Skip to content

Latest commit

 

History

History
325 lines (254 loc) · 13.1 KB

README.md

File metadata and controls

325 lines (254 loc) · 13.1 KB

Summary

Simple node.js program to simulate a set of charging stations based on the OCPP-J 1.6 protocol.

Prerequisites

Windows

choco install -y nodejs-lts

MacOSX

brew install node@14

GNU/Linux:

  • NodeSource Node.js Binary Distributions for version 14.X

Configuration syntax

All configuration files are in the JSON standard format.

The charging stations simulator's main configuration parameters must be within the src/assets/config.json file. A configuration template file is available at src/assets/config-template.json.

All charging station templates are in the directory src/assets/station-templates.

A list of RFID tags must be defined for the automatic transaction generator with the default location and name src/assets/authorization-tags.json. A template file is available at src/assets/authorization-tags-template.json.

The charging stations simulator have an automatic configuration files reload feature at change for:

  • main configuration;
  • charging station templates;
  • authorization RFID tags.

But the modifications to test have to be done to the files in the build result directory dist/assets. Once the modifications are finished, they have to be reported or copied to the matching files in the build source directory src/assets to ensure they will be taken into account at next build.

Main configuration

src/assets/config.json:

Key Value(s) Default Value Value type Description
supervisionURLs [] string[] array of connection URIs to OCPP-J servers
distributeStationsToTenantsEqually true/false true boolean distribute charging stations uniformly to the OCPP-J servers
workerProcess workerSet/staticPool/dynamicPool workerSet string worker threads process type
workerStartDelay 500 integer milliseconds to wait at charging station worker threads startup
workerPoolMinSize 4 integer worker threads pool minimum number of threads
workerPoolMaxSize 16 integer worker threads pool maximum number of threads
workerPoolStrategy ROUND_ROBIN/LESS_RECENTLY_USED/... poolifier default: ROUND_ROBBIN string worker threads pool poolifier worker choice strategy
chargingStationsPerWorker 1 integer number of charging stations per worker threads for the workerSet process type
logStatisticsInterval 60 integer seconds between charging stations statistics output in the logs
logConsole true/false false boolean output logs on the console
logFormat simple string winston log format
logRotate true/false true boolean enable daily log files rotation
logMaxFiles 7 integer maximum number of log files to keep
logLevel emerg/alert/crit/error/warning/notice/info/debug info string winston logging level
logFile combined.log string log file relative path
logErrorFile error.log string error log file relative path
performanceStorage { "enabled": false, "type": "jsonfile", "file:///performanceRecords.json" } { enabled: string; type: string; URI: string; } where type can be 'jsonfile' or 'mongodb' performance storage configuration section
stationTemplateURLs {}[] { file: string; numberOfStations: number; }[] array of charging station templates URIs configuration section (template file name and number of stations)

Worker process model:

  • workerSet: Worker set executing each a static number (chargingStationsPerWorker) of simulated charging stations from the total

  • staticPool: Statically sized worker pool executing a static total number of simulated charging stations

  • dynamicPool: Dynamically sized worker pool executing a static total number of simulated charging stations

Charging station template

Key Value(s) Default Value Value type Description
supervisionURL '' string connection URI to OCPP-J server
supervisionUser '' string basic HTTP authentication user to OCPP-J server
supervisionPassword '' string basic HTTP authentication password to OCPP-J server
ocppVersion 1.6 1.6 string OCPP version
ocppProtocol json json string OCPP protocol
authorizationFile '' string RFID tags list file relative to src/assets path
baseName '' string base name to build charging stations name
nameSuffix '' string name suffix to build charging stations name
fixedName true/false false boolean use the baseName as the charging stations unique name
chargePointModel '' string charging stations model
chargePointVendor '' string charging stations vendor
chargeBoxSerialNumberPrefix '' string charging stations serial number prefix
firmwareVersion '' string charging stations firmware version
power float|float[] charging stations maximum power value(s)
powerSharedByConnectors true/false false boolean charging stations power shared by its connectors
powerUnit W/kW W string charging stations power unit
currentOutType AC/DC AC string charging stations current out type
voltageOut AC:230/DC:400 integer charging stations voltage out
numberOfPhases 0/1/3 AC:3/DC:0 integer charging stations number of phase(s)
numberOfConnectors integer|integer[] charging stations number of connector(s)
useConnectorId0 true/false true boolean use connector id 0 definition from the template
randomConnectors true/false false boolean randomize runtime connector id affectation from the connector id definition in template
resetTime 60 integer seconds to wait before the charging stations come back at reset
autoRegister true/false false boolean set the charging station as registered at boot notification for testing purpose
autoReconnectMaxRetries -1 (unlimited) integer connection retries to the OCPP-J server
reconnectExponentialDelay true/false false boolean connection delay retry to the OCPP-J server
registrationMaxRetries -1 (unlimited) integer charging stations boot notification retries
enableStatistics true/false true boolean enable charging stations statistics
mayAuthorizeAtRemoteStart true/false true boolean always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
beginEndMeterValues true/false false boolean enable Transaction.{Begin,End} MeterValues
outOfOrderEndMeterValues true/false false boolean send Transaction.End MeterValues out of order
meteringPerTransaction true/false true boolean enable metering history on a per transaction basis
transactionDataMeterValues true/false false boolean enable transaction data MeterValues at stop transaction
mainVoltageMeterValues true/false true boolean include charging station main voltage MeterValues on three phased charging stations
phaseLineToLineVoltageMeterValues true/false true boolean include charging station line to line voltage MeterValues on three phased charging stations
Configuration ChargingStationConfiguration charging stations OCPP parameters configuration section
AutomaticTransactionGenerator AutomaticTransactionGenerator charging stations ATG configuration section
Connectors Connectors charging stations connectors configuration section

Configuration section

  "Configuration": {
    "configurationKey": [
       ...
       {
        "key": "StandardKey",
        "readonly": false,
        "value": "StandardValue",
        "visible": true,
        "reboot": false
      },
      ...
      {
        "key": "VendorKey",
        "readonly": false,
        "value": "VendorValue",
        "visible": false,
        "reboot": true
      },
      ...
    ]
  }

AutomaticTransactionGenerator section

  "AutomaticTransactionGenerator": {
    "enable": false,
    "minDuration": 60,
    "maxDuration": 80,
    "minDelayBetweenTwoTransactions": 15,
    "maxDelayBetweenTwoTransactions": 30,
    "probabilityOfStart": 1,
    "stopAfterHours": 0.3,
    "stopOnConnectionFailure": true,
    "requireAuthorize": true
  }

Connectors section

  "Connectors": {
    "0": {},
    "1": {
      "bootStatus": "Available",
      "MeterValues": [
        ...
        {
          "unit": "W",
          "measurand": "Power.Active.Import",
          "phase": "L1-N",
          "value": "5000",
          "fluctuationPercent": "10"
        },
        ...
        {
          "unit": "A",
          "measurand": "Current.Import"
        },
        ...
        {
          "unit": "Wh"
        },
        ...
      ]
    }
  },

Start

To start the program, run: npm start.

Docker

In the docker folder:

make

Or with the optional git submodules:

make SUBMODULES_INIT=true

OCPP-J commands supported

Version 1.6

Core Profile

  • ✅ Authorize
  • ✅ BootNotification
  • ✅ ChangeAvailability
  • ✅ ChangeConfiguration
  • ✅ ClearCache
  • ❌ DataTransfer
  • ✅ GetConfiguration
  • ✅ Heartbeat
  • ✅ MeterValues
  • ✅ RemoteStartTransaction
  • ✅ RemoteStopTransaction
  • ✅ Reset
  • ✅ StartTransaction
  • ✅ StatusNotification
  • ✅ StopTransaction
  • ✅ UnlockConnector

Firmware Management Profile

  • ✅ GetDiagnostics
  • ❌ DiagnosticsStatusNotification
  • ❌ FirmwareStatusNotification
  • ❌ UpdateFirmware

Local Auth List Management Profile

  • ❌ GetLocalListVersion
  • ❌ SendLocalList

Reservation Profile

  • ❌ CancelReservation
  • ❌ ReserveNow

Smart Charging Profile

  • ✅ ClearChargingProfile
  • ✅ GetCompositeSchedule
  • ✅ SetChargingProfile

Remote Trigger Profile

  • ✅ TriggerMessage

OCPP-J standard parameters supported

All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.

Version 1.6

Core Profile

  • ✅ AuthorizeRemoteTxRequests (type: boolean) (units: -)
  • ❌ ClockAlignedDataInterval (type: integer) (units: seconds)
  • ✅ ConnectionTimeOut (type: integer) (units: seconds)
  • ❌ GetConfigurationMaxKeys (type: integer) (units: -)
  • ✅ HeartbeatInterval (type: integer) (units: seconds)
  • ❌ LocalAuthorizeOffline (type: boolean) (units: -)
  • ❌ LocalPreAuthorize (type: boolean) (units: -)
  • ❌ MeterValuesAlignedData (type: CSL) (units: -)
  • ✅ MeterValuesSampledData (type: CSL) (units: -)
  • ✅ MeterValueSampleInterval (type: integer) (units: seconds)
  • ✅ NumberOfConnectors (type: integer) (units: -)
  • ❌ ResetRetries (type: integer) (units: times)
  • ✅ ConnectorPhaseRotation (type: CSL) (units: -)
  • ❌ StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
  • ❌ StopTransactionOnInvalidId (type: boolean) (units: -)
  • ❌ StopTxnAlignedData (type: CSL) (units: -)
  • ❌ StopTxnSampledData (type: CSL) (units: -)
  • ✅ SupportedFeatureProfiles (type: CSL) (units: -)
  • ❌ TransactionMessageAttempts (type: integer) (units: times)
  • ❌ TransactionMessageRetryInterval (type: integer) (units: seconds)
  • ❌ UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
  • ✅ WebSocketPingInterval (type: integer) (units: seconds)

Firmware Management Profile

  • none

Local Auth List Management Profile

  • ✅ LocalAuthListEnabled (type: boolean) (units: -)
  • ❌ LocalAuthListMaxLength (type: integer) (units: -)
  • ❌ SendLocalListMaxLength (type: integer) (units: -)

Reservation Profile

  • none

Smart Charging Profile

  • ❌ ChargeProfileMaxStackLevel (type: integer) (units: -)
  • ❌ ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
  • ❌ ChargingScheduleMaxPeriods (type: integer) (units: -)
  • ❌ MaxChargingProfilesInstalled (type: integer) (units: -)

Remote Trigger Profile

  • none

License

This file and all other files in this repository are licensed under the Apache Software License, v.2 and copyrighted under the copyright in NOTICE file, except as noted otherwise in the LICENSE file or the code source file header.

Please note that Docker images can contain other software which may be licensed under different licenses. This LICENSE and NOTICE files are also included in the Docker image. For any usage of built Docker images please make sure to check the licenses of the artifacts contained in the images.