Notifications
You must be signed in to change notification settings - Fork 5
/
rego1000.yaml
196 lines (183 loc) · 4.43 KB
/
rego1000.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
esphome:
name: heatpump-logger
esp32:
board: nodemcu-32s
framework:
type: arduino
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
ap:
ssid: "esp-rego1000"
password: !secret fallback_password
logger:
level: INFO
baud_rate: 0
api:
password: !secret hass_api_password
# The OTA configuration was changed in esphome 2024.06.
# For earlier releases the '- platform: esphome' should not be included
ota:
- platform: esphome
password: !secret ota_password
external_components:
- source: components
web_server:
canbus:
- platform: esp32_can
id: can0
can_id: 0
tx_pin: GPIO23
rx_pin: GPIO22
bit_rate: 125kbps
climate:
- platform: rego1000
name: House
rego_setpoint_variable: $ROOM_SETPOINT_BASE_TEMP
sensor_id: indoor_temp
sensor:
- platform: homeassistant
entity_id: sensor.indoor_temperature
id: indoor_temp
accuracy_decimals: 1
- platform: rego1000
name: Heat Carrier 1
rego_variable: $GT1_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Outdoor
rego_variable: $GT2_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Warm water
rego_variable: $GT3_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Hot gas
rego_variable: $GT6_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Heat fluid out
rego_variable: $GT8_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Heat fluid in
rego_variable: $GT9_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Cold fluid in
rego_variable: $GT10_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Cold fluid out
rego_variable: $GT11_TEMP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Heating start
rego_variable: $HEATING_START
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Heating stop
rego_variable: $HEATING_STOP
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
- platform: rego1000
name: Heating setpoint
rego_variable: $HEATING_SETPOINT
value_factor: .1
unit_of_measurement: °C
state_class: measurement
accuracy_decimals: 1
# - platform: rego1000
# name: Energy output
# rego_variable: $STATS_ENERGY_OUTPUT
# value_factor: .01
# unit_of_measurement: kWh
# state_class: "total_increasing"
# device_class: "energy"
# accuracy_decimals: 2
binary_sensor:
- platform: rego1000
name: "Heat carrier pump"
rego_listen_can_id: 0x00028${REGO_CAN_SUFFIX}
- platform: rego1000
name: "Heat fluid pump"
rego_listen_can_id: 0x0002c${REGO_CAN_SUFFIX}
- platform: rego1000
name: "Three-way valve"
rego_listen_can_id: 0x00038${REGO_CAN_SUFFIX}
- platform: rego1000
name: "Additional heat"
rego_listen_can_id: 0x0003c${REGO_CAN_SUFFIX}
- platform: rego1000
name: "Compressor"
rego_listen_can_id: 0x00048${REGO_CAN_SUFFIX}
- platform: rego1000
name: "Cold fluid pump"
rego_listen_can_id: 0x00054${REGO_CAN_SUFFIX}
number:
- platform: rego1000
name: Hysterisis min
rego_variable: $HEATING_1A_DIFF_MIN
unit_of_measurement: °C
min_value: 2
max_value: 30
step: .1
value_factor: .1
- platform: rego1000
name: Hysterisis max
rego_variable: $HEATING_1A_DIFF_MAX
unit_of_measurement: °C
min_value: 2
max_value: 30
step: .1
value_factor: .1
- platform: rego1000
name: Hysterisis time factor
rego_variable: $HEATING_1A_DIFF_CONST
min_value: 10
max_value: 30
step: 1
value_factor: .1
- platform: rego1000
name: Room dial range
rego_variable: $ROOM_DIAL_RANGE
min_value: 0
max_value: 6
step: 1
switch:
- platform: rego1000
name: "DHW Economy"
rego_variable: $DHW_STATE_ECONOMY
- platform: rego1000
name: "Admin access"
rego_variable: $ACCESS_LEVEL