forked from athom-tech/esp32-configs
-
Notifications
You must be signed in to change notification settings - Fork 0
/
athom-energy-monitor-x2.yaml
385 lines (348 loc) · 9.66 KB
/
athom-energy-monitor-x2.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
substitutions:
name: "athom-em-2"
friendly_name: "Athom Energy Meter"
# Allows ESP device to be automatically lined to an 'Area' in Home Assistant. Typically used for areas such as 'Lounge Room', 'Kitchen' etc
room: ""
device_description: "athom bl0906 energy meter (2 channels)"
project_name: "Athom Technology.Athom Energy Meter(2 Channels)"
project_version: "2.0.4"
update_interval: 5s
# Define a domain for this device to use. i.e. iot.home.lan (so device will appear as athom-smart-plug-v2.iot.home.lan in DNS/DHCP logs)
dns_domain: ""
# Set timezone of the smart plug. Useful if the plug is in a location different to the HA server. Can be entered in unix Country/Area format (i.e. "Australia/Sydney")
timezone: ""
# Set the duration between the sntp service polling ntp.org servers for an update
sntp_update_interval: 6h
# Network time servers for your region, enter from lowest to highest priority. To use local servers update as per zones or countries at: https://www.ntppool.org/zone/@
sntp_server_1: "0.pool.ntp.org"
sntp_server_2: "1.pool.ntp.org"
sntp_server_3: "2.pool.ntp.org"
# Enables faster network connections, with last connected SSID being connected to and no full scan for SSID being undertaken
wifi_fast_connect: "false"
# Define logging level: NONE, ERROR, WARN, INFO, DEBUG (Default), VERBOSE, VERY_VERBOSE
log_level: "DEBUG"
# Enable or disable the use of IPv6 networking on the device
ipv6_enable: "false"
#############################ESP32C3###########################
bl0906_tx_pin: GPIO7
bl0906_rx_pin: GPIO8
button_pin: GPIO9
led_pin: GPIO10
clk_pin: GPIO2
mosi_pin: GPIO3
backlight_pin: GPIO18
reset_pin: GPIO4
dc_pin: GPIO5
cs_pin: GPIO6
#############################ESP32C3###########################
esphome:
name: "${name}"
friendly_name: "${friendly_name}"
area: "${room}"
name_add_mac_suffix: true
min_version: 2024.9.2
project:
name: "${project_name}"
version: "${project_version}"
esp32:
board: esp32-c3-devkitm-1
flash_size: 4MB
variant: ESP32C3
framework:
type: arduino
version: recommended
preferences:
flash_write_interval: 5min
api:
# reboot_timeout: 0s
ota:
- platform: esphome
logger:
baud_rate: 115200
level: ${log_level}
hardware_uart: UART0
mdns:
disabled: false
web_server:
port: 80
network:
enable_ipv6: ${ipv6_enable}
wifi:
ap: {}
fast_connect: "${wifi_fast_connect}"
domain: "${dns_domain}"
captive_portal:
improv_serial:
esp32_improv:
authorizer: none
dashboard_import:
package_import_url: github://athom-tech/esp32-configs/athom-energy-monitor-x2.yaml
globals:
- id: id_Energy_sum_persist
type: float
restore_value: yes
initial_value: '0.0'
- id: id_Energy_sum_lastvalue
type: float
restore_value: no
initial_value: '0.0'
- id: id_Energy_1_persist
type: float
restore_value: yes
initial_value: '0.0'
- id: id_Energy_1_lastvalue
type: float
restore_value: no
initial_value: '0.0'
- id: id_Energy_2_persist
type: float
restore_value: yes
initial_value: '0.0'
- id: id_Energy_2_lastvalue
type: float
restore_value: no
initial_value: '0.0'
uart:
tx_pin: "$bl0906_tx_pin"
rx_pin: "$bl0906_rx_pin"
baud_rate: 19200
id: uart_bl0906
light:
- platform: status_led
name: "Status LED"
id: blue_led
disabled_by_default: true
pin: $led_pin
binary_sensor:
- platform: status
name: "Status"
entity_category: diagnostic
- platform: gpio
pin:
number: "$button_pin"
mode: INPUT_PULLUP
inverted: true
name: "Power Button"
disabled_by_default: true
on_multi_click:
- timing:
- ON for at least 4s
then:
- button.press: Reset
sensor:
- platform: uptime
name: "Uptime Sensor"
id: uptime_sensor
entity_category: diagnostic
internal: true
- platform: wifi_signal
name: "WiFi Signal dB"
id: wifi_signal_db
update_interval: 60s
entity_category: "diagnostic"
- platform: copy
source_id: wifi_signal_db
name: "WiFi Signal Percent"
filters:
- lambda: return min(max(2 * (x + 100.0), 0.0), 100.0);
unit_of_measurement: "Signal %"
entity_category: "diagnostic"
device_class: ""
- platform: bl0906
id: id_bl0906
update_interval: "${update_interval}"
frequency:
name: 'Frequency'
id: 'Frequency'
temperature:
name: 'Temperature'
id: 'Temperature'
voltage:
name: 'Voltage'
id: 'Voltage'
channel_1:
current:
name: 'Current_1'
id: 'Current_1'
power:
name: 'Power_1'
id: 'Power_1'
energy:
id: 'Energy_1'
name: 'Energy_1_Internal'
internal: true
channel_2:
current:
name: 'Current_2'
id: 'Current_2'
power:
name: 'Power_2'
id: 'Power_2'
energy:
id: 'Energy_2'
name: 'Energy_2_Internal'
internal: true
total_energy:
name: 'Total_Energy'
id: 'Energy_sum'
internal: true
total_power:
name: 'Total_Power'
id: 'Tatal_Power'
- platform: copy
name: 'Total_Energy'
id: Energy_sum_persist
source_id: Energy_sum
filters:
- lambda: |-
if(id(id_Energy_sum_lastvalue) == 0.0 )
{
id(id_Energy_sum_lastvalue) = id(Energy_sum).state;
}
if(x < id(id_Energy_sum_persist))
{
float delta = x - id(id_Energy_sum_lastvalue);
id(id_Energy_sum_persist) += delta;
id(id_Energy_sum_lastvalue) = x;
}
else
{
id(id_Energy_sum_persist) = x;
}
return id(id_Energy_sum_persist);
- platform: copy
name: 'Energy_1'
id: Energy_1_persist
source_id: Energy_1
filters:
- lambda: |-
if(id(id_Energy_1_lastvalue) == 0.0 )
{
id(id_Energy_1_lastvalue) = id(Energy_1).state;
}
if(x < id(id_Energy_1_persist))
{
float delta = x - id(id_Energy_1_lastvalue);
id(id_Energy_1_persist) += delta;
id(id_Energy_1_lastvalue) = x;
}
else
{
id(id_Energy_1_persist) = x;
}
return id(id_Energy_1_persist);
- platform: copy
name: 'Energy_2'
id: Energy_2_persist
source_id: Energy_2
filters:
- lambda: |-
if(id(id_Energy_2_lastvalue) == 0.0 )
{
id(id_Energy_2_lastvalue) = id(Energy_2).state;
}
if(x < id(id_Energy_2_persist))
{
float delta = x - id(id_Energy_2_lastvalue);
id(id_Energy_2_persist) += delta;
id(id_Energy_2_lastvalue) = x;
}
else
{
id(id_Energy_2_persist) = x;
}
return id(id_Energy_2_persist);
button:
- platform: restart
name: "Restart"
entity_category: config
- platform: factory_reset
name: "Factory Reset"
id: Reset
entity_category: config
- platform: safe_mode
name: "Safe Mode"
internal: false
entity_category: config
- platform: template
name: Reset Energy
entity_category: config
on_press:
then:
- globals.set:
id: id_Energy_1_persist
value: '0.0'
- globals.set:
id: id_Energy_2_persist
value: '0.0'
- globals.set:
id: id_Energy_sum_persist
value: '0.0'
- bl0906.reset_energy: id_bl0906
text_sensor:
- platform: wifi_info
ip_address:
name: "IP Address"
id: ip_address
entity_category: diagnostic
ssid:
name: "Connected SSID"
id: ssid
entity_category: diagnostic
mac_address:
name: "Mac Address"
id: mac_address
entity_category: diagnostic
- platform: template
name: "Last Restart"
id: device_last_restart
icon: mdi:clock
entity_category: diagnostic
device_class: timestamp
- platform: template
name: "Uptime"
id: uptimes
icon: mdi:clock-start
entity_category: diagnostic
lambda: |-
int seconds = (id(uptime_sensor).state);
int days = seconds / (24 * 3600);
seconds = seconds % (24 * 3600);
int hours = seconds / 3600;
seconds = seconds % 3600;
int minutes = seconds / 60;
seconds = seconds % 60;
if ( days > 3650 ) {
return { "Starting up" };
} else if ( days ) {
return { (String(days) +"d " + String(hours) +"h " + String(minutes) +"m "+ String(seconds) +"s").c_str() };
} else if ( hours ) {
return { (String(hours) +"h " + String(minutes) +"m "+ String(seconds) +"s").c_str() };
} else if ( minutes ) {
return { (String(minutes) +"m "+ String(seconds) +"s").c_str() };
} else {
return { (String(seconds) +"s").c_str() };
}
time:
- platform: sntp
id: sntp_time
# Define the timezone of the device
timezone: "${timezone}"
# Change sync interval from default 5min to 6 hours (or as set in substitutions)
update_interval: ${sntp_update_interval}
# Set specific sntp servers to use
servers:
- "${sntp_server_1}"
- "${sntp_server_2}"
- "${sntp_server_3}"
# Publish the time the device was last restarted
on_time_sync:
then:
# Update last restart time, but only once.
- if:
condition:
lambda: 'return id(device_last_restart).state == "";'
then:
- text_sensor.template.publish:
id: device_last_restart
state: !lambda 'return id(sntp_time).now().strftime("%a %d %b %Y - %I:%M:%S %p");'