-
Notifications
You must be signed in to change notification settings - Fork 6
/
help_vna.html
144 lines (137 loc) · 6.87 KB
/
help_vna.html
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
<!DOCTYPE html>
<html>
<head>
<meta http-equiv="content-type" content="text/html; charset=utf-8">
<meta name="description" content="Documentation for Quisk VNA"><meta name="author" content="James C. Ahlstrom"><meta name="keywords" content="quisk, vna, vector network analyzer, ham radio">
<title>QUISK Help File</title>
</head><body>
<h3>
Quisk VNA Help (December 2016)
</h3>
<p>This is the Help file for Quisk VNA, a program that turns the
Quisk2010 and HiQSDR transceiver and the Hermes-Lite transceiver into a Vector Network Analyzer
(VNA). This Help appears when you press the Help button. Quisk is written by Jim
Ahlstrom, N2ADR,
www.james.ahlstrom.name. Mail to jahlstr at gmail.com. To run the
Quisk VNA program, use "python quisk_vna.py" or set up a
shortcut. This program only works with hardware that is based
on UDP. It does not work with SoftRock hardware.
</p>
<p>For HiQSDR you need to update your firmware to Version 1.3 or later.
For Hermes-Lite update to 32 or later. The
new firmware locks the phase of the RF output to the phase of the RF
detector. There is a time delay in the path, but this is removed
by the calibration procedure. The calibration graphs will show a linear phase change with frequency due to this delay.
</p>
<p>There are two ways to use your hardware. You could connect the
RF output through attenuators, through a device under test and then
back to the RF input. This is called transmission mode. It is
used to plot the response of filters and to measure the electrical
length of cables. Or you could connect the RF input and output through
attenuators to
a resistive return loss bridge. This is called reflection mode. It is
used to measure SWR and impedance. You must choose a mode and
calibrate for that mode and hardware before you take any data.
The calibration is saved and will be restored the next time the
program starts. This is convenient when making repeated measurements,
but you should calibrate frequently for best accuracy. Hermes-Lite requires a power
on/off and a calibration before taking data, but the calibration is good until it is powered down.
</p>
<p>
The hardware generates RF output only when one of the "Calibrate"
buttons or the "Run" button is turned on.
The calibration routines save data every 15 kHz from zero
to sixty megahertz (thirty for Hermes-Lite). You can change the measurement frequency span
at any time without recalibration. Although you can set a
frequency span up to sixty (thirty) megahertz, my original hardware has a low
pass filter cutoff of 35 megahertz, so the upper frequency range is
smaller and will appear noisy.
Since the transmit and receive frequencies are equal, the data is at
DC, and is averaged and effectively low pass filtered. This
provides immunity from interference when measuring an antenna.
<h3 id="g0.0.1">Input Protection </h3>
Do not connect the RF output to the RF input without inserting
attenuators. The output will overload the input and result in
clipping in the ADC and possible damage. If your device under
test is an amplifier be especially careful to add additional
attenuation to avoid damage. Add enough attenuation to avoid
clipping, but not so much that you lose dynamic range. The
calibration screens show the ADC level. These attenuators also
help to stabilize the input and output impedance and increase
accuracy. I use the HAT series of attenuators from Mini-Circuits.
<h3 id="g0.0.2">Transmission Mode
</h3>
You must perform a calibration before you can take data. First
set the mode to "Transmission" and leave it there. Connect attenuators
and a cable between the RF input and output. Press the "Calibrate.." button.
With the cable connected press "Short". The "Short" calibration is
required for transmission mode. For the optional "Open" calibration, disconnect
the cable and press "Open". Then press "Calibrate" to save the calibration.
Connect the cable and press "Run" and
you should see a flat line at zero dB level and zero phase. Now
insert your test device in series. The test device could be a
filter, an amplifier (be careful) or an additional length of
cable. Press "Run" to take data.
<h3 id="g0.0.3">Reflection Mode
</h3>
<p>
This mode is used with a resistive return loss bridge.
Connect the RF
output to the generator terminal, and the RF input to the detector
terminal. Use attenuators on both. You must
perform a calibration before you can take data.
First set the
mode to "Reflection" and leave it there. Press the "Calibrate.." button.
Connect an open circuit (or nothing) to
the impedance
terminal of the bridge, and then press "Open". Connect a
short circuit to the bridge, and then press "Short". Connect
a 50 ohm termination to the bridge and then press "Load".
Then press "Calibrate" to save the calibration.
If you do not have a set of Open/Short/Load standards, you can just
use "Open" alone, but it is highly
recommended to use Open, Short and Load.
</p>
<p>
Now connect a 50 ohm termination to the bridge, and
press "Run". The graph will show the magnitude and phase of the
reflection coefficient, and the return loss is the drop in magnitude
below zero dB. Ideally your bridge will have a directivity of 30
dB or more. The phase may be noisy if the magnitude is very
small. Now connect an
unknown impedance to the bridge; for example, an antenna. The
graph will plot the return loss, reflection coefficient and SWR.
The status line will display the frequency, the reflection coefficient and SWR, the impedance, the equivalent
capacitance or inductance for that impedance, and the values for the parallel equivalent circuit.
</p>
<p>
You can attach any impedance, such as an unknown capacitor or inductor,
and read the value directly. The value may seem to vary with
frequency due to stray inductance, variation of permeability with
frequency, and bridge imperfections; so choose a reference frequency
wisely. Remember that the bridge measures the impedance relative
to fifty ohms, so accuracy suffers if the impedance is outside the
range of 5 to 500 ohms or so.
</p>
<h3 id="g0.0.4">Fun</h3>
<p>
In transmission mode, add an extra length of cable and see the phase
change. When the phase change is ninety degrees, that is a
quarter wave. The effect of velocity factor is included, and can
be measured. Use a bare wire (with attenuators) as the test
fixture, and then add a ferrite bead to the wire to measure its
properties. Insert a filter to see its response.
</p>
<p>
In reflection mode, measure your antenna from zero to sixty (thirty)
megahertz. If it is a dipole, you will see the drop in SWR at its fundamental and
third harmonic. Add a cable to the bridge to see its impedance at
a quarter and half wave length. Measure the length of your
transmission line by replacing your antenna with a 100 ohm
resister. The bridge will read 100 ohms at multiples of a half
wavelength. If you short out your antenna at the far end of your
transmission line, the bridge will read zero at half wavelengths, and
infinity at quarter wavelengths.
</p>
</body>
</html>