SWaT sub1 physical process
T101 has an inflow pipe and outflow pipe, both are modeled according
to the equation of continuity from the domain of hydraulics
(pressurized liquids) and a drain orefice modeled using the Bernoulli's
principle (for the trajectories).
"""
from minicps.devices import Tank
from utils import TANK_SECTION, SYSTEM_FLOWRATE_OUT_METER_CUBED
from utils import LIT_101_M, LIT_301_M, T301_INIT_LEVEL
from utils import STATE, PP_PERIOD_SEC, PP_PERIOD_HOURS, PP_SAMPLES
import time
# SPHINX_SWAT_TUTORIAL TAGS(
MV101 = ('MV101', 1)
P101 = ('P101', 1)
LIT101 = ('LIT101', 1)
LIT301 = ('LIT301', 3)
FIT101 = ('FIT101', 1)
FIT201 = ('FIT201', 2)
# SPHINX_SWAT_TUTORIAL TAGS)
# TODO: implement orefice drain with Bernoulli/Torricelli formula
class T301(Tank):
# def pre_loop(self):
# SPHINX_SWAT_TUTORIAL STATE INIT(
# self.level = self.set(LIT301, 1.0)
# SPHINX_SWAT_TUTORIAL STATE INIT)
# test underflow
# self.set(MV101, 0)
# self.set(P101, 1)
# self.level = self.set(LIT101, 0.500)
def main_loop(self):
count = 0
while(count <= PP_SAMPLES):
lit301 = self.get(LIT301)
fit201 = self.get(FIT201)
new_level = self.level
# compute water volume
water_volume = self.section * new_level
# inflows volumes
# TODO: put "float(lit301) < LIT_301_M['LL']" in PLC1
inflow = float(fit201) * PP_PERIOD_HOURS # PUMP_FLOWRATE_OUT replictes outflow from raw water tank
print "DEBUG T301 inflow: ", inflow
water_volume += inflow
# outflows volumes
# self.set(FIT201, PUMP_FLOWRATE_OUT)
outflow = SYSTEM_FLOWRATE_OUT_METER_CUBED * PP_PERIOD_HOURS
print "DEBUG T301 outflow: ", outflow
water_volume -= outflow
# compute new water_level
new_level = water_volume / self.section
# level cannot be negative
if new_level <= 0.0:
new_level = 0.0
# update internal and state water level
print "DEBUG FIT301 new_level: %.5f \t delta: %.5f" % (
new_level, new_level - self.level)
self.level = self.set(LIT301, new_level)
# 988 sec starting from 0.500 m
if new_level >= LIT_301_M['HH']:
print 'DEBUG T301 above HH count: ', count
break
# 367 sec starting from 0.500 m
elif new_level <= LIT_101_M['LL']:
print 'DEBUG T301 below LL count: ', count
break
count += 1
time.sleep(PP_PERIOD_SEC)
if __name__ == '__main__':
t301 = T301(
name='t301',
state=STATE,
protocol=None,
section=TANK_SECTION,
level=T301_INIT_LEVEL
)