[ecdsa] Try increasing sampling rate with updated firmware #107

Open
vogelpi opened this issue Dec 19, 2022 · 0 comments
Open

[ecdsa] Try increasing sampling rate with updated firmware #107

vogelpi opened this issue Dec 19, 2022 · 0 comments

Comments

@vogelpi
Copy link
Collaborator

vogelpi commented Dec 19, 2022

Currently, we're sampling with 50 MHz and the target is running at ~5 MHz for ECDSA captures to keep a 10x oversampling ratio (some of this work is not yet in the repo). Above 50 MHz it seems the synchronization between multiple runs/segments is lost. We should re-investigate this with an updated Husky firmware.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment