-
Notifications
You must be signed in to change notification settings - Fork 0
/
hm_fbh.ccu.tmpl
209 lines (195 loc) · 8.81 KB
/
hm_fbh.ccu.tmpl
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
! HM_FBH Version 5 Steuerung Fussbodenheizung
!
! Bei Versionswechsel auch sLogPrefix anpassen
!
! https://github.com/mgoppold/hm_fbh.git
! bzw.
! https://github.com/mgoppold/hm_fbh/releases/tag/4
!
! Script zur Steuerung einer Fussbodenheizung
! Temperaturen und Zeiten werden im Thermostat definiert
!
! genutzte Systemvariablen:
!
! Heizperiode = bool
! HM_FBH_DEBUG = integer 0,1,2,3
! HM_FBH_TIMEOUT = integer Zeit in Sekunden bevor An-/Ausgeschalten wird
!
! XX_Temp_Last = real Temp WZ beim letzten Programmlauf z.B. 21.5
! {WZ,KU,FU,BZ,SZ,GZ,AZ}_Temp_Last
!
! XX_Temp_Offset = real Temp Offset beim dem die Heizung vor Erreichen der Solltemperatur ausgeschalten wird (-10 .. 10)
! {WZ,KU,FU,BZ,SZ,GZ,AZ}_Temp_Offset
!
! genutze Objekte
! CUxD.CUX2801001 ! zum Logging (siehe CUxD Doku Seite 92 ff Kap. 5.8.2 System.Exec)
! TempRegler Typ HM-TC-IT-WM-W-EU
! Switch Typ HM-LC-Sw4-DR
!
! Programm: HM_FBH
!
! Bedingung: Wenn...
! WZ_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! ODER
! AZ_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! ODER
! BZ_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! ODER
! FU_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! ODER
! GZ_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! ODER
! KU_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! ODER
! SZ_Thermostat:1 bei Temperatur im Wertebereich von 5.00° C bis kleiner 30.00° C bei Aktualisierung auslösen
! UND
! Heizperiode ist wahr
! Aktivität: Dann...
! [x] Vor dem Ausführen alle laufenden Verzögerungen für diese Aktivitäten beenden (z.B. Retriggern).
! dieses Script
integer idebug = 0; ! Debug Infos /tmp/devlog.txt - sollte immer auf 0 oder 1 sein, nur bei Problemen auf 2,3 (wird duch HM_FBH_DEBUG überschrieben)
string sLogPrefix = "HM_FBH_5:";
string sSetTemp; ! String Typ.SERIAL:2.SET_TEMPERATURE
string sActTemp; ! String Typ.SERIAL:2.ACTUAL_TEMPERATURE"
string sSwitchState; ! String Typ.SERIAL.REF des Switches
string sSysVarTempLast; ! String Systemvariable auf welcher sich die letzte Temperatur gemerkt wird
string sSysVarTempOffset; ! String Systemvariable auf welcher sich die letzte Temperatur gemerkt wird
integer itimeout = 1800; ! 30min Mindestzeit die geheizt wird (wird durch HM_FBH_TIMEOUT überschrieben)
real rakt = -1.0; ! aktuelle Temperatur
real rsoll = -1.0; ! Solltemperatur im Raumthermostat (Regler).
object osrc = dom.GetObject("$src$");
object olog = dom.GetObject("CUxD.CUX2801001:1.LOGIT");
if ( dom.GetObject('HM_FBH_DEBUG') ) {
idebug = dom.GetObject('HM_FBH_DEBUG').Value();
}
if ( dom.GetObject('HM_FBH_TIMEOUT') ) {
itimeout = dom.GetObject('HM_FBH_TIMEOUT').Value();
}
if ( olog ) {
if ((idebug>3) && osrc) {
olog.State(sLogPrefix#"Programm HM_FBH ist aktiv");
}
}
else {
idebug = 0;
}
if (osrc) {
! olog.State(sLogPrefix#"ausloeser Name="#osrc.Name()#" ID="#osrc.ID()#" TypeName="#osrc.TypeName()#" Value="#osrc.Value());
string stemp = osrc.Name();
string sserial = stemp.StrValueByIndex(":", 0);
sSetTemp = sserial#":2.SET_TEMPERATURE";
sActTemp = sserial#":2.ACTUAL_TEMPERATURE";
if ( sserial == "BidCos-RF.MEQ1230005" ) {
sSwitchState = "BidCos-RF.MEQ1230009"# ":1.STATE"; ! XX_Heizung_UG:WZ
sSysVarTempLast = "WZ_Temp_Last";
sSysVarTempOffset = "WZ_Temp_Offset";
sLogPrefix = sLogPrefix#"WZ:";
}
if ( sserial == "BidCos-RF.MEQ1230004" ) {
sSwitchState = "BidCos-RF.MEQ1230009"# ":2.STATE"; ! XX_Heizung_UG:KU
sSysVarTempLast = "KU_Temp_Last";
sSysVarTempOffset = "KU_Temp_Offset";
sLogPrefix = sLogPrefix#"KU:";
}
if ( sserial == "BidCos-RF.MEQ1230002" ) {
sSwitchState = "BidCos-RF.MEQ1230009"# ":3.STATE"; ! XX_Heizung_UG:FU
sSysVarTempLast = "FU_Temp_Last";
sSysVarTempOffset = "FU_Temp_Offset";
sLogPrefix = sLogPrefix#"FU:";
}
if ( sserial == "BidCos-RF.MEQ1230007" ) {
sSwitchState = "BidCos-RF.MEQ1230008"# ":1.STATE"; ! XX_Heizung_OG:BZ
sSysVarTempLast = "BZ_Temp_Last";
sSysVarTempOffset = "BZ_Temp_Offset";
sLogPrefix = sLogPrefix#"BZ:";
}
if ( sserial == "BidCos-RF.MEQ1230003" ) {
sSwitchState = "BidCos-RF.MEQ1230008"# ":2.STATE"; ! XX_Heizung_OG:SZ
sSysVarTempLast = "SZ_Temp_Last";
sSysVarTempOffset = "SZ_Temp_Offset";
sLogPrefix = sLogPrefix#"SZ:";
}
if ( sserial == "BidCos-RF.MEQ1230006" ) {
sSwitchState = "BidCos-RF.MEQ1230008"# ":3.STATE"; ! XX_Heizung_OG:GZ
sSysVarTempLast = "GZ_Temp_Last";
sSysVarTempOffset = "GZ_Temp_Offset";
sLogPrefix = sLogPrefix#"GZ:";
}
if ( sserial == "BidCos-RF.MEQ1230001" ) {
sSwitchState = "BidCos-RF.MEQ1230008"# ":4.STATE"; ! XX_Heizung_OG:AZ
sSysVarTempLast = "AZ_Temp_Last";
sSysVarTempOffset = "AZ_Temp_Offset";
sLogPrefix = sLogPrefix#"AZ:";
}
! olog.State(sLogPrefix#" zugeh ActTemp="#sActTemp#" SetTemp="#sSetTemp#" Switch="#sSwitchState#" SysVar="#sSysVarTempLast);
if (dom.GetObject('Heizperiode').State()) {
object oSwitch = dom.GetObject( sSwitchState ); ! Datenobjekt für XX_Heizung_UG:WZ
time tnow = system.Date("%Y-%m-%d %H:%M:%S").ToTime(); ! aktuelle Zeit
time ts_timestamp = oSwitch.Timestamp();
time tsw = ts_timestamp.ToInteger();
integer isdiff = tnow.ToInteger() - tsw.ToInteger(); ! Sekunden seit letztem Statuswechsel
if (isdiff < itimeout) {
if (idebug>1) {
olog.State(sLogPrefix#"Zeit fuer weiteren Statuswechsel noch nicht erreicht ("#isdiff#"<"#itimeout#")");
}
}
else {
rsoll = dom.GetObject( sSetTemp ).Value(); ! Solltemperatur auslesen
rakt = dom.GetObject( sActTemp ).Value(); ! aktuelle auslesen
if (rsoll >= 0 && rakt >= 0 ) { ! Wenn sSetTemp/sActTemp ausgelesen werden konnten
string sstate = "konstant";
real roffset = dom.GetObject( sSysVarTempOffset ).Value(); ! SystemVar XX_Temp_Offset auslesen
object olast = dom.GetObject( sSysVarTempLast ); ! SystemVar XX_Temp_Last auslesen
real rlast = olast.Value();
integer itempdiff = (( rakt * 10 ).ToInteger() - ( rlast * 10 ).ToInteger()); ! eine Nachkommastelle reicht aus
real rsolloffset = rsoll+roffset;
if ( itempdiff < 0 ) {
sstate = "fallend";
}
if ( itempdiff > 0 ) {
sstate = "steigend";
}
if (idebug>0) {
olog.State(sLogPrefix#"Soll=" # rsoll # "|Soll+O="#rsolloffset#"|Ist=" # rakt # "|Last=" # rlast # "|Status=" # oSwitch.State() # "|t=" # isdiff # "s|" # sstate);
}
if ( oSwitch.State() ) { ! Heizung ist gerade an
! Wenn aktuelle Temperatur+Offset über Solltemperatur liegt
if ( rakt >= rsolloffset ) {
if (idebug>0) {
olog.State(sLogPrefix#"schalte Heizung aus");
}
oSwitch.State(false);
}
else {
if (idebug>0) {
olog.State(sLogPrefix#"Heizung bleibt an");
}
}
}
else { ! Heizung ist aus
if ( (rakt < rsoll) && ( itempdiff <= 0 )) {
if (idebug>0) {
olog.State(sLogPrefix#"schalte Heizung an");
}
oSwitch.State(true);
}
else {
if (idebug>0) {
if ( rakt > rsoll ) {
olog.State(sLogPrefix#"Heizung bleibt aus (weil Ist>=Soll)");
}
else {
olog.State(sLogPrefix#"Heizung bleibt aus (weil Temp noch steigt)");
}
}
}
} ! Heizung an oder aus
olast.State(rakt); ! merke die aktuelle Temperatur auf XX_Temp_Last
}
else { ! Thermostat antwortet nicht
dom.GetObject("CUxD.CUX2801001:1.CMD_EXEC").State("logger -t script -p user.debug Raumthermostat " # osrc.Name() # " antwortet nicht!");
dom.GetObject("CUxD.CUX2801001:1.CMD_RUNS").State(1);
}
} ! else isdiff < itimeout
} ! Heizperiode
} ! ausloesendes Objekt ist definiert