Replace "0"s made in the unwrapping output with the original wrapped phase value #11

Closed
2 tasks done
scottstanie opened this issue Oct 5, 2023 · 1 comment
Closed
2 tasks done

Comments

@scottstanie
Copy link
Contributor

scottstanie commented Oct 5, 2023

Since we don't want to make it impossible for a better unwrapping job, we'd rather keep the original wrapped phase where the unwrapper gave up.

  • Make sure we reset all data originally in the interferogram (both masked for unwrapping, and badly unwrapped areas)
  • Ensure that the edges haven't gotten slightly off of the nodata value. Every frame should be nans around the outside, and something nonzero inside
  • Make sure we have some clear mask layer which says "we think you should probably ignore these areas"
@scottstanie
Copy link
Contributor Author

Currently working for both snaphu and spurt (after this dolphin PR). Can reopen new issue if a new problem is discovered with it