@hakk2020 can you also check your logs? ( http:///config/logs or https:// ) and search for "sunpower". If there isn't much in there you can get even more detailed logs in the integration page (you'll probably want to filter those out if you capture them! In the mean time I will look at these in more detail. |
Thank you for responding so quickly! Coincidentally, Sunpower sent a tech out to troubleshoot one of my systems due to not reporting production. He said he replaced one of the CTs and upgraded the firmware, after which both systems started reporting to Home Assistant. However, a day later one of them stopped again. Looking at the Sunpower App, both systems are online and reporting. When I try to get to the one that's not reporting to Home Assistant, I get '403 Forbidden'. I wonder if this is an issue that's related to my PVS and not the integration. I'm attaching the integration log, in case you'd like to review. |
Just an update, I rebooted the PVS twice. After the second reboot, it started reporting properly. |
When I run into this problem I reload the integration in HA. |
Thank you for the suggestion! Unfortunately, I tried reloading the integration, removing/adding the two systems. Nothing seems to stick. I get both systems to work for a few hours and then one of them stops reporting. It's not a networking issue, because I can access both systems via IP. If I keep only one system in the integration, it seems to work consistently. As far as I can tell, my problem exists only when the two systems are present in the integration. |
You mentioned "When I try to get to the one that's not reporting to Home Assistant, I get '403 Forbidden'. I wonder if this is an issue that's related to my PVS and not the integration" I'm concerned that sunpower might have disabled this endpoint after some period of uptime (it would still allow installers to use it - which is its intended usecase). I'd love to get more info to be sure: Can you
|
Hi, sorry for the delayed response. I appreciate your help. The main thing at the moment is that the 403 error was resolved after rebooting the PVS a couple of times. At present, I can access both my PVS systems using the DeviceList URL. Please see below for answers to your questions.
Mini router details: https://www.gl-inet.com/products/gl-mt300n-v2/ |
Apologies this thread got dropped. Is this still an issue? This integration won't be able to solve a 403 (if its a 403 for curl, it'll be a 403 for the integration) At this point I don't think I've seen similar reports so I don't think its caused by a newer firmware or other people would be seeing it. I would really suspect something along the path isn't behaving correctly (not HA, nor the PVS). To debug I would tcpdump the lan between the router and the PVS management interface and ensure 1) there is traffic there, 2) the PVS is really responding with a 403. |
Hi, I started experiencing issues getting data into Home Assistant from either one or both of my PVS units. Running this in the Browser shows all the details http:///cgi-bin/dl_cgi?Command=DeviceList every time and there are no networking issues I can see. Below is the output of the DevileList command from the PVS that's currently nor reporting in HA. I hope you can help me figure out the issue.
{
"devices": [
{
"DETAIL": "detail",
"STATE": "working",
"STATEDESCR": "Working",
"SERIAL": "ZT230585000549F2221",
"MODEL": "PV Supervisor PVS6",
"HWVER": "6.03",
"SWVER": "2023.3, Build 61410",
"DEVICE_TYPE": "PVS",
"DATATIME": "2024,06,04,22,55,00",
"dl_err_count": "0",
"dl_comm_err": "141",
"dl_skipped_scans": "0",
"dl_scan_time": "1",
"dl_untransmitted": "660904",
"dl_uptime": "88591",
"dl_cpu_load": "0.50",
"dl_mem_used": "78608",
"dl_flash_avail": "63019",
"panid": 1411269642,
"CURTIME": "2024,06,04,22,57,14"
},
{
"ISDETAIL": true,
"SERIAL": "PVS6M23052221p",
"TYPE": "PVS5-METER-P",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "PVS6M0400p",
"DESCR": "Power Meter PVS6M23052221p",
"DEVICE_TYPE": "Power Meter",
"interface": "mime",
"production_subtype_enum": "GROSS_PRODUCTION_SITE",
"subtype": "GROSS_PRODUCTION_SITE",
"SWVER": "3000",
"PORT": "",
"DATATIME": "2024,06,04,22,57,13",
"ct_scl_fctr": "50",
"net_ltea_3phsum_kwh": "2841.35",
"p_3phsum_kw": "0.3833",
"q_3phsum_kvar": "0.1575",
"s_3phsum_kva": "0.46",
"tot_pf_rto": "0.8363",
"freq_hz": "60",
"i_a": "1.9146",
"v12_v": "240.2844",
"CAL0": "50",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,14"
},
{
"ISDETAIL": true,
"SERIAL": "PVS6M23052221c",
"TYPE": "PVS5-METER-C",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "PVS6M0400c",
"DESCR": "Power Meter PVS6M23052221c",
"DEVICE_TYPE": "Power Meter",
"interface": "mime",
"subtype": "NOT_USED",
"SWVER": "3000",
"PORT": "",
"DATATIME": "2024,06,04,22,57,13",
"ct_scl_fctr": "100",
"net_ltea_3phsum_kwh": "0",
"p_3phsum_kw": "0",
"q_3phsum_kvar": "0",
"s_3phsum_kva": "0",
"tot_pf_rto": "0",
"freq_hz": "60",
"i1_a": "0",
"i2_a": "0",
"v1n_v": "120.3094",
"v2n_v": "119.9756",
"v12_v": "240.2844",
"p1_kw": "0",
"p2_kw": "0",
"neg_ltea_3phsum_kwh": "0",
"pos_ltea_3phsum_kwh": "0",
"CAL0": "100",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,14"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247100156",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247100156",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,56,58",
"ltea_3phsum_kwh": "351.2553",
"p_3phsum_kw": "0.0463",
"vln_3phavg_v": "242.37",
"i_3phsum_a": "0.19",
"p_mppt1_kw": "0.049",
"v_mppt1_v": "35.78",
"i_mppt1_a": "1.37",
"t_htsnk_degc": "30",
"freq_hz": "60.01",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,14"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247100777",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247100777",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,56,58",
"ltea_3phsum_kwh": "360.2006",
"p_3phsum_kw": "0.0469",
"vln_3phavg_v": "241.38",
"i_3phsum_a": "0.19",
"p_mppt1_kw": "0.0497",
"v_mppt1_v": "35.77",
"i_mppt1_a": "1.39",
"t_htsnk_degc": "30",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,15"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247101126",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247101126",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,56,58",
"ltea_3phsum_kwh": "353.2716",
"p_3phsum_kw": "0.0458",
"vln_3phavg_v": "241.45",
"i_3phsum_a": "0.19",
"p_mppt1_kw": "0.0492",
"v_mppt1_v": "35.79",
"i_mppt1_a": "1.37",
"t_htsnk_degc": "31",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,15"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247106541",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247106541",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,56,58",
"ltea_3phsum_kwh": "346.2702",
"p_3phsum_kw": "0.0457",
"vln_3phavg_v": "241.72",
"i_3phsum_a": "0.18",
"p_mppt1_kw": "0.0493",
"v_mppt1_v": "35.6",
"i_mppt1_a": "1.38",
"t_htsnk_degc": "30",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,15"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247106596",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247106596",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,56,58",
"ltea_3phsum_kwh": "355.6719",
"p_3phsum_kw": "0.0462",
"vln_3phavg_v": "241.32",
"i_3phsum_a": "0.19",
"p_mppt1_kw": "0.0498",
"v_mppt1_v": "35.7",
"i_mppt1_a": "1.39",
"t_htsnk_degc": "31",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,15"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247113775",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247113775",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,57,13",
"ltea_3phsum_kwh": "344.5262",
"p_3phsum_kw": "0.0455",
"vln_3phavg_v": "242.48",
"i_3phsum_a": "0.18",
"p_mppt1_kw": "0.049",
"v_mppt1_v": "35.8",
"i_mppt1_a": "1.36",
"t_htsnk_degc": "30",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,15"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247114265",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247114265",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,57,13",
"ltea_3phsum_kwh": "344.6895",
"p_3phsum_kw": "0.0454",
"vln_3phavg_v": "242.05",
"i_3phsum_a": "0.18",
"p_mppt1_kw": "0.0498",
"v_mppt1_v": "35.86",
"i_mppt1_a": "1.39",
"t_htsnk_degc": "30",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,15"
},
{
"ISDETAIL": true,
"SERIAL": "E00122247114391",
"TYPE": "SOLARBRIDGE",
"STATE": "working",
"STATEDESCR": "Working",
"MODEL": "AC_Module_Type_H",
"DESCR": "Inverter E00122247114391",
"DEVICE_TYPE": "Inverter",
"hw_version": "4407",
"interface": "mime",
"module_serial": "",
"PANEL": "WAAREE-AKRA-400W",
"slave": 0,
"SWVER": "4.21.4",
"PORT": "",
"MOD_SN": "",
"NMPLT_SKU": "",
"DATATIME": "2024,06,04,22,57,13",
"ltea_3phsum_kwh": "350.7921",
"p_3phsum_kw": "0.046",
"vln_3phavg_v": "241.91",
"i_3phsum_a": "0.19",
"p_mppt1_kw": "0.0507",
"v_mppt1_v": "35.84",
"i_mppt1_a": "1.41",
"t_htsnk_degc": "31",
"freq_hz": "60",
"stat_ind": "0",
"origin": "data_logger",
"OPERATION": "noop",
"CURTIME": "2024,06,04,22,57,16"
}
],
"result": "succeed"
}
The text was updated successfully, but these errors were encountered: