Skip to content

Latest commit

 

History

History
22 lines (15 loc) · 1.36 KB

programmers_guide.md

File metadata and controls

22 lines (15 loc) · 1.36 KB

Programmer's Guide

Software will mostly interact with the ROM controller by fetching code or loading data from ROM. For this, the block looks like a block of memory, accessible through a TL-UL window. However, there are a few registers that are accessible. Other than the standard ALERT_TEST register, all are read-only.

The FATAL_ALERT_CAUSE register might change value during operations (if an alert is signalled), but the other registers will all have fixed values by the time any software runs.

To get the computed ROM digest, software can read DIGEST_0 through DIGEST_7. The ROM also contains an expected ROM digest. Unlike the rest of the contents of ROM, this isn't scrambled. As such, software can't read it through the standard ROM interface (which would try to unscramble it again, resulting in rubbish data that would cause a failed ECC check). In case software needs access to this value, it can be read at EXP_DIGEST_0 through EXP_DIGEST_7.

Device Interface Functions (DIFs)