Notifications
You must be signed in to change notification settings - Fork 9
/
00-configure-hp-hba-mode.sh
190 lines (137 loc) · 6.43 KB
/
00-configure-hp-hba-mode.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
#!/bin/bash
#
# Foundation Cloud Infrastructure Setup Script for HP Smart Array CLI
#
# This script configures HP Smart Array Controllers
#
# Copyright (C) 2019 Canonical Ltd.
#
# Authors: Craig Bender <[email protected]>
#
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, version 3 of the License.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
#
#
#Exit script if non-hp hardware detected
NODE_VENDOR="$(dmidecode -s system-manufacturer)"
[[ ${NODE_VENDOR} = HP ]] || { printf "Non-HP Server Detected, exiting.\n" 2>&1;exit 0; }
#Get the Server Model incase we have to run a different utility other than hpssacli
export NODE_MODEL="$(dmidecode -s system-product-name)"
printf "Detected ${NODE_VENDOR} ${NODE_MODEL}\n" 2>&1
#Download repository keys and package for HP SSA Client
export SCMD=sudo
printf "Installing HP Utilities\n" 2>&1
sh -c "echo 'deb http://downloads.linux.hpe.com/SDR/repo/mcp xenial/current non-free' > /etc/apt/sources.list.d/mcp.list"
sh -c "echo 'deb http://downloads.linux.hpe.com/SDR/repo/hprest xenial/current non-free' > /etc/apt/sources.list.d/hprest.list"
curl -s https://downloads.linux.hpe.com/SDR/hpPublicKey1024.pub |apt-key add - > /dev/null 2>&1
curl -s https://downloads.linux.hpe.com/SDR/hpPublicKey2048.pub |apt-key add - > /dev/null 2>&1
curl -s https://downloads.linux.hpe.com/SDR/hpPublicKey2048_key1.pub |apt-key add - > /dev/null 2>&1
curl -s https://downloads.linux.hpe.com/SDR/hpePublicKey2048_key1.pub |apt-key add - > /dev/null 2>&1
apt update
DEBIAN_FRONTEND=noninteractive apt install hponcfg hprest hpssacli hpssa linux-image-extra-$(uname -r) --no-install-recommends -y
sudo apt dist-upgrade -y
modprobe hpilo
#Check if packages downloaded has already been downloaded, otherwise add to pkg list
command -v hpssacli > /dev/null 2>&1 || { printf "hpssacli failed to download\n" 2>&1; exit 0; }
[[ -n $(lsmod|grep hpilo) ]] || { printf "hpilo kernel mod failed to load\n" 2>&1; exit 0; }
[[ $(dpkg -l linux-image-extra-$(uname -r)|awk '/linux/{print $2}') = linux-image-extra-$(uname -r) ]] || { printf "linux-image-extra-$(uname -r) failed to download\n" 2>&1; exit 0; }
#Run commands based on server model
declare -a CONTROLLERS=($(hpssacli ctrl all show|grep -Po '(?<=Slot )[^ ]+'))
for ctl in ${CONTROLLERS[@]};do
#Get Controller Model
export CTL_MODEL="$(hpssacli controller slot=${ctl} show|grep -m1 -Po '(?<=^)[^in]+'|sed -E 's/^ | $//g')"
printf "Current config for Controller ${ctl} (${CTL_MODEL})\n" 2>&1
hpssacli controller slot=${ctl} show config
#
##
### Delete Any logical Drives
##
#
printf "Checking for logical drives on ${CTL_MODEL}\n" 2>&1
LD_ARR=($(hpssacli ctrl slot=${ctl} show config |awk '/logicaldrive/{print $2}'))
printf "Discovered ${#LD_ARR[@]} logical drives on ${CTL_MODEL}\n" 2>&1
for l in ${LD_ARR[@]}; do
printf "Deleting Logical Drive ${l} from the ${CTL_MODEL} controller in slot ${ctl}\n" 2>&1
printf 'y\n'|hpssacli ctrl slot=${ctl} ld ${l} delete
done
#
##
### Enable True HBA Mode for Controllers that support it
##
#
if [[ ${CTL_MODEL} != "Smart HBA H240ar" ]];then
printf "Attempting to enable HBA Mode on ${HOST}: ${NODE_MODEL}\n" 2>&1
#These commands should work for all other HP Controllers, but were tested on XL420
printf 'y\n'|hpssacli controller slot=${ctl} modify hbamode=off forced
printf 'y\n'|hpssacli controller slot=${ctl} modify hbamode=on forced
printf 'y\n'|hpssacli controller slot=${ctl} modify hbamode=off forced
printf 'y\n'|hpssacli controller slot=${ctl} modify hbamode=on forced
sleep 2
#The following value will be true if successful
export HBA_ENABLED=$(hpssacli controller slot=${ctl} show|awk '/HBA Mode Enabled:/{print $NF}')
[[ ${HBA_ENABLED} = True ]] && printf "HBA Mode enabled for the ${CTL_MODEL} controller on ${HOST}: Model=${NODE_MODEL}\n" 2>&1
#
##
### Enable AHCI mode (Ubuntu does not support Dynamic RAID on the Smart HBA H240ar)
##
#
elif [[ ${CTL_MODEL} = "Smart HBA H240ar" ]];then
if [[ "$(hprest get EmbeddedSata --selector HpBios.|grep -m1 -Po '(?<=EmbeddedSata=)[^$]+'|sed -E 's/^ | $//g')" != Ahci ]];then
printf "Enabling AHCI mode on ${CTL_MODEL}\n" 2>&1
hprest set EmbeddedSata=Ahci --selector HpBios --commit
sleep 1
else
printf "AHCI already enabled for the ${CTL_MODEL} controller on ${HOST}: Model=${NODE_MODEL}\n" 2>&1
fi
#
##
### Original Mode
### --------------
### /dev/sda (Single-Drive Logical Disk - RAID 0)
### /dev/sdb (Four-Drive Logical Disk - RAID 0)
##
#
printf "Building RAID Configuration on ${CTL_MODEL}\n" 2>&1
printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:1 raid=0 stripsize=128
printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:2,1I:1:3,1I:1:4,2I:1:5 raid=0 stripsize=128
#
##
### Big Disk Mode
### --------------
### /dev/sda (Five-Drive Logical Disk - RAID 0)
##
#
#printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:1,1I:1:2,1I:1:3,1I:1:4,2I:1:5 raid=0 stripsize=128
#
##
### Fake JBOD
### ----------
### /dev/sda (Single-Drive Logical Disk, RAID 0)
### /dev/sdb (Single-Drive Logical Disk, RAID 0)
### /dev/sdc (Single-Drive Logical Disk, RAID 0)
### /dev/sdd (Single-Drive Logical Disk, RAID 0)
### /dev/sde (Single-Drive Logical Disk, RAID 0)
##
#
#printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:1 raid=0 stripsize=128
#printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:2 raid=0 stripsize=128
#printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:3 raid=0 stripsize=128
#printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=1I:1:4 raid=0 stripsize=128
#printf 'y\n'|hpssacli ctrl slot=${ctl} create type=ld drives=2I:1:5 raid=0 stripsize=128
fi
printf "New config for Controller ${ctl} (${CTL_MODEL})\n" 2>&1
hpssacli controller slot=${ctl} show config 2>&1
unset HBA_ENABLED CTL_MODEL
done
printf "${0##*/} Complete\n" 2>&1
sleep 1
exit 0