to send the alert? More than 10% of the daily counter volume?


You are receiving this because you authored the thread.
Reply to this email directly or view it on GitHub

@NapaOgden
Copy link

I'd like to see a settable alarm entry for weight loss. About 1.5 pounds
over 20 minutes seems like a good start point. Need at least two 5 min
samples to trigger alarm, discrimination from noise etc.
My 2cents worth...
On May 21, 2016 9:29 AM, "mimquadrat" [email protected] wrote:

10 maybe 20%
Or a dramatical drop of the weight! When the bees leave the hive is
lighter...

Mit besten Grüßen

Martin Mehringer

Am 21.05.2016 um 16:15 schrieb Ryan [email protected]:

Love the idea of the push service - What threshold should we use to send
the alert? More than 10% of the daily counter volume?


You are receiving this because you authored the thread.
Reply to this email directly or view it on GitHub


You are receiving this because you are subscribed to this thread.
Reply to this email directly or view it on GitHub
#39 (comment)

@nanderson77
Copy link

If you asked every person, you’d probably get a different answer. For push notifications, there are typically setpoints and a time delays, so if you were to take the same approach for the interesting variables, allow a setpoint and a delay timer to be user configured

I think weight’s going to be a problem unless there’s something like the nasa weight filter the .net website has… adding or removing supers would likely always trigger a notification.

Nate Anderson

Home 763-537-4193

Cell 763-688-0432

Skype 763-634-0115 (nanderson777)

From: NapaOgden [mailto:[email protected]]
Sent: Saturday, May 21, 2016 1:20 PM
To: rcrum003/HiveControl [email protected]
Subject: Re: [rcrum003/HiveControl] Ideas (#39)

I'd like to see a settable alarm entry for weight loss. About 1.5 pounds
over 20 minutes seems like a good start point. Need at least two 5 min
samples to trigger alarm, discrimination from noise etc.
My 2cents worth...
On May 21, 2016 9:29 AM, "mimquadrat" <[email protected] mailto:[email protected] > wrote:

10 maybe 20%
Or a dramatical drop of the weight! When the bees leave the hive is
lighter...

Mit besten Grüßen

Martin Mehringer

Am 21.05.2016 um 16:15 schrieb Ryan <[email protected] mailto:[email protected] >:

Love the idea of the push service - What threshold should we use to send
the alert? More than 10% of the daily counter volume?


You are receiving this because you authored the thread.
Reply to this email directly or view it on GitHub


You are receiving this because you are subscribed to this thread.
Reply to this email directly or view it on GitHub
#39 (comment)


You are receiving this because you are subscribed to this thread.
Reply to this email directly or view it on GitHub #39 (comment) https://github.com/notifications/beacon/AP2FaU3JefKUpaA9QsHVU5bxiYJkQNM7ks5qD0zsgaJpZM4IjvcN.gif

@NapaOgden
Copy link

If one wanted to eliminate weight change alarms when working hives (not a problem, good test) one could simply disable the sensor then reenable after work has been done. Alternatively if a super or other component were added/removed use the net weight and adjust components to compensate.

@NapaOgden
Copy link

Maybe off topic, please add slope & intercept and reading when "local hive" temperature, humidity sensors are employed.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

4 participants