From 0463d4e7f63461febf779500cac794a70469fc11 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Tue, 12 Nov 2024 21:14:35 +0000 Subject: [PATCH 01/11] hydronic systems new types --- .../resources/HVAC/entity_types/ABSTRACT.yaml | 25 +++++++++++++++ .../resources/HVAC/entity_types/CDWS.yaml | 9 ++++++ .../yaml/resources/HVAC/entity_types/CH.yaml | 31 +++++++++++++++++++ .../resources/HVAC/entity_types/CHWS.yaml | 21 +++++++++++++ .../yaml/resources/HVAC/entity_types/HX.yaml | 9 ++++++ .../resources/fields/telemetry_fields.yaml | 6 ++++ 6 files changed, 101 insertions(+) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 32a9356bf..74f10f834 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -770,6 +770,7 @@ SS: - lost_power_alarm - communication_status - efficiency_percentage_sensor + - load_percentage_sensor DSPC: guid: "3f288511-32ca-47ae-a4e0-391620026420" @@ -8242,6 +8243,30 @@ WSEBYPVPM: implements: - MONITORING +MCBYPVPM: + description: "Mechanical cooling bypass valve monitoring." + is_abstract: true + opt_uses: + - economizer_mode + - sync_economizer_mechanical_cooling_mode + - mechanical_cooling_bypass_valve_percentage_sensor + uses: + - mechanical_cooling_bypass_valve_percentage_command + implements: + - MONITORING + +BYPVFRC: + description: "Mechanical cooling bypass valve monitoring." + is_abstract: true + opt_uses: + - bypass_valve_percentage_sensor + uses: + - bypass_valve_percentage_command + - flowrate_sensor + - flowrate_setpoint + implements: + - CONTROL + FSWISOVM: guid: "58f0a5fb-fc3e-4384-91b1-ba7db225ec6c" description: "Filtration supply isolation valve monitoring." diff --git a/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml index 8e64fba25..03ff62150 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml @@ -110,6 +110,15 @@ CDWS_SWTC_WDPM_SWPSS: - WDPM - SWPSS +CDWS_SWTC_WDPM_CLPM: + description: "Condenser water system with differential pressure monitoring and cooling thermal monitoring." + is_canonical: true + implements: + - CDWS + - SWTC + - WDPM + - CLPM + CDWS_CLPM_SWTC_WDPM_WFRC: guid: "571a238d-3540-4f4d-ba11-5b61e43e9b3b" description: "Condensing water system with supply temperature and flowrate control as well as thermal power and differential pressure monitoring." diff --git a/ontology/yaml/resources/HVAC/entity_types/CH.yaml b/ontology/yaml/resources/HVAC/entity_types/CH.yaml index 3168759f4..dab3f7896 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CH.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CH.yaml @@ -263,6 +263,21 @@ CH_SS_SCHWTC_CHPM_REFSM_DXSWC_CHWRWISOVM_IGM: - CHWRWISOVM - IGM +CH_SS_SCHWTC_CHWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: + description: "Water-cooled chiller with pressure and refrigerant temperature and pressure monitoring." + is_canonical: true + implements: + - CH + - SS + - SCHWTC + - CHWDT + - WDPM + - REFSM + - REFPM + - CHDXSC + - CHWRWISOVM + - IGM + CH_SS_SCHWTC_CHWRWISOVPM_CWRISOVPM_CHPM_CWDT_REFSM_CHWDPM: guid: "bca8842a-ad65-4ddc-925f-e97129f5c2d9" description: "Water-cooled chiller." @@ -402,6 +417,22 @@ CH_SS_CHWRWISOVPM_SCHWTC_CHWDPM_CDWISOVPM_CWDT_REFPM_REFSM_IGM_DXSWC: - IGM - DXSWC +CH_SS_CHWRWISOVPM_SCHWTC_CHWDPM_CDWISOVPM_CWDT_REFPM_REFSM_IGM_CHDXSC: + description: "Complex water-cooled chiller." + is_canonical: true + implements: + - CH + - SS + - CHWRWISOVPM + - SCHWTC + - CHWDPM + - CDWISOVPM + - CWDT + - REFPM + - REFSM + - IGM + - CHDXSC + CH_SS_SCHWTC_CHWSWISOVM_CHWDPM_CWDT_REFSM_REFPM_IGM_DXSWC: guid: "e3e3ff1b-4d52-4234-aac0-1692fac0ee77" description: "Complex water-cooled chiller." diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index a0cbac35a..740ce35ed 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -156,6 +156,17 @@ CHWS_SWTC_WDPC_CLPM_WFRM_BYPVPM: - WFRM - BYPVPM +CHWS_SWTC_WDPC_BYPVFRC_MCBYPVPM_CLPM: + description: "Chilled water system with supply temperature and differential pressure control, bypass valve flowrate control, mechanical cooling bypass valve monitoring and thermal load monitoring." + is_canonical: true + implements: + - CHWS + - SWTC + - WDPC + - BYPVFRC + - MCBYPVPM + - CLPM + CHWS_SWTC_WDPC_CLPM_WFRC_BYPVPM: guid: "20c14eb4-763c-437d-9209-c35151e2251b" description: "Chilled water system with supply temperature, differential pressure, and flowrate control, and thermal load and bypass valve monitoring." @@ -232,6 +243,16 @@ CHWS_SWTC_WDPC2X_BYPVPM_WFRM_CLPM: - WFRM - CLPM +CHWS_SWTC_WDPC2X_BYPVFRC_CLPM: + description: "Chilled water system with dual differential pressure control, bypass valve flowrate control and cooling thermal monitoring." + is_canonical: true + implements: + - CHWS + - SWTC + - WDPC2X + - BYPVFRC + - CLPM + CHWS_RWTC_CHWVM: guid: "40d0d1a2-b819-4d1b-b01a-e7b900af0d8d" description: "Chilled water system with return temperature control and chilled water valve monitoring." diff --git a/ontology/yaml/resources/HVAC/entity_types/HX.yaml b/ontology/yaml/resources/HVAC/entity_types/HX.yaml index 866b2a560..578b4586f 100644 --- a/ontology/yaml/resources/HVAC/entity_types/HX.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/HX.yaml @@ -88,6 +88,15 @@ HX_CWDT_CHWDT_CWRISOVPM_CHWBYPVPM: - CWRISOVPM - CHWBYPVPM +HX_CWDT_CHWDT_CWRISOVPM: + description: 'Condenser/chilled water heat exchanger.' + is_canonical: true + implements: + - HX + - CWDT + - CHWDT + - CWRISOVPM + HX_CHWDT_CWRISOVPM_CHWRWISOVPM: guid: "6cb20fa2-2dcf-4d38-8212-d2951fe39b95" description: "Chilled and condenser water heat exchangers." diff --git a/ontology/yaml/resources/fields/telemetry_fields.yaml b/ontology/yaml/resources/fields/telemetry_fields.yaml index 39c63254d..55ec3f720 100644 --- a/ontology/yaml/resources/fields/telemetry_fields.yaml +++ b/ontology/yaml/resources/fields/telemetry_fields.yaml @@ -601,6 +601,12 @@ literals: - economizer_bypass_valve_percentage_sensor: fixed_min: 0 fixed_max: 100 +- mechanical_cooling_bypass_valve_percentage_command: + fixed_min: 0 + fixed_max: 100 +- mechanical_cooling_bypass_valve_percentage_sensor: + fixed_min: 0 + fixed_max: 100 - chilled_water_isolation_valve_status: - OPEN - CLOSED From 0f77487c8e4e26e96e89b6c009e00d0090487481 Mon Sep 17 00:00:00 2001 From: db-robot Date: Tue, 12 Nov 2024 21:15:31 +0000 Subject: [PATCH 02/11] Add GUIDs to new entity types --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 2 ++ ontology/yaml/resources/HVAC/entity_types/CDWS.yaml | 1 + ontology/yaml/resources/HVAC/entity_types/CH.yaml | 2 ++ ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 2 ++ ontology/yaml/resources/HVAC/entity_types/HX.yaml | 1 + 5 files changed, 8 insertions(+) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index 74f10f834..ff1e2e33e 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -8244,6 +8244,7 @@ WSEBYPVPM: - MONITORING MCBYPVPM: + guid: "ba06a118-c604-44e8-9ad7-aa5d7cad5e43" description: "Mechanical cooling bypass valve monitoring." is_abstract: true opt_uses: @@ -8256,6 +8257,7 @@ MCBYPVPM: - MONITORING BYPVFRC: + guid: "5c93b3ee-21bb-423c-8c84-9a22ffa1f931" description: "Mechanical cooling bypass valve monitoring." is_abstract: true opt_uses: diff --git a/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml index 03ff62150..46f0c7edc 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CDWS.yaml @@ -111,6 +111,7 @@ CDWS_SWTC_WDPM_SWPSS: - SWPSS CDWS_SWTC_WDPM_CLPM: + guid: "04503d61-feb3-43b1-9eea-57c2570610e3" description: "Condenser water system with differential pressure monitoring and cooling thermal monitoring." is_canonical: true implements: diff --git a/ontology/yaml/resources/HVAC/entity_types/CH.yaml b/ontology/yaml/resources/HVAC/entity_types/CH.yaml index dab3f7896..185ddfbbf 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CH.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CH.yaml @@ -264,6 +264,7 @@ CH_SS_SCHWTC_CHPM_REFSM_DXSWC_CHWRWISOVM_IGM: - IGM CH_SS_SCHWTC_CHWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: + guid: "74bda35f-625f-4472-947e-b9d10a4d2d3f" description: "Water-cooled chiller with pressure and refrigerant temperature and pressure monitoring." is_canonical: true implements: @@ -418,6 +419,7 @@ CH_SS_CHWRWISOVPM_SCHWTC_CHWDPM_CDWISOVPM_CWDT_REFPM_REFSM_IGM_DXSWC: - DXSWC CH_SS_CHWRWISOVPM_SCHWTC_CHWDPM_CDWISOVPM_CWDT_REFPM_REFSM_IGM_CHDXSC: + guid: "01d59f6f-3ed5-444d-8245-fe2d5ebb1f8c" description: "Complex water-cooled chiller." is_canonical: true implements: diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index 740ce35ed..c45738726 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -157,6 +157,7 @@ CHWS_SWTC_WDPC_CLPM_WFRM_BYPVPM: - BYPVPM CHWS_SWTC_WDPC_BYPVFRC_MCBYPVPM_CLPM: + guid: "553497fb-0c57-441c-bf74-3c7b0d713f9f" description: "Chilled water system with supply temperature and differential pressure control, bypass valve flowrate control, mechanical cooling bypass valve monitoring and thermal load monitoring." is_canonical: true implements: @@ -244,6 +245,7 @@ CHWS_SWTC_WDPC2X_BYPVPM_WFRM_CLPM: - CLPM CHWS_SWTC_WDPC2X_BYPVFRC_CLPM: + guid: "3a3fea1e-7f64-4ed9-9b18-bd1c62d53af2" description: "Chilled water system with dual differential pressure control, bypass valve flowrate control and cooling thermal monitoring." is_canonical: true implements: diff --git a/ontology/yaml/resources/HVAC/entity_types/HX.yaml b/ontology/yaml/resources/HVAC/entity_types/HX.yaml index 578b4586f..305429199 100644 --- a/ontology/yaml/resources/HVAC/entity_types/HX.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/HX.yaml @@ -89,6 +89,7 @@ HX_CWDT_CHWDT_CWRISOVPM_CHWBYPVPM: - CHWBYPVPM HX_CWDT_CHWDT_CWRISOVPM: + guid: "7d22f3c3-30be-46f9-bd13-1f88b374923c" description: 'Condenser/chilled water heat exchanger.' is_canonical: true implements: From c9a5a70bb21b58abfbe307d1c23b0aefcac3e410 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Tue, 12 Nov 2024 21:26:18 +0000 Subject: [PATCH 03/11] Description adjustment --- ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml | 2 +- ontology/yaml/resources/HVAC/entity_types/CH.yaml | 4 ++-- 2 files changed, 3 insertions(+), 3 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml index ff1e2e33e..5fcb3febb 100644 --- a/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml @@ -8258,7 +8258,7 @@ MCBYPVPM: BYPVFRC: guid: "5c93b3ee-21bb-423c-8c84-9a22ffa1f931" - description: "Mechanical cooling bypass valve monitoring." + description: "Bypass valve flowrate control." is_abstract: true opt_uses: - bypass_valve_percentage_sensor diff --git a/ontology/yaml/resources/HVAC/entity_types/CH.yaml b/ontology/yaml/resources/HVAC/entity_types/CH.yaml index 185ddfbbf..78808542b 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CH.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CH.yaml @@ -265,7 +265,7 @@ CH_SS_SCHWTC_CHPM_REFSM_DXSWC_CHWRWISOVM_IGM: CH_SS_SCHWTC_CHWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: guid: "74bda35f-625f-4472-947e-b9d10a4d2d3f" - description: "Water-cooled chiller with pressure and refrigerant temperature and pressure monitoring." + description: "Water-cooled chiller with refrigerant pressure and temperature monitoring." is_canonical: true implements: - CH @@ -420,7 +420,7 @@ CH_SS_CHWRWISOVPM_SCHWTC_CHWDPM_CDWISOVPM_CWDT_REFPM_REFSM_IGM_DXSWC: CH_SS_CHWRWISOVPM_SCHWTC_CHWDPM_CDWISOVPM_CWDT_REFPM_REFSM_IGM_CHDXSC: guid: "01d59f6f-3ed5-444d-8245-fe2d5ebb1f8c" - description: "Complex water-cooled chiller." + description: "Complex water-cooled chiller with refrigerant pressure and temperature monitoring." is_canonical: true implements: - CH From ee0cd767f15562174d632da00a3bad63c0440107 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Tue, 12 Nov 2024 21:28:31 +0000 Subject: [PATCH 04/11] Description adjustments --- ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index c45738726..197c8f1e7 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -158,7 +158,7 @@ CHWS_SWTC_WDPC_CLPM_WFRM_BYPVPM: CHWS_SWTC_WDPC_BYPVFRC_MCBYPVPM_CLPM: guid: "553497fb-0c57-441c-bf74-3c7b0d713f9f" - description: "Chilled water system with supply temperature and differential pressure control, bypass valve flowrate control, mechanical cooling bypass valve monitoring and thermal load monitoring." + description: "Chilled water system with supply temperature and differential pressure control, bypass valve flowrate control, mechanical cooling bypass valve monitoring and thermal monitoring." is_canonical: true implements: - CHWS From 8c29fe7291f83d76c630062b46df66004b7465a6 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Tue, 12 Nov 2024 23:27:58 +0000 Subject: [PATCH 05/11] Added CWDT to one CH type --- ontology/yaml/resources/HVAC/entity_types/CH.yaml | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/CH.yaml b/ontology/yaml/resources/HVAC/entity_types/CH.yaml index 78808542b..93b0d4395 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CH.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CH.yaml @@ -263,7 +263,8 @@ CH_SS_SCHWTC_CHPM_REFSM_DXSWC_CHWRWISOVM_IGM: - CHWRWISOVM - IGM -CH_SS_SCHWTC_CHWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: + +CH_SS_SCHWTC_CHWDT_CWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: guid: "74bda35f-625f-4472-947e-b9d10a4d2d3f" description: "Water-cooled chiller with refrigerant pressure and temperature monitoring." is_canonical: true @@ -272,6 +273,7 @@ CH_SS_SCHWTC_CHWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: - SS - SCHWTC - CHWDT + - CWDT - WDPM - REFSM - REFPM From 183d4badf7af91c6874edd0c3f7e5e6744bc1333 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Tue, 12 Nov 2024 23:33:25 +0000 Subject: [PATCH 06/11] removed redundant CHWDT from chiller type --- ontology/yaml/resources/HVAC/entity_types/CH.yaml | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/CH.yaml b/ontology/yaml/resources/HVAC/entity_types/CH.yaml index 93b0d4395..4ddbe7216 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CH.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CH.yaml @@ -264,7 +264,7 @@ CH_SS_SCHWTC_CHPM_REFSM_DXSWC_CHWRWISOVM_IGM: - IGM -CH_SS_SCHWTC_CHWDT_CWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: +CH_SS_SCHWTC_CWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: guid: "74bda35f-625f-4472-947e-b9d10a4d2d3f" description: "Water-cooled chiller with refrigerant pressure and temperature monitoring." is_canonical: true @@ -272,7 +272,6 @@ CH_SS_SCHWTC_CHWDT_CWDT_WDPM_REFSM_REFPM_CHDXSC_CHWRWISOVM_IGM: - CH - SS - SCHWTC - - CHWDT - CWDT - WDPM - REFSM From 3cd355bfe09011259ef9be2d3d0a88821751b196 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Tue, 12 Nov 2024 23:59:47 +0000 Subject: [PATCH 07/11] added new chws type --- ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 10 ++++++++++ 1 file changed, 10 insertions(+) diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index 197c8f1e7..575af4cb2 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -180,6 +180,16 @@ CHWS_SWTC_WDPC_CLPM_WFRC_BYPVPM: - WFRC - BYPVPM +CHWS_SWTC_WDPC_CLPM_BYPVFRC: + description: "Chilled water system with supply temperature, differential pressure, bypass valve flowrate control, and thermal load monitoring." + is_canonical: true + implements: + - CHWS + - SWTC + - WDPC + - BYPVFRC + - CLPM + CHWS_SWTC_WDPC_WFRM_PSWTC_PWVPM_MINFC_CLPM: guid: "7626e0e2-1e32-4101-b53b-5fa66af3cdc2" description: "Chilled water system with process water (typically used in lab applications)." From ec144da05eb00b0d3a7ffe7b13be3a7448777f06 Mon Sep 17 00:00:00 2001 From: db-robot Date: Wed, 13 Nov 2024 00:00:26 +0000 Subject: [PATCH 08/11] Add GUIDs to new entity types --- ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 1 + 1 file changed, 1 insertion(+) diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index 575af4cb2..3708fc0b2 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -181,6 +181,7 @@ CHWS_SWTC_WDPC_CLPM_WFRC_BYPVPM: - BYPVPM CHWS_SWTC_WDPC_CLPM_BYPVFRC: + guid: "2b835b66-3db9-499e-97f4-1e22540df676" description: "Chilled water system with supply temperature, differential pressure, bypass valve flowrate control, and thermal load monitoring." is_canonical: true implements: From dd87d0e088cfe57b3f2f13474c34a4c3e8959f4b Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Wed, 13 Nov 2024 00:08:03 +0000 Subject: [PATCH 09/11] rearranged name --- ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index 3708fc0b2..69f6e107f 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -180,7 +180,7 @@ CHWS_SWTC_WDPC_CLPM_WFRC_BYPVPM: - WFRC - BYPVPM -CHWS_SWTC_WDPC_CLPM_BYPVFRC: +CHWS_SWTC_WDPC_BYPVFRC_CLPM: guid: "2b835b66-3db9-499e-97f4-1e22540df676" description: "Chilled water system with supply temperature, differential pressure, bypass valve flowrate control, and thermal load monitoring." is_canonical: true From 33b8cec83667e4bf584f313ebdbe00766fc58b65 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Wed, 13 Nov 2024 00:09:03 +0000 Subject: [PATCH 10/11] fixed description --- ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index 69f6e107f..229c981d4 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -182,7 +182,7 @@ CHWS_SWTC_WDPC_CLPM_WFRC_BYPVPM: CHWS_SWTC_WDPC_BYPVFRC_CLPM: guid: "2b835b66-3db9-499e-97f4-1e22540df676" - description: "Chilled water system with supply temperature, differential pressure, bypass valve flowrate control, and thermal load monitoring." + description: "Chilled water system with supply temperature, differential pressure, bypass valve flowrate control, and cooling thermal monitoring." is_canonical: true implements: - CHWS From 480a767e6e990a9dd86b4f4221aebe2c2bd00490 Mon Sep 17 00:00:00 2001 From: evgeniya-engel Date: Wed, 13 Nov 2024 01:43:57 +0000 Subject: [PATCH 11/11] description adjustment --- ontology/yaml/resources/HVAC/entity_types/CHWS.yaml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml index 229c981d4..c8420d655 100644 --- a/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml +++ b/ontology/yaml/resources/HVAC/entity_types/CHWS.yaml @@ -158,7 +158,7 @@ CHWS_SWTC_WDPC_CLPM_WFRM_BYPVPM: CHWS_SWTC_WDPC_BYPVFRC_MCBYPVPM_CLPM: guid: "553497fb-0c57-441c-bf74-3c7b0d713f9f" - description: "Chilled water system with supply temperature and differential pressure control, bypass valve flowrate control, mechanical cooling bypass valve monitoring and thermal monitoring." + description: "Chilled water system with supply temperature and differential pressure control, bypass valve flowrate control, mechanical cooling bypass valve monitoring and cooling thermal monitoring." is_canonical: true implements: - CHWS