forked from markito3/gluex-nim
-
Notifications
You must be signed in to change notification settings - Fork 0
/
solenoid.tex
326 lines (298 loc) · 15.8 KB
/
solenoid.tex
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
%=======================+=========================
%================ Solenoid ================
%=================================================
\section[Solenoid Magnet]{Solenoid magnet
\label{sec:solenoid}
}
\subsection[Overview]{Overview \label{sec:sol:overview}
}
The core of the \gx{} spectrometer is a superconducting
solenoid with a bore diameter and overall yoke length of approximately 2~m and 4.8~m, respectively. The photon beam passes along the axis of
the solenoid. At the nominal current of 1350~A, the magnet provides a magnetic field along the axis of about 2~T.
The magnet was designed and built at SLAC in the early
1970's~\cite{Alcorn-confer-1972} for the LASS
spectrometer~\cite{Aston:1987uc}. The solenoid employs a cryostatically
stable design with cryostats designed to be opened and
serviced with hand tools. The magnet was refurbished and modified%
\footnote{
The front plate of the flux return yoke was modified, leading to a
swap of the two front coils and modifications of the return flux
yoke in order to keep the magnetic forces on the front coil under
the design limit. The original gaps between the yoke's rings were
filled with iron. The Cryogenic Distribution Box was designed and
built for \gx{}.
}
for the \gx{} experiment~\cite{Ballard:2011tm, Ballard:2015wma}.
The magnet is constructed of four separate superconducting coils and
cryo\-stats. The flux return yoke is made of several iron rings. The
coils are connected in series. A common liquid helium tank is located
on top of the magnet, providing a gravity feed of the liquid to the
coils. The layout of the coil cryostats and the flux return iron
yoke is shown in Fig.~\ref{fig:layout_spectrometer}.
Table~\ref{tab:sol:summary} summarizes the salient parameters of the magnet.
% ======================================================================================
\begin{table}[thp]
\begin{center}
\small
\begin{tabular}{lr}
\hline
\hline
Inside diameter of coils & 2032 mm \\
Clear bore diameter & 1854 mm \\
Overall length along iron & 4795~mm \\
Inside iron diameter & 2946~mm \\
Outside iron diameter & 3759~mm \\
Original yoke, cast and annealed - steel & AISI 1010 \\
Added filler plates - steel & ASTM A36 \\
Full weight & 284~t \\
Full number of turns & 4608 \\
Number of separate coils & 4 \\
% Longitudinal arrangement of coils & 1-2-3-4 & & 2-1-3-4 \\
Turns per coil 2 & 928 \\
Turns per coil 1 & 1428 \\
Turns per coil 3 & 776 \\
Turns per coil 4 & 1476 \\
Total conductor weight & 13.15 t \\
Coil resistance at $\sim$300~K & 15.3~$\Omega$ \\
Coil resistance at $\sim$10~K & $\sim$0.15~$\Omega$ \\
Design operational current & 1500 A \\
Nominal current (actual) & 1350 A \\
Maximal central field at 1350~A & 2.08 T \\
Inductance at 1350~A & 26.4 H \\
Stored energy at 1350~A & 24.1 MJ \\
Protection circuit resistor & 0.061 $\Omega$ \\
% Total conductor length & 117600 ft & 35.84 km & {\it same} \\
% Substrate material & \multicolumn{1}{r}{Copper} & & {\it same} \\
% Copper-to-filament ratio (A) & \multicolumn{1}{r}{20:1} & & {\it same} \\
% Copper-to-filament ratio (B) & \multicolumn{1}{r}{28:1} & & {\it same} \\
Coil cooling scheme & helium bath \\
Total liquid helium volume & 3200 $\ell$ \\
Operating temperature (actual) & 4.5~K \\
Refrigerator liquefaction rate at 0~A & 1.7~g/s \\
Refrigerator liquefaction rate at 1350~A & 2.7~g/s \\
% Refrigerator liquefaction rate at 0~A & 1.7~g\thinspace{}s$^{-1}$ \\
% Refrigerator liquefaction rate at 1350~A & 2.7~g\thinspace{}s$^{-1}$ \\
% Protection circuit limiting voltage & 500 V & & 90 V \\
\hline
\end{tabular}
\normalsize
\end{center}
\caption{
Key parameters of the \gx{} solenoid. The
coils are listed in order along the beam direction.
\label{tab:sol:summary}
}
\end{table}
\subsection[Conductor and Coils]{Conductor and Coils
\label{sec:sol:coils}
}
The superconductor composite is made of niobium--titanium filaments
%\footnote{The critical temperature is about 10$^\circ$K.}
in a copper substrate, twisted and shaped into a
$\sim$7.62$\times$1~mm$^2$ rectangular band. The laminated conductor
is made by soldering the superconductor composite band between two
copper strips
%\footnote{Copper CDA 102. Average Resistivity Ratio for
% 300$^\circ$K:4.2$^\circ$K is a minimum of 150:1, claimed by the builders of the
% magnet\cite{Solen-conductor}.
% %It contradicts the data from another
% %source\cite{CuHandbook}, which specifies $10<$RRR$<100$ for ETP
% %copper.
% Our measurements show RRR$\approx{}$100.
%}
to form a rectangular cross section of 7.62$\times$5.33~mm$^2$.
%\cite{Alcorn-confer-1972}.
The measured residual resistivity ratio of the conductor at $\sim{}300$K and
$\sim{}15$K is $\approx{}$100.
%Two types of filaments have
%been used (see Fig.~\ref{fig:sol:conductor-cartoon} and
%Table.~\ref{tab:sol:conductor}). The Grade A conductor provides a higher
%current limit than the Grade B conductor and is used in the area of
%the highest magnetic field (Coil 4).
%The coil was wound on G-10 standoff strips glued on the cylindrical
%inner wall of the liquid helium vessel.
As the coil was wound, a 0.64~mm-thick stainless steel support band
and two 0.2~mm-thick Mylar insulating strips were wound together with it
for pre-tensioning and insulation%
%(Fig.~\ref{fig:sol:conductor-cartoon})
.
The liquid helium is in contact with the shorter (5.33~mm) sides of
the cable.
Each of the coils consists of a number of subcoils. Each subcoil
contains a number of ``double pancakes'' with the same number of
turns.
%(see Table~\ref{tab:sol:coils-turns}).
Each double pancake is made from a single piece of conductor. The
voltage across the subcoils is monitored using special wires. These pass
through vertical cryostats, called chimneys, along with the helium supply pipes and the
main conductor.
The cold helium vessel containing the coil is supported within the
warm cryostat vacuum vessel by a set of columns designed to provide
sufficient thermal insulation. The columns are equipped with strain
gauges for monitoring the stresses on the columns. The helium vessel
is surrounded by a nitrogen-cooled thermal shield made of copper and stainless-steel panels.
Super-insulation is placed between the vacuum vessel and the nitrogen
shield. The vacuum vessels are attached to the matching iron rings of
the yoke.
The power supply%
\footnote{Danfysik System 8000 Type 854.}
provides up to 10~V DC for establishing the operating current while ramping. The supply also
includes a protection circuit, which can be engaged by a quench
detector as well as by other signals. During trips, a small dump resistor
of 0.061~$\Omega$ limits the maximum voltage on the magnet to 100~V. The dumping time constant of $L/R \approx 7$~min is
relatively long, but safe according to the original design of the
magnet. A large copper mass and the helium bath are able to absorb a
large amount of energy during a quench without overheating the solder
joints. This permits the use of an ``intelligent'' quench detector with low noise sensitivity and a relatively slow decision time of 0.5~s. The quench detector compares the measured voltages on different subcoils
in order to detect a resistive component.
%The decision is made based on the measured voltages on the
%subcoils.
While ramping the current, such a voltage is proportional
to the subcoil inductance. Relative values of inductance of various
subcoils depend on the value of the current because of saturation
effects in the iron yoke. Transient effects are also present at changes
of the slew rate caused by Foucault currents in the yoke.
%The quench detector compares
%voltages on different subcoils in order to detect a resistive
%component that might appear in a subcoil.
The system includes two redundant detectors: one uses analog signals
and a simplified logic, another is part of the PLC control system (see
Section~\ref{sec:sol:controls}) which uses digitized signals. The PLC
digital programmable device is more sensitive since this monitoring system takes into
account the dependence of the coils' inductance on the current and
provides better noise filtering. The ramping slew rate is
limited by the transient imbalance of the voltages on subcoils that
may trigger the quench detector. Additionally,
unexplained voltage spikes of 1~ms duration
have been observed in coil 2 at high
slew rates, which can trigger the quench detector. Powering up the
magnet to 1350~A takes about 8~h.
For diagnostic purposes two 40-turn pickup coils are installed on the bore
surface of the vacuum vessel of each of the coils.
\subsection[Cooling System]{
Cooling System
\label{sec:sol:cryo}
}
The cooling system is described in detail in Ref.~\cite{Lavendure:2014:refrig}.
A stand-alone helium refrigerator located
in a building adjacent to Hall D provides liquid helium and nitrogen
via a transfer line to the Cryogenic Distribution Box above the
magnet. The transfer line delivers helium at 2.6~atm, and 6~K to a Joule-Thomson
(JT) valve providing liquid to a cylindrical common helium tank in the
Distribution Box. The level of liquid helium in the tank is measured
with a superconducting wire probe;%
\footnote{
American Magnetics Model 1700 with HS-1/4-RGD-19"/46"-4LDCP-LL6-S sensor
}
the liquid level is kept at about half of the tank diameter. The cold helium gas
from the tank is returned to the refrigerator, which keeps the
pressure at the top of the tank at 1.2~atm corresponding to about
4.35~K at the surface of the liquid.%
\footnote{
The original implementation at SLAC did not recycle the helium and
operated at atmospheric pressure.
}
Each coil is connected to the common helium tank by two vertical 2-inch
pipes. One pipe is open at the bottom of the tank while the other one
is taller than the typical level of helium inside the tank. The main
conductor and the wires for voltage monitoring pass through the former
pipe. Additionally, two $\sim$6~m long, 3/8~inch ID pipes go outside
the coil's helium vessel, from the Distribution Box to the bottom of
the coil. One of those pipes, connected to a JT valve in the box, is used to fill the coil initially, but is not used during operation.
The other pipe reaches the bottom of
the common helium tank in order to provide
a thermo-syphon effect essential
for the proper circulation of helium in the coil. The main current is
delivered into the helium tank via vapor-cooled leads, and is
distributed to the coils by a superconducting cable. After cooling the
leads, the helium gas is warmed and returned to the refrigeration
system. The gas flow through the leads is regulated based on the
current in the magnet; at 1350~A, the flow is about 0.25~g/s. The
coils and the Distribution Box are equipped with various sensors for
temperature, pressure, voltage, and flow rates.
\subsection[Measurements and Controls]{
Measurements and Controls
\label{sec:sol:controls}
}
The control system for the superconducting solenoid, power supply,
and cryogenic system, is based on Programmable Logic
Controllers (PLC)%
\footnote{
Allen-Bradley Programmable Logic Controllers
\url{http://ab.rockwellautomation.com/Programmable-Controllers}.
}%
.
The PLC system digitizes the signals from various sensors, communicates with
other devices, reads out the data into a programmable unit for
analysis, and sends commands to various devices. Additionally, the PLC is
connected to EPICS\footnote{Experimental Physics and
Industrial Control System, https://epics.anl.gov.} in order to display and archive the data (see
Section \ref{sec:controls}). The practical sampling limit for the readout of the sensor
is a few Hz, which is too low for
detection of fast voltage spikes on the coils due to motion, shorts,
or other effects. Therefore, the voltage taps from the coils and the pickup coils are read
out by a PXI system\footnote{
National Instruments, PXI Platform, \url{http://www.ni.com/pxi/}.
}, which provides a sampling rate of about 100~kHz. The
PXI system also reads out several accelerometers attached to the
coils' chimneys, which can detect motion inside the coils. The PXI
CPU performs initial integration and arranges the data in time-wise
rows with a sampling rate of 10~kHz. The PLC system reads out the
data from the PXI system. Additionally, the PXI data are read out by
an EPICS server at the full 10~kHz sampling rate and are recorded for further analysis.
\subsection[Field calculation and measurement]{
Field calculation and measurement
\label{sec:sol:field}
}
The momentum resolution of the \gx{} spectrometer is larger than
1\% and is dominated by multiple scattering and the spatial
resolution of the coordinate detectors. Thus, a fraction of a percent is
sufficient accuracy for the field determination. The coils are
axially symmetric, while the flux return yoke is nearly axially
symmetric, apart from the holes for the chimneys. The field was
calculated using a 2-dimensional field calculator {\it
Poisson/Superfish}%
\footnote{
Poisson/Superfish developed at LANL,
\url{https://laacg.lanl.gov/laacg/services/serv_codes.phtml\#ps}.
}
, assuming axial symmetry. The model of the magnet included the
fine structure of the subcoils and the geometry of the yoke
iron. Different assumptions about the magnetic properties of the yoke
iron have been used: the {\it Poisson} default AISI 1010 steel, the
measurements of the original yoke iron made at SLAC, and the 1018
steel used for the filler plates. Since the results of the field
calculations differ by less than 0.1\%, the default {\it Poisson} AISI
1010 steel properties were used for the whole yoke iron in the final
field map calculations.
The three projections of the magnetic field have been measured along lines
parallel to the axis, at four values of the radius and at up to six values
of the azimuthal angle. The calculated field and the measured deviations are shown in Fig.~\ref{fig:sol:field_comparison}. The
tracking detectors occupy the volume of $R<56$~cm and $45<Z<340$~cm. In
this volume the field deviation at $R=0$ does not exceed 0.2\%. The
largest deviation of 1.5\% is observed at the downstream edge of the
fiducial volume and at the largest radius. Such a field uncertainty in
that region does not noticeably affect the momentum resolution. In
most of the fiducial volume the measured field is axially symmetric to
$\approx$0.1\% and deviates from this symmetry by $\approx$2\% at the
downstream edge and the largest radius.
The calculated field map is used for track reconstruction and
physics analyses.
% ======================================================================================
%\begin{figure}[tp]
\begin{figure}[!htb]
\begin{center}
\includegraphics[angle=0,width=1.0\linewidth]{figures/solenoid_field_calc-meas_comparison_7_1_01}%
\end{center}
\caption{
The full field at 1350~A calculated with {\it Poisson} (left
scale) on the axis and at the edge of the tracking fiducial volume (R=56~cm). The deviations of the measurements from the
calculations are shown (right scale) on the axis, and at R=56~cm. The measurements were made at 6 azimuthal
angles. We show the angles (0$^\circ$ and 90$^\circ$) with the largest deviations from the
calculations.
% In the area most important for tracking $45<Z<320$~cm the
% deviations from the calculations are below 0.5\%.
\label{fig:sol:field_comparison}
}
\end{figure}
% ----------------------------------------------------------------------