You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
1 2 3 4 5 6
| | | | | |
$--RPM,a,x,x.x,x.x,A*hh
1) Source; S = Shaft, E = Engine
2) Engine or shaft number
3) Speed, Revolutions per minute
4) Propeller pitch, % of maximum, "-" means astern
5) Status, A means data is valid
6) Checksum
The text was updated successfully, but these errors were encountered:
I'm little confused. When I use emulator and the data comes from nmea183 and it is passing thru SignalK to the TCP connections - all is ok on the QTVLM - RPM works. If I connect my Engine HAt who produce only SignalK sentence to Signal K serwer RPM on QTVLM - no works. What is wrong? I think SignalK serwer not decode from Signal K to nmea183 ... ????
Mayby there is some problem with SignalPaths. When I have path tanks.fuel.A.currentLevel - Open CPN dont recognise them. But When I put tanks.fuel.1.currentLevel all is Ok. I mean engine dashboard not DasboardSK - In this we can choose paths
https://www.tronico.fi/OH6NT/docs/NMEA0183.pdf
RPM Revolutions
The text was updated successfully, but these errors were encountered: