Notifications
You must be signed in to change notification settings - Fork 1
/
modbus_nilanec.yaml
614 lines (581 loc) · 17.2 KB
/
modbus_nilanec.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
modbus:
- name: NilanEC
type: tcp
host: 192.168.9.140
port: 502
retry_on_empty: true
message_wait_milliseconds: 30
retries: 3
delay: 2
#climates:
# - name: "NilanEC Set Temperature"
# unique_id: NilanEC.TempSet
# address: 1201
# input_type: input
# max_temp: 30
# min_temp: 15
# precision: 0
# scale: 0.01
# count: 1
# target_temp_register: 1004
# temp_step: 1
# temperature_unit: °C
sensors:
# Display
- name: "NilanEC LED 1"
slave: 30
scan_interval: 60
unique_id: NilanEC.Display_LED1
state_class: measurement
input_type: input
address: 2000
- name: "NilanEC LED 2"
slave: 30
unique_id: NilanEC.Display_LED2
state_class: measurement
input_type: input
address: 2001
# compressor-heater
- name: "NilanEC Compressor"
address: 109
unique_id: NilanEC.Output.Compressor
input_type: holding
state_class: measurement
device_class: power
scan_interval: 60
slave: 30
- name: "NilanEC WaterHeat"
address: 116
unique_id: NilanEC.Output.WaterHeat
input_type: holding
state_class: measurement
device_class: power
scan_interval: 60
slave: 30
- name: "NilanEC.Output.Defrosting"
address: 125
unique_id: NilanEC.Output.Defrosting
input_type: holding
state_class: measurement
device_class: power
scan_interval: 60
slave: 30
# temperatures
- name: "NilanEC Temperature Controller"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T0_Controller
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 200
count: 1
- name: "NilanEC Temperature Intake"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T1_Intake
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 201
count: 1
#- name: NilanEC.Input.T2_Inlet
# slave: 30
# unique_id: NilanEC.Input.T2_Inlet
# device_class: temperature
# unit_of_measurement: °C
# state_class: measurement
# input_type: input
# data_type: int16
# precision: 2
# scale: 0.01
# address: 202
# count: 1
#- name: NilanEC.Input.T3_Exhaust
# slave: 30
# unique_id: NilanEC.Input.T3_Exhaust
# device_class: temperature
# unit_of_measurement: °C
# state_class: measurement
# input_type: input
# data_type: int16
# precision: 2
# scale: 0.01
# address: 203
# count: 1
#- name: NilanEC.Input.T4_Outlet
# slave: 30
# unique_id: NilanEC.Input.T4_Outlet
# device_class: temperature
# unit_of_measurement: °C
# state_class: measurement
# input_type: input
# data_type: int16
# precision: 2
# scale: 0.01
# address: 204
# count: 1
- name: "NilanEC Temperature Condenser"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T5_Cond
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 205
count: 1
- name: "NilanEC Temperature Evaporator"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T6_Evap
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 206
count: 1
- name: "NilanEC Temperature Inlet"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T7_Inlet
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 207
count: 1
- name: "NilanEC Temperature Outdoor"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T8_Outdoor
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 208
count: 1
#- name: NilanEC.Input.T9_Heater
# slave: 30
# unique_id: NilanEC.Input.T9_Heater
# device_class: temperature
# unit_of_measurement: °C
# state_class: measurement
# input_type: input
# data_type: int16
# precision: 2
# scale: 0.01
# address: 209
# count: 1
- name: "NilanEC Temperature External"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T10_Extern
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 210
count: 1
- name: "NilanEC Temperature Water Top"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T11_Top
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 211
count: 1
- name: "NilanEC Temperature Water Bottom"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T12_Bottom
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 212
count: 1
#- name: NilanEC.Input.T13_Return
# slave: 30
# unique_id: NilanEC.Input.T13_Return
# device_class: temperature
# unit_of_measurement: °C
# state_class: measurement
# input_type: input
# data_type: int16
# precision: 2
# scale: 0.01
# address: 213
# count: 1
#- name: NilanEC.Input.T14_Supply
# slave: 30
# unique_id: NilanEC.Input.T14_Supply
# device_class: temperature
# unit_of_measurement: °C
# state_class: measurement
# input_type: input
# data_type: int16
# precision: 2
# scale: 0.01
# address: 214
# count: 1
- name: "NilanEC Temperature Room"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.T15_Room
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 215
count: 1
# temperature deep settings
- name: "NilanEC Temperature Summer Min"
slave: 30
scan_interval: 900
unique_id: NilanEC.AirTemp.TempMinSum
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 1201
count: 1
- name: "NilanEC Temperature Winter Min"
slave: 30
scan_interval: 900
unique_id: NilanEC.AirTemp.TempMinWin
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 1202
count: 1
- name: "NilanEC Temperature Summer Max"
slave: 30
scan_interval: 900
unique_id: NilanEC.AirTemp.TempMaxSum
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 1203
count: 1
- name: "NilanEC Temperature Winter Max"
slave: 30
scan_interval: 900
unique_id: NilanEC.AirTemp.TempMaxWin
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 1204
count: 1
- name: "NilanEC Temperature Summer/Winter Limit"
slave: 30
scan_interval: 900
unique_id: NilanEC.AirTemp.TempSummer
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 1205
count: 1
- name: "NilanEC Water Top temperature setpoint (Electric)"
slave: 30
scan_interval: 900
unique_id: NilanEC.Hotwater.TempSet_T11
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 1700
count: 1
- name: "NilanEC Water Bottom temperature setpoint (Compressor)"
slave: 30
scan_interval: 900
unique_id: NilanEC.Hotwater.TempSet_T12
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: holding
data_type: int16
precision: 1
scale: 0.01
address: 1701
count: 1
# humidity
- name: "NilanEC Relative Humidity"
slave: 30
scan_interval: 60
unique_id: NilanEC.Input.RH
device_class: humidity
unit_of_measurement: "%"
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 221
count: 1
# control
- name: "NilanEC Run State Actual"
slave: 30
scan_interval: 60
unique_id: NilanEC.Control.RunAct
state_class: measurement
input_type: input
data_type: int16
address: 1000
count: 1
- name: "NilanEC Mode Actual"
slave: 30
scan_interval: 60
unique_id: NilanEC.Control.ModeAct
state_class: measurement
input_type: input
data_type: int16
address: 1001
count: 1
- name: "NilanEC State"
slave: 30
scan_interval: 60
unique_id: NilanEC.Control.State
state_class: measurement
input_type: input
data_type: int16
address: 1002
count: 1
- name: "NilanEC Duration In State"
slave: 30
scan_interval: 60
unique_id: NilanEC.Control.SecInState
device_class: duration
unit_of_measurement: s
state_class: measurement
input_type: input
data_type: int16
address: 1003
count: 1
- name: "NilanEC Fan Speed Set"
slave: 30
scan_interval: 60
unique_id: NilanEC.Control.VentSet
state_class: measurement
input_type: holding
data_type: int16
address: 1003
count: 1
# alarms
- name: "NilanEC Alarm Status"
slave: 30
scan_interval: 300
unique_id: NilanEC.Alarm.Status
state_class: measurement
input_type: input
data_type: int16
address: 400
count: 1
- name: "NilanEC Alarm 1 ID"
slave: 30
scan_interval: 300
unique_id: NilanEC.Alarm.List_1_ID
state_class: measurement
input_type: input
data_type: int16
address: 401
count: 1
- name: "NilanEC Alarm 2 ID"
slave: 30
scan_interval: 300
unique_id: NilanEC.Alarm.List_2_ID
state_class: measurement
input_type: input
data_type: int16
address: 404
count: 1
- name: "NilanEC Alarm 3 ID"
slave: 30
scan_interval: 300
unique_id: NilanEC.Alarm.List_3_ID
state_class: measurement
input_type: input
data_type: int16
address: 407
count: 1
# airtemp
- name: "NilanEC IsSummer"
slave: 30
scan_interval: 300
unique_id: NilanEC.AirTemp.IsSummer
state_class: measurement
input_type: input
address: 1200
- name: "NilanEC Temperature Set"
slave: 30
scan_interval: 60
unique_id: NilanEC.AirTemp.TempInletSet
device_class: temperature
unit_of_measurement: °C
state_class: measurement
input_type: input
data_type: int16
precision: 0
offset: 1
scale: 0.01
address: 1201
count: 1
- name: "NilanEC Efficiency %"
slave: 30
scan_interval: 60
unique_id: NilanEC.AirTemp.EffPct
device_class: power_factor
unit_of_measurement: "%"
state_class: measurement
input_type: input
data_type: int16
precision: 1
scale: 0.01
address: 1204
count: 1
# Output
- name: "NilanEC Fan Exhaust Speed"
slave: 30
scan_interval: 60
unique_id: NilanEC.Output.ExhaustSpeed
device_class: power_factor
unit_of_measurement: "%"
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 200
count: 1
- name: "NilanEC Fan Inlet Speed"
slave: 30
scan_interval: 60
unique_id: NilanEC.Output.InletSpeed
device_class: power_factor
unit_of_measurement: "%"
state_class: measurement
input_type: holding
data_type: int16
precision: 0
scale: 0.01
address: 201
count: 1
# create cleartext sensors and binary sensor
template:
sensor:
- name: "NilanEC Mode"
unique_id: NilanEC.Control.ModeAct.clear
state: >
{% set CMA = states('sensor.nilanec_control_modeact') | int %}
{% if CMA == 0 %}
Off
{% elif CMA == 1 %}
Heat
{% elif CMA == 2 %}
Cool
{% elif CMA == 3 %}
Auto
{% elif CMA == 4 %}
Service
{% else %}
Unknown State!
{% endif %}
- name: "NilanEC State"
unique_id: NilanEC.Control.State.clear
state: >
{% set CS = states('sensor.nilanec_control_state') | int %}
{% if CS == 0 %}
Off
{% elif CS == 1 %}
Shift
{% elif CS == 2 %}
Stop
{% elif CS == 3 %}
Start
{% elif CS == 4 %}
Standby
{% elif CS == 5 %}
Ventilation stop
{% elif CS == 6 %}
Ventilation
{% elif CS == 7 %}
Heating
{% elif CS == 8 %}
Cooling
{% elif CS == 9 %}
Hot water
{% elif CS == 10 %}
Legionella
{% elif CS == 11 %}
Cooling + hot water
{% elif CS == 12 %}
Central heating
{% elif CS == 13 %}
Defrost
{% elif CS == 14 %}
Frost secure
{% elif CS == 15 %}
Service
{% elif CS == 16 %}
Alarm
{% elif CS == 17 %}
Heating + hot water
{% else %}
Unknown State!
{% endif %}