SmartDataCenter (SDC) is an open-source cloud management platform, optimized to deliver next generation, container-based, service-oriented infrastructure across one or more data centers. With an emphasis on ease of installation and operation, SDC is proven at scale: it is the software that runs the Joyent public cloud and powers private clouds at organizations of all size and industry.
This repository provides documentation for the overall SDC project and pointers to the other repositories that make up a complete SDC deployment. See the repository list.
Report bugs and request features using GitHub Issues. For additional resources, you can visit the Joyent Developer Center.
A SmartDataCenter installation consists of two or more servers. All servers run SmartOS. One server acts as the management server, the headnode, which houses the initial set of core services that drive SDC. The remainder are compute nodes (CNs) which run instances (virtual machines).
SDC features:
- SmartOS zones provides high performance container virtualization. KVM support on top of zones means secure full Linux and Windows guest OS support.
- RESTful API and CLI tooling for customer self-service
- Complete operator portal (web app)
- Robust and observable service oriented architecture (implemented primarily in Node.js)
- Automated USB key installation
SDC consists of the following components:
- A public API for provisioning and managing instances (virtual machines), networks, users, images, etc.
- An operator portal
- A set of private APIs
- Agents running in the global zone of CNs for management and monitoring
For more details, see:
- The Overview of SmartDataCenter 7 in the Joyent customer documentation.
- SmartDataCenter Architecture for overall architecture.
- SmartDataCenter Reference for an overview of each component.
Community discussion about SmartDataCenter happens in two main places:
-
The sdc-discuss mailing list. Once you subscribe to the list, you can send mail to the list address: [email protected]. The mailing list archives are also available on the web.
-
In the #smartos IRC channel on the Freenode IRC network.
You can also follow @SmartDataCenter on Twitter for updates.
An easy way to try SmartDataCenter is by downloading a Cloud on a Laptop (CoaL) build. This is a VMware virtual appliance providing a full SDC headnode for development and testing.
The minimum requirements, practically speaking, for a good CoaL experience is a Mac with at least 16 GB RAM and an SSD. Currently, almost all team members using CoaL are on Macs with VMware Fusion. Vmware Workstation for Linux is used by a few in the community. VMware Workstation for Windows should work, but has not recently been tested.
See CoaL Setup for a thorough walkthrough including updating CoaL and enabling provisioning on the headnode.
-
Start the download of the latest CoaL build. The tarball is approximately 2 GB.
curl -C - -O https://us-east.manta.joyent.com/Joyent_Dev/public/SmartDataCenter/coal-latest.tgz
-
Install VMware, if you haven't already.
- Mac: VMware Fusion 5 or 7.
- Windows or Linux: VMware Workstation.
-
Configure VMware virtual networks for CoaL's "external" and "admin" networks. This is a one time configuration for a VMware installation.
-
Launch VMware at least once after installing VMware.
-
Run SDC set up script for VMware:
-
Mac:
curl -s https://raw.githubusercontent.com/joyent/sdc/master/tools/coal-mac-vmware-setup | sudo bash
-
Linux:
curl -s https://raw.githubusercontent.com/joyent/sdc/master/tools/coal-linux-vmware-setup | sudo bash
-
Windows:
Download https://raw.githubusercontent.com/joyent/sdc/master/tools/coal-windows-vmware-setup.bat Run coal-windows-vmware-setup.bat
-
-
-
Unpack the CoaL build that you downloaded in step 1.
-
Mac:
$ tar -zxvf coal-latest.tgz x root.password.20140911t161518z x coal-master-20140911T194415Z-g1a445f5-4gb.vmwarevm/ x coal-master-20140911T194415Z-g1a445f5-4gb.vmwarevm/USB-headnode.vmx x coal-master-20140911T194415Z-g1a445f5-4gb.vmwarevm/zpool.vmdk x coal-master-20140911T194415Z-g1a445f5-4gb.vmwarevm/USB-headnode.vmdk x coal-master-20140911T194415Z-g1a445f5-4gb.vmwarevm/4gb.img ...
-
-
Start VMware and load the appliance.
-
Mac: 'open'ing the folder will start VMware and "open and run" the vm:
open coal-<branch>-<build_date_time>-<git_sha1_hash>-4gb.vmwarevm
-
-
Boot the headnode.
When you are prompted with the GRUB menu press the "down" arrow.
-
Press the down arrow key to highlight "Live 64-bit".
-
Press 'c' to go to the command line for GRUB.
By default, the OS will redirect the console to ttyb which is fine for production but needs to be changed for CoaL. While in the command line:
grub> variable os_console vga
-
Press enter.
-
Press esc to get back to the GRUB menu.
-
Boot "Live 64-bit" by pressing enter.
-
Configure the headnode.
Use the following table to configure your CoaL with settings that are fine for development.
If you make a mistake while entering the configuration you can restart the VMware virtual machine. Also, as the onscreen instructions describe, the last step in configuration allows editing the resulting configuration file.
Setting | Value | Notes |
---|---|---|
Instructions | ↵ | |
Company Name | Clavius | Can substitute with your choice. |
Region of Datacenter | orbit | Can substitute with your choice. |
Name of Datacenter | coal-1 | (Availability zone.) Can substitute with your choice. |
Location of DataCenter | Moon, Earth | Can substitute with your choice. |
Instructions | ↵ | |
'admin' interface | 2 | The second NIC is set up as the admin network by the CoaL networking script |
(admin) headnode IP address | 10.99.99.7 | Must use this value. |
(admin) headnode netmask: | ↵ | Use the default. |
(admin) Zone's starting IP address: | ↵ | Use the default. |
Add external network now? (Y/n) | Y | Must use this value. |
'external' interface | 1 | The first NIC is set up as the external network by the CoaL networking script |
(external) headnode IP address | 10.88.88.200 | Must use this value. |
(external) headnode netmask: | ↵ | Use the default. |
(external) gateway IP address: | 10.88.88.2 | Must use this value. |
(external) network VLAN ID | ↵ | Use default. The external network is not on a VLAN in CoaL |
Starting Provisionable IP address for external Network | ↵ | Use the default. |
Ending Provisionable IP address for external Network | ↵ | Use the default. |
Default gateway IP address: | ↵ | Use the default. |
Primary DNS Server | ↵ | Use the default. |
Secondary DNS Server | ↵ | Use the default. |
Head node domain name | example.com | Can substitute with your choice. |
DNS Search Domain | example.com | Can substitute with your choice. |
NTP Server IP Address | ↵ | Use the default. |
"root" password | rootpass | Can substitute with your choice. |
Confirm "root" password | ||
"admin" password | adminpass1 | Can substitute with your choice. |
Confirm "admin" password | ||
Administrator's email | ↵ | Use the default. |
Support email | ↵ | Use the default. |
Confirm password | ||
Enable telemetry | "true" or "false" | Can use your choice |
Verify Configuration | ||
Verify Configuration Again |
- CoaL will now install based on the configuration parameters entered above. Installation has been observed to take up to 20 minutes, particularly if slow laptop HDD.
After setup is complete you should be able to SSH into your CoaL on the "admin" network. Example:
ssh [email protected] # password 'rootpass'
For just a taste run svcs
to see running SMF
services.
Run vmadm list
to see a list of current VMs (SmartOS
zones). Each SDC service runs in
its own zone. See the Joyent customer documentation.
As mentioned previously, see CoaL Setup for a thorough walkthrough.
A SmartDataCenter server runs SmartOS which is a live image. This means that it boots from a USB flash drive (key). a physical USB key, inserting the key and booting the server from that key. To install SDC, first obtain the latest release USB build.
For SDC development only, the minimum server hardware is:
- 8 GB USB flash drive
- Intel Processors with VT-x and EPT support (all Xeon since Nehalem)
- 16 GB RAM
- 6 GB available storage
Hardware RAID is not recommended. SDC will lay down a ZFS ZPOOL across all available disks on install. You'll want much more storage if you're working with images and instances.
If setting up a SmartDataCenter pilot then you'll want to review the Minimum Requirements and Installation Prerequisites which include IPMI and at least 10 gigabit Ethernet. The supported hardware components for SmartOS are described in the SmartOS Hardware Requirements. Joyent certified hardware for SmartDataCenter are all in the Joyent Manufacturing Database.
To install SDC, first download the latest release image:
curl -C - -O https://us-east.manta.joyent.com/Joyent_Dev/public/SmartDataCenter/usb-latest.tgz
Once you have downloaded the latest release image, you will need to write it to a USB key, boot the headnode server using the USB key, and follow the install prompts. See the the Joyent customer documentation "installing SDC 7" and "install checklist" for information.
After installation, you will probably want to perform some additional configuration. The most common of these include:
- Adding external nics to the imgapi and adminui zones to give them internet access. This enables simple import of VM images.
- Provision a CloudAPI zone to allow users to create and administer their VMs without an operator.
See the post-installation configuration documentation for the complete list.
SDC is composed of several pre-built components:
- A SmartOS platform image. This is a slightly customized build of vanilla SmartOS for SDC.
- Virtual machine images for SDC services (e.g. imgapi, vmapi, adminui), which are provisioned as VMs at install time.
- Agents bundled into a single package installed into the global zone of each compute node.
Each component is built separately and then all are combined into CoaL and USB
builds (see the preceding sections) via the sdc-headnode
repository. The built components are
typically stored in a Manta object store,
e.g. Joyent's public Manta,
and pulled from there. For example, Joyent's builds push to
/Joyent_Dev/public/builds
in Joyent's public Manta in us-east-1
(https://us-east.manta.joyent.com/).
You can build your own CoaL and USB images on Mac or SmartOS (see the sdc-headnode README). However, all other SDC components must be built using a running SDC (e.g. on the Joyent Cloud or in a local CoaL). See the building document for details on building each of the SDC components.
To report bugs or request features, submit issues here on GitHub, joyent/sdc/issues. If you're contributing code, make pull requests to the appropriate repositories (see the repo overview). If you're contributing something substantial, you should first contact developers on the sdc-discuss mailing list (subscribe, archives).
For support of Joyent products and services, please contact Joyent customer support instead.
SDC repositories follow the Joyent Engineering Guidelines. Notably:
- The #master branch should be first-customer-ship (FCS) quality at all times. Don't push anything until it's tested.
- All repositories should be
make check
clean at all times. - All repositories should have tests that run cleanly at all times.
make check
checks both JavaScript style and lint. Style is checked with
jsstyle. The specific style rules are
somewhat repo-specific. Style is somewhat repo-specific. See the jsstyle
configuration file or JSSTYLE_FLAGS
in Makefiles in each repo for exceptions
to the default jsstyle rules.
Lint is checked with javascriptlint. (Don't conflate lint with style! There are gray areas, but generally speaking, style rules are arbitrary, while lint warnings identify potentially broken code. Repos sometimes have repo-specific lint rules -- look for "tools/jsl.web.conf" and "tools/jsl.node.conf" for per-repo exceptions to the default rules.
SmartDataCenter is very opinionated about how to architect a cloud. These opinions are the result of many years of deploying and debugging the Joyent public cloud. Design principles include the following:
- A VM's primary storage should be local disk, not over the network -- this avoids difficult to debug performance pathologies.
- Communication between internal APIs should occur in its own control plane (network) that is separate from the customer networks. Avoid communicating over the open Internet if possible.
- A provisioned VM should rely as little as possible on SDC services outside of the operating system for its normal operation.
- Installation and operation should require as little human intervention as possible.
The goals behind the design of SDC services include:
- All parts of the stack should be observable.
- The state of the running service should be simple to obtain.
- The internals of the system should make it straightfoward to debug from a core file (from a crash or taken from a running process using gcore(1)).
- Services should be RESTful and accept JSON unless there is a compelling reason otherwise.
- Services should avoid keeping state and should not assume that there is only one instance of that service running. This allows multiple instances of a service to be provisioned for high availability.
- Node.js and C should be used for new services.
SmartDataCenter uses SmartOS as the host operating system. The SmartOS hypervisor provides both SmartOS zone (container) and
Joyent's open-source Manta project is an HTTP-based object store with built-in support to run arbitrary programs on data at rest (i.e., without copying data out of the object store). Manta runs on and integrates with SmartDataCenter.
SmartDataCenter is licensed under the Mozilla Public License version 2.0. See the file LICENSE. SmartOS is licensed separately.