Openinverter Web Interface Protocol

This document describes the protocol used on the serial interface between this ESP8266 module, and an inverter or VCU.

General

Commands are sent by the ESP8266. Each command consists of a single line consisting of a command word followed optionally by parameters and terminates with a newline character. Commands must be echoed back to the ESP8266.

Following the echo, the esp8266 will receive an unlimited quantity of response data, terminated by a 100ms timeout.

Except where otherwise noted, the responses are free text and should generally contain a single human readable line indicating success or failure of the operation.

Parameters and other data

Openinverter makes available two types of data - parameters and non-parameters.

Parameters are user configurable values, generally used for configuration. They can be stored in nonvolatile memory and should not change except in response to a user request.

Other values are made available that are not configurable, but are instead indicative of the immediate state of the inverter. These are useful for monitoring and debugging.

Commands

Command Description
save save current parameters to nonvolatile memory
load load parameters from nonvolatile memory
fastuart increases the baud rate to 921600Response must begin "OK" in success case
set [parameter] [value] set the decimal value of a named parameter
can [direction] [name] [canid] [offset] [length] [gain] map values to CAN messages
can clear clear all can mappings
start [opmode] start the inverter in a specified mode. Mode 2 is manual run
stop stop the inverter
get [parameter] get the value of a parameter
stream [repetitions] [val1,val2,val3] repeatedly read and return one or more values
json [hidden] return an JSON encoded mapping of all parameters and values - see JSON format below
errors print information about all currently active error states, or indicate that everything is okay
reset reboot the device
defaults restore all parameters to default values

Note: This is not an exhaustive list of commands supported by openinverter devices, but does include all commands currently used by the openinverter web intrface.

JSON Mapping

The json command requests a dump of the full schema and values of both the configurable parameters and other available data. The optional "hidden" flag requests data that would not normally be displayed to the user.

The following example shows a non-parameter value, a parameter value, and a value that has been mapped to CAN.

{
  "udc":   {"unit":"V",   "value": 400.0,  "isparam": false},
  "fweak": {"unit":"Hz",  "value": 67.0,   "isparam": true, "minimum": 0.0, "maximum": 400.0, "default": 67.0, "category": "Motor (sine)", "i": 8},
  "speed": {"unit":"rpm", "value": 1000.0, "isparam": false, "canid": 123, "canoffset":0, "canlength":32, "cangain":5, "isrx": false}
}