94
95
96
97
"""
swat-s1 plc3
"""
from minicps.devices import PLC
from utils import PLC3_DATA, STATE, PLC3_PROTOCOL
from utils import PLC_SAMPLES, PLC_PERIOD_SEC
from utils import IP
import time
import shlex
import subprocess
from cpppo.server.enip.get_attribute import proxy_simple
PLC1_ADDR = IP['plc1']
PLC2_ADDR = IP['plc2']
PLC3_ADDR = IP['plc3']
LIT301_3 = ('LIT301', 3)
class SwatPLC3(PLC):
def pre_loop(self, sleep=0.1):
print 'DEBUG: swat-s1 plc3 enters pre_loop'
print
time.sleep(sleep)
def main_loop(self):
"""plc3 main loop.
- read UF tank level from the sensor
- update internal enip server
"""
# Start enip server with dummy values (to be updated for each "PLC_SAMPLE" loop)
tag_string = 'LIT301:3@22/1/3=REAL'
cmd = shlex.split(
'enip_server --print' +
' ' + tag_string
)
# print 'DEBUG enip _send cmd shlex list: ', cmd
# Start server in the background
try:
client = subprocess.Popen(cmd, shell=False)
# client.wait()
for i in range (0, 1):
time.sleep(1)
print 'DEBUG plc3 - waiting %d seconds for server to start' % i
except Exception as error:
print 'ERROR plc3 error starting server: ', error
exit(1)
via = proxy_simple('192.168.1.30')
fit201_tag = '@22/1/3'
count = 0
while(count <= PLC_SAMPLES):
lit301 = float(self.get(LIT301_3))
print "DEBUG PLC3 - get lit301: %f" % lit301
# self.send(LIT301_3, lit301, PLC3_ADDR)
# with via: result, = via.read([(fit301_tag + '=(REAL)' + str(lit301), fit301_tag)])
with via: result, = via.read([(fit201_tag + '=(REAL)' + str(lit301), fit201_tag)])
print 'this is the return value: %s' % result
# send_status = self.send(LIT301_3, lit301, PLC1_ADDR)
# print "DEBUG PLC3 - send lit301: %f" % lit301
# if send_status == None or TypeError:
# print "\n\n\n\n\nDEBUG PLC2 - FAILED TO SEND", LIT301_3, ":", lit301, "TO", PLC1_ADDR, ": LIT301_3 is not tuple"
# print "type of LIT301_3: ", type(LIT301_3)
# else:
# print "\n\n\n\n\nDEBUG PLC2 - send lit301: %f\n\n\n\n\n" % lit301
time.sleep(PLC_PERIOD_SEC)
count += 1
print 'DEBUG swat plc3 shutdown'
if __name__ == "__main__":
# notice that memory init is different form disk init
plc3 = SwatPLC3(
name='plc3',
state=STATE,
protocol=PLC3_PROTOCOL,
memory=PLC3_DATA,
disk=PLC3_DATA)