Hello,

Is it possible to get the power consumption? The total power consumption can be viewed in the Wolf Portal - so I guess there has to be something to pull it from.

Any ideas on how to do that?

@mr-gosh
Copy link

mr-gosh commented Aug 29, 2024

Would be interesting to add that to the energy-board.
I didn't find a value that correspondends

@b3nn0
Copy link
Owner

b3nn0 commented Aug 29, 2024

Can't really say where this info is coming from. If anything, you'd need to open an Issue at zivillian/ism7mqtt.
Personally, I monitor power consumption by calculating it in a template sensor via Modulationsgrad/100 * peak heat output of the gas heater.
By checking the 3-wege-ventil, you can even distinguish kWh used for heating and warm water.

@zivillian
Copy link

I've also seen this in the app, but haven't looked into it yet, so feel free to open an issue in zivillian/ism7mqtt

@LAdegeest
Copy link

Consumed Power is available via sensor.wolf_cha_0x3_270049_leistungsaufnahme_wp_ehz (ValueId 270049 ). It corresponds very well with what you see in Smartset app. I measure the power also using CT-clams, which results in slightly higher value. Guess it has to do with the control unit itself, which also uses some power.