Skip to content

Latest commit

 

History

History
735 lines (501 loc) · 37.1 KB

README.md

File metadata and controls

735 lines (501 loc) · 37.1 KB
title description custom_edit_url
Streaming and replication
Replicate and mirror Netdata's metrics through real-time streaming from child to parent nodes. Then combine, correlate, and export.

Each Netdata node is able to replicate/mirror its database to another Netdata node, by streaming the collected metrics in real-time. This is quite different to data archiving to third party time-series databases. The nodes that send metrics are called child nodes, and the nodes that receive metrics are called parent nodes.

There are also proxy nodes, which collect metrics from a child and sends it to a parent.

When one Netdata node streams metrics another, the receiving instance can use the data for all features of a typical Netdata node, for example:

  • Visualize metrics with a dashboard
  • Run health checks that trigger alarms and send alarm notifications
  • Export metrics to an external time-series database

Supported configurations

Netdata without a database or web API (headless collector)

A local Netdata Agent (child), without any database or alarms, collects metrics and sends them to another Netdata node (parent). The same parent can collect data for any number of child nodes and serves alerts for each child.

The node menu shows a list of all "databases streamed to" the parent. Clicking one of those links allows the user to view the full dashboard of the child node. The URL has the form http://parent-host:parent-port/host/child-host/.

In a headless setup, the child acts as a plain data collector. It spawns all external plugins, but instead of maintaining a local database and accepting dashboard requests, it streams all metrics to the parent.

This setup works great to reduce the memory footprint. Depending on the enabled plugins, memory usage is between 6 MiB and 40 MiB. To reduce the memory usage as much as possible, refer to the performance optimization guide.

Database Replication

The local Netdata Agent (child), with a local database (and possibly alarms), collects metrics and sends them to another Netdata node (parent).

The user can use all the functions at both http://child-ip:child-port/ and http://parent-host:parent-port/host/child-host/.

The child and the parent may have different data retention policies for the same metrics.

Alerts for the child are triggered by both the child and the parent. It is possible to enable different alert configurations on the parent and the child.

In order for custom chart names on the child to work correctly, follow the form type.name. The parent will truncate the type part and substitute the original chart type to store the name in the database.

Netdata proxies

The local Netdata Agent(child), with or without a database, collects metrics and sends them to another Netdata node(proxy), which may or may not maintain a database, which forwards them to another Netdata (parent).

Alerts for the child can be triggered by any of the involved hosts that maintains a database.

You can daisy-chain any number of Netdata, each with or without a database and with or without alerts for the child metrics.

Mix and match with exporting engine

All nodes that maintain a database can also send their data to an external database. This allows quite complex setups.

Example:

  1. Netdata nodes A and B do not maintain a database and stream metrics to Netdata node C(live streaming functionality).
  2. Netdata node C maintains a database for A, B, C and archives all metrics to graphite with 10 second detail (exporting functionality).
  3. Netdata node C also streams data for A, B, C to Netdata D, which also collects data from E, F and G from another DMZ (live streaming functionality).
  4. Netdata node D is just a proxy, without a database, that streams all data to a remote site at Netdata H.
  5. Netdata node H maintains a database for A, B, C, D, E, F, G, H and sends all data to opentsdb with 5 seconds detail (exporting functionality)
  6. Alerts are triggered by H for all hosts.
  7. Users can use all Netdata nodes that maintain a database to view metrics (i.e. at H all hosts can be viewed).

Configuration

The following options affect how Netdata streams:

[global]
    memory mode = none | ram | save | map | dbengine

[global].memory mode = none disables the database at this host. This also disables health monitoring because a node can't have health monitoring without a database.

[web]
    mode = none | static-threaded
    accept a streaming request every seconds = 0

[web].mode = none disables the API (Netdata will not listen to any ports). This also disables the registry (there cannot be a registry without an API).

accept a streaming request every seconds can be used to set a limit on how often a parent node will accept streaming requests from its child nodes. 0 sets no limit, 1 means maximum once every second. If this is set, you may see error log entries "... too busy to accept new streaming request. Will be allowed in X secs".

You can use the exporting engine to configure data archiving to an external database (it archives all databases maintained on this host).

Streaming configuration

The new file stream.conf contains streaming configuration for a sending and a receiving Netdata node.

To configure streaming on your system:

  1. Generate an API key using uuidgen. Note: API keys are just random GUIDs. You can use the same API key on all your Netdata, or use a different API key for any pair of sending-receiving Netdata nodes.

  2. Authorize the communication between a pair of sending-receiving Netdata nodes using the generated API key. Once the communication is authorized, the sending Netdata node can push metrics for any number of hosts.

  3. To edit stream.conf, run /etc/netdata/edit-config stream.conf

The following sections describe how you can configure sending and receiving Netdata nodes.

Options for the sending node

This is the section for the sending Netdata node. On the receiving node, [stream].enabled can be no. If it is yes, the receiving node will also stream the metrics to another node (i.e. it will be a proxy).

[stream]
    enabled = yes | no
    destination = IP:PORT[:SSL] ...
    api key = XXXXXXXXXXX

[API_KEY]
    enabled = yes | no

[MACHINE_GUID]
    enabled = yes | no

This is an overview of how these options can be combined:

target memory
mode
web
mode
stream
enabled
exporting alarms dashboard
headless collector none none yes only for data source = as collected not possible no
headless proxy none not none yes only for data source = as collected not possible no
proxy with db not none not none yes possible possible yes
central netdata not none not none no possible possible yes

For the options to encrypt the data stream between the child and the parent, refer to securing the communication

Options for the receiving node

For a receiving Netdata node, the stream.conf looks like this:

# replace API_KEY with your uuidgen generated GUID
[API_KEY]
    enabled = yes
    default history = 3600
    default memory mode = save
    health enabled by default = auto
    allow from = *

You can add many such sections, one for each API key. The above are used as default values for all hosts pushed with this API key.

You can also add sections like this:

# replace MACHINE_GUID with the child /var/lib/netdata/registry/netdata.public.unique.id
[MACHINE_GUID]
    enabled = yes
    history = 3600
    memory mode = save
    health enabled = yes
    allow from = *

The above is the parent configuration of a single host, at the parent end. MACHINE_GUID is the unique id the Netdata generating the metrics (i.e. the Netdata that originally collects them /var/lib/netdata/registry/netdata.unique.id). So, metrics for Netdata A that pass through any number of other Netdata, will have the same MACHINE_GUID.

You can also use default memory mode = dbengine for an API key or memory mode = dbengine for a single host. The additional page cache size and dbengine multihost disk space configuration options are inherited from the global Netdata configuration.

Allow from

allow from settings are Netdata simple patterns: string matches that use * as wildcard (any number of times) and a ! prefix for a negative match. So: allow from = !10.1.2.3 10.* will allow all IPs in 10.* except 10.1.2.3. The order is important: left to right, the first positive or negative match is used.

Tracing

When a child is trying to push metrics to a parent or proxy, it logs entries like these:

2017-02-25 01:57:44: netdata: ERROR: Failed to connect to '10.11.12.1', port '19999' (errno 111, Connection refused)
2017-02-25 01:57:44: netdata: ERROR: STREAM costa-pc [send to 10.11.12.1:19999]: failed to connect
2017-02-25 01:58:04: netdata: INFO : STREAM costa-pc [send to 10.11.12.1:19999]: initializing communication...
2017-02-25 01:58:04: netdata: INFO : STREAM costa-pc [send to 10.11.12.1:19999]: waiting response from remote netdata...
2017-02-25 01:58:14: netdata: INFO : STREAM costa-pc [send to 10.11.12.1:19999]: established communication - sending metrics...
2017-02-25 01:58:14: netdata: ERROR: STREAM costa-pc [send]: discarding 1900 bytes of metrics already in the buffer.
2017-02-25 01:58:14: netdata: INFO : STREAM costa-pc [send]: ready - sending metrics...

The receiving end (proxy or parent) logs entries like these:

2017-02-25 01:58:04: netdata: INFO : STREAM [receive from [10.11.12.11]:33554]: new client connection.
2017-02-25 01:58:04: netdata: INFO : STREAM costa-pc [10.11.12.11]:33554: receive thread created (task id 7698)
2017-02-25 01:58:14: netdata: INFO : Host 'costa-pc' with guid '12345678-b5a6-11e6-8a50-00508db7e9c9' initialized, os: linux, update every: 1, memory mode: ram, history entries: 3600, streaming: disabled, health: enabled, cache_dir: '/var/cache/netdata/12345678-b5a6-11e6-8a50-00508db7e9c9', varlib_dir: '/var/lib/netdata/12345678-b5a6-11e6-8a50-00508db7e9c9', health_log: '/var/lib/netdata/12345678-b5a6-11e6-8a50-00508db7e9c9/health/health-log.db', alarms default handler: '/usr/libexec/netdata/plugins.d/alarm-notify.sh', alarms default recipient: 'root'
2017-02-25 01:58:14: netdata: INFO : STREAM costa-pc [receive from [10.11.12.11]:33554]: initializing communication...
2017-02-25 01:58:14: netdata: INFO : STREAM costa-pc [receive from [10.11.12.11]:33554]: receiving metrics...

For Netdata v1.9+, streaming can also be monitored via access.log.

Securing streaming communications

Netdata does not activate TLS encryption by default. To encrypt streaming connections:

  1. On the parent node (receiving node), enable TLS support.
  2. On the child node (sending node), enable TLS support.
  3. On the child's stream.conf, configure the destination as follows:
[stream]
    destination = host:port:SSL

The word SSL appended to the end of the destination tells the child that connections must be encrypted.

While Netdata uses Transport Layer Security (TLS) 1.2 to encrypt communications rather than the obsolete SSL protocol, it's still common practice to refer to encrypted web connections as SSL. Many vendors, like Nginx and even Netdata itself, use SSL in configuration files, whereas documentation will always refer to encrypted communications as TLS or TLS/SSL.

Certificate verification

When TLS/SSL is enabled on the child, the default behavior will be to not connect with the parent unless the server's certificate can be verified via the default chain. In case you want to avoid this check, add the following to the child's stream.conf file:

[stream]
    ssl skip certificate verification = yes

Trusted certificate

If you've enabled certificate verification, you might see errors from the OpenSSL library when there's a problem with checking the certificate chain (X509_V_ERR_UNABLE_TO_GET_ISSUER_CERT_LOCALLY). More importantly, OpenSSL will reject self-signed certificates.

Given these known issues, you have two options. If you trust your certificate, you can set the options CApath and CAfile to inform Netdata where your certificates, and the certificate trusted file, are stored.

For more details about these options, you can read about verify locations.

Before you changed your streaming configuration, you need to copy your trusted certificate to your child system and add the certificate to OpenSSL's list.

On most Linux distributions, the update-ca-certificates command searches inside the /usr/share/ca-certificates directory for certificates. You should double-check by reading the update-ca-certificate manual (man update-ca-certificate), and then change the directory in the below commands if needed.

If you have sudo configured on your child system, you can use that to run the following commands. If not, you'll have to log in as root to complete them.

# mkdir /usr/share/ca-certificates/netdata
# cp parent_cert.pem /usr/share/ca-certificates/netdata/parent_cert.crt
# chown -R netdata.netdata /usr/share/ca-certificates/netdata/

First, you create a new directory to store your certificates for Netdata. Next, you need to change the extension on your certificate from .pem to .crt so it's compatible with update-ca-certificate. Finally, you need to change permissions so the user that runs Netdata can access the directory where you copied in your certificate.

Next, edit the file /etc/ca-certificates.conf and add the following line:

netdata/parent_cert.crt

Now you update the list of certificates running the following, again either as sudo or root:

# update-ca-certificates

Some Linux distributions have different methods of updating the certificate list. For more details, please read this guide on adding trusted root certificates.

Once you update your certificate list, you can set the stream parameters for Netdata to trust the parent certificate. Open stream.conf for editing and change the following lines:

[stream]
    CApath = /etc/ssl/certs/
    CAfile = /etc/ssl/certs/parent_cert.pem

With this configuration, the CApath option tells Netdata to search for trusted certificates inside /etc/ssl/certs. The CAfile option specifies the Netdata parent certificate is located at /etc/ssl/certs/parent_cert.pem. With this configuration, you can skip using the system's entire list of certificates and use Netdata's parent certificate instead.

Expected behaviors

With the introduction of TLS/SSL, the parent-child communication behaves as shown in the table below, depending on the following configurations:

  • Parent TLS (Yes/No): Whether the [web] section in netdata.conf has ssl key and ssl certificate.
  • Parent port TLS (-/force/optional): Depends on whether the [web] section bind to contains a ^SSL=force or ^SSL=optional directive on the port(s) used for streaming.
  • Child TLS (Yes/No): Whether the destination in the child's stream.conf has :SSL at the end.
  • Child TLS Verification (yes/no): Value of the child's stream.conf ssl skip certificate verification parameter (default is no).
Parent TLS enabled Parent port SSL Child TLS Child SSL Ver. Behavior
No - No no Legacy behavior. The parent-child stream is unencrypted.
Yes force No no The parent rejects the child connection.
Yes -/optional No no The parent-child stream is unencrypted (expected situation for legacy child nodes and newer parent nodes)
Yes -/force/optional Yes no The parent-child stream is encrypted, provided that the parent has a valid TLS/SSL certificate. Otherwise, the child refuses to connect.
Yes -/force/optional Yes yes The parent-child stream is encrypted.

Streaming compression

Supported version Netdata Agent release

Supported version Netdata Agent release

OS dependencies

  • Streaming compression is based on lz4 v1.9.0+. The lz4 v1.9.0+ library must be installed in your OS in order to enable streaming compression. Any lower version will disable Netdata streaming compression for compatibility purposes between the older versions of Netdata agents.

To check if your Netdata Agent supports stream compression run the following GET request in your browser or terminal:

curl -X GET http://localhost:19999/api/v1/info | grep 'Stream Compression'

Output

"buildinfo": "dbengine|Native HTTPS|Netdata Cloud|ACLK Next Generation|New Cloud Protocol Support|ACLK Legacy|TLS Host Verification|Machine Learning|Stream Compression|protobuf|JSON-C|libcrypto|libm|LWS v3.2.2|mosquitto|zlib|apps|cgroup Network Tracking|EBPF|perf|slabinfo",

Note: If your OS doesn't support Netdata compression the buildinfo will not contain the Stream Compression statement.

To check if your Netdata Agent has stream compression enabled, run the following GET request in your browser or terminal:

 curl -X GET http://localhost:19999/api/v1/info | grep 'stream-compression'

Output

"stream-compression": "enabled"

Note: The stream-compression status can be "enabled" | "disabled" | "N/A".

A compressed data packet is determined and decompressed on the fly.

Limitations

This limitation will be withdrawn asap and is work-in-progress.

The current implementation of streaming data compression can support only a few number of dimensions in a chart with names that cannot exceed the size of 16384 bytes. In case your instance hit this limitation, the agent will deactivate compression during runtime to avoid stream corruption. This limitation can be seen in the error.log file with the sequence of the following messages:

netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: connecting...
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: initializing communication...
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: waiting response from remote netdata...
netdata INFO  : STREAM_SENDER[child01] : STREAM_COMPRESSION: Compressor Reset
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: established communication with a parent using protocol version 5 - ready to send metrics...
...
netdata ERROR : PLUGINSD[go.d] : STREAM_COMPRESSION: Compression Failed - Message size 27847 above compression buffer limit: 16384 (errno 9, Bad file descriptor)
netdata ERROR : PLUGINSD[go.d] : STREAM_COMPRESSION: Deactivating compression to avoid stream corruption
netdata ERROR : PLUGINSD[go.d] : STREAM_COMPRESSION child01 [send to my.parent.IP]: Restarting connection without compression
...
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: connecting...
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: initializing communication...
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: waiting response from remote netdata...
netdata INFO  : STREAM_SENDER[child01] : Stream is uncompressed! One of the agents (my.parent.IP <-> child01) does not support compression OR compression is disabled.
netdata INFO  : STREAM_SENDER[child01] : STREAM child01 [send to my.parent.IP]: established communication with a parent using protocol version 4 - ready to send metrics...
netdata INFO  : WEB_SERVER[static4] : STREAM child01 [send]: sending metrics...

How to enable stream compression

Netdata Agents are shipped with data compression enabled by default. You can also configure which streams will use compression.

With enabled stream compression, a Netdata Agent can negotiate streaming compression with other Netdata Agents. During the negotiation of streaming compression both Netdata Agents should support and enable compression in order to communicate over a compressed stream. The negotiation will result into an uncompressed stream, if one of the Netdata Agents doesn't support or has compression disabled.

To enable stream compression:

  1. Edit stream.conf by using the edit-config script: /etc/netdata/edit-config stream.conf.

  2. In the [stream] section, set enable compression to yes.

# This is the default stream compression flag for an agent.

[stream]
    enable compression = yes | no
Parent Stream compression Child
Supported & Enabled compressed Supported & Enabled
(Supported & Disabled)/Not supported uncompressed Supported & Enabled
Supported & Enabled uncompressed (Supported & Disabled)/Not supported
(Supported & Disabled)/Not supported uncompressed (Supported & Disabled)/Not supported

In case of parents with multiple children you can select which streams will be compressed by using the same configuration under the [API_KEY], [MACHINE_GUID] section.

This configuration uses AND logic with the default stream compression configuration under the [stream] section. This means the stream compression from child to parent will be enabled only if the outcome of the AND logic operation is true (default compression enabled && api key compression enabled). So both should be enabled to get stream compression otherwise stream compression is disabled.

[API_KEY]
    enable compression = yes | no

Same thing applies with the [MACHINE_GUID] configuration.

[MACHINE_GUID]
    enable compression = yes | no

Viewing remote host dashboards, using mirrored databases

On any receiving Netdata, that maintains remote databases and has its web server enabled, The node menu will include a list of the mirrored databases.

image

Selecting any of these, the server will offer a dashboard using the mirrored metrics.

Monitoring ephemeral nodes

Auto-scaling is probably the most trendy service deployment strategy these days.

Auto-scaling detects the need for additional resources and boots VMs on demand, based on a template. Soon after they start running the applications, a load balancer starts distributing traffic to them, allowing the service to grow horizontally to the scale needed to handle the load. When demands falls, auto-scaling starts shutting down VMs that are no longer needed.

Monitoring ephemeral nodes with Netdata

What a fantastic feature for controlling infrastructure costs! Pay only for what you need for the time you need it!

In auto-scaling, all servers are ephemeral, they live for just a few hours. Every VM is a brand new instance of the application, that was automatically created based on a template.

So, how can we monitor them? How can we be sure that everything is working as expected on all of them?

The Netdata way

We recently made a significant improvement at the core of Netdata to support monitoring such setups.

Following the Netdata way of monitoring, we wanted:

  1. real-time performance monitoring, collecting thousands of metrics per server per second, visualized in interactive, automatically created dashboards.
  2. real-time alarms, for all nodes.
  3. zero configuration, all ephemeral servers should have exactly the same configuration, and nothing should be configured at any system for each of the ephemeral nodes. We shouldn't care if 10 or 100 servers are spawned to handle the load.
  4. self-cleanup, so that nothing needs to be done for cleaning up the monitoring infrastructure from the hundreds of nodes that may have been monitored through time.

How it works

All monitoring solutions, including Netdata, work like this:

  1. Collect metrics from the system and the running applications
  2. Store metrics in a time-series database
  3. Examine metrics periodically, for triggering alarms and sending alarm notifications
  4. Visualize metrics so that users can see what exactly is happening

Netdata used to be self-contained, so that all these functions were handled entirely by each server. The changes we made, allow each Netdata to be configured independently for each function. So, each Netdata can now act as:

  • A self-contained system, much like it used to be.
  • A data collector that collects metrics from a host and pushes them to another Netdata (with or without a local database and alarms).
  • A proxy, which receives metrics from other hosts and pushes them immediately to other Netdata servers. Netdata proxies can also be store and forward proxies meaning that they are able to maintain a local database for all metrics passing through them (with or without alarms).
  • A time-series database node, where data are kept, alarms are run and queries are served to visualise the metrics.

Configuring an auto-scaling setup

A diagram of an auto-scaling setup with Netdata

You need a Netdata parent. This node should not be ephemeral. It will be the node where all ephemeral child nodes will send their metrics.

The parent will need to authorize child nodes to receive their metrics. This is done with an API key.

API keys

API keys are just random GUIDs. Use the Linux command uuidgen to generate one. You can use the same API key for all your child nodes, or you can configure one API for each of them. This is entirely your decision.

We suggest to use the same API key for each ephemeral node template you have, so that all replicas of the same ephemeral node will have exactly the same configuration.

I will use this API_KEY: 11111111-2222-3333-4444-555555555555. Replace it with your own.

Configuring the parent

To configure the parent node:

  1. On the parent node, edit stream.conf by using the edit-config script: /etc/netdata/edit-config stream.conf

  2. Set the following parameters:

[11111111-2222-3333-4444-555555555555]
	# enable/disable this API key
    enabled = yes

    # one hour of data for each of the child nodes
    default history = 3600

    # do not save child metrics on disk
    default memory = ram

    # alarms checks, only while the child is connected
    health enabled by default = auto

stream.conf on the parent, to enable receiving metrics from its child nodes using the API key.

If you used many API keys, you can add one such section for each API key.

When done, restart Netdata on the parent node. It is now ready to receive metrics.

Note that health enabled by default = auto will still trigger last_collected alarms, if a connected child does not exit gracefully. If the netdata process running on the child is stopped, it will close the connection to the parent, ensuring that no last_collected alarms are triggered. For example, a proper container restart would first terminate the netdata process, but a system power issue would leave the connection open on the parent side. In the second case, you will still receive alarms.

Configuring the child nodes

To configure the child node:

  1. On the child node, edit stream.conf by using the edit-config script: /etc/netdata/edit-config stream.conf

  2. Set the following parameters:

[stream]
    # stream metrics to another Netdata
    enabled = yes

    # the IP and PORT of the parent
    destination = 10.11.12.13:19999

	# the API key to use
    api key = 11111111-2222-3333-4444-555555555555

stream.conf on child nodes, to enable pushing metrics to their parent at 10.11.12.13:19999.

Using just the above configuration, the child nodes will be pushing their metrics to the parent Netdata, but they will still maintain a local database of the metrics and run health checks. To disable them, edit /etc/netdata/netdata.conf and set:

[global]
    # disable the local database
	memory mode = none

[health]
    # disable health checks
    enabled = no

netdata.conf configuration on child nodes, to disable the local database and health checks.

Keep in mind that setting memory mode = none will also force [health].enabled = no (health checks require access to a local database). But you can keep the database and disable health checks if you need to. You are however sending all the metrics to the parent node, which can handle the health checking ([health].enabled = yes)

Netdata unique ID

The file /var/lib/netdata/registry/netdata.public.unique.id contains a random GUID that uniquely identifies each Netdata Agent. This file is automatically generated, by Netdata, the first time it is started and remains unaltered forever.

If you are building an image to be used for automated provisioning of autoscaled VMs, it important to delete that file from the image, so that each instance of your image will generate its own.

Troubleshooting metrics streaming

Both parent and child nodes log information at /var/log/netdata/error.log.

To obtain the error logs, run the following on both the parent and child nodes:

tail -f /var/log/netdata/error.log | grep STREAM

If the child manages to connect to the parent you will see something like (on the parent):

2017-03-09 09:38:52: netdata: INFO : STREAM [receive from [10.11.12.86]:38564]: new client connection.
2017-03-09 09:38:52: netdata: INFO : STREAM xxx [10.11.12.86]:38564: receive thread created (task id 27721)
2017-03-09 09:38:52: netdata: INFO : STREAM xxx [receive from [10.11.12.86]:38564]: client willing to stream metrics for host 'xxx' with machine_guid '1234567-1976-11e6-ae19-7cdd9077342a': update every = 1, history = 3600, memory mode = ram, health auto
2017-03-09 09:38:52: netdata: INFO : STREAM xxx [receive from [10.11.12.86]:38564]: initializing communication...
2017-03-09 09:38:52: netdata: INFO : STREAM xxx [receive from [10.11.12.86]:38564]: receiving metrics...

and something like this on the child:

2017-03-09 09:38:28: netdata: INFO : STREAM xxx [send to box:19999]: connecting...
2017-03-09 09:38:28: netdata: INFO : STREAM xxx [send to box:19999]: initializing communication...
2017-03-09 09:38:28: netdata: INFO : STREAM xxx [send to box:19999]: waiting response from remote netdata...
2017-03-09 09:38:28: netdata: INFO : STREAM xxx [send to box:19999]: established communication - sending metrics...

Archiving to a time-series database

The parent Netdata node can also archive metrics, for all its child nodes, to a time-series database. At the time of this writing, Netdata supports:

  • graphite
  • opentsdb
  • prometheus
  • json document DBs
  • all the compatibles to the above (e.g. kairosdb, influxdb, etc)

Check the Netdata exporting documentation for configuring this.

This is how such a solution will work:

Diagram showing an example configuration for archiving to a time-series database

An advanced setup

Netdata also supports proxies with and without a local database, and data retention can be different between all nodes.

This means a setup like the following is also possible:

Proxies

A proxy is a Netdata node that is receiving metrics from a Netdata node, and streams them to another Netdata node.

Netdata proxies may or may not maintain a database for the metrics passing through them. When they maintain a database, they can also run health checks (alarms and notifications) for the remote host that is streaming the metrics.

To configure a proxy, configure it as a receiving and a sending Netdata at the same time, using stream.conf.

The sending side of a Netdata proxy, connects and disconnects to the final destination of the metrics, following the same pattern of the receiving side.

For a practical example see Monitoring ephemeral nodes.

Troubleshooting streaming connections

This section describes the most common issues you might encounter when connecting parent and child nodes.

Slow connections between parent and child

When you have a slow connection between parent and child, Netdata raises a few different errors. Most of the errors will appear in the child's error.log.

netdata ERROR : STREAM_SENDER[CHILD HOSTNAME] : STREAM CHILD HOSTNAME [send to PARENT IP:PARENT PORT]: too many data pending - buffer is X bytes long,
Y unsent - we have sent Z bytes in total, W on this connection. Closing connection to flush the data.

On the parent side, you may see various error messages, most commonly the following:

netdata ERROR : STREAM_PARENT[CHILD HOSTNAME,[CHILD IP]:CHILD PORT] : read failed: end of file

Another common problem in slow connections is the CHILD sending a partial message to the parent. In this case, the parent will write the following in its error.log:

ERROR : STREAM_RECEIVER[CHILD HOSTNAME,[CHILD IP]:CHILD PORT] : sent command 'B' which is not known by netdata, for host 'HOSTNAME'. Disabling it.

In this example, B was part of a BEGIN message that was cut due to connection problems.

Slow connections can also cause problems when the parent misses a message and then receives a command related to the missed message. For example, a parent might miss a message containing the child's charts, and then doesn't know what to do with the SET message that follows. When that happens, the parent will show a message like this:

ERROR : STREAM_RECEIVER[CHILD HOSTNAME,[CHILD IP]:CHILD PORT] : requested a SET on chart 'CHART NAME' of host 'HOSTNAME', without a dimension. Disabling it.

Child cannot connect to parent

When the child can't connect to a parent for any reason (misconfiguration, networking, firewalls, parent down), you will see the following in the child's error.log.

ERROR : STREAM_SENDER[HOSTNAME] : Failed to connect to 'PARENT IP', port 'PARENT PORT' (errno 113, No route to host)

'Is this a Netdata node?'

This question can appear when Netdata starts the stream and receives an unexpected response. This error can appear when the parent is using SSL and the child tries to connect using plain text. You will also see this message when Netdata connects to another server that isn't a Netdata node. The complete error message will look like this:

ERROR : STREAM_SENDER[CHILD HOSTNAME] : STREAM child HOSTNAME [send to PARENT HOSTNAME:PARENT PORT]: server is not replying properly (is it a netdata?).

Stream charts wrong

Chart data needs to be consistent between child and parent nodes. If there are differences between chart data on a parent and a child, such as gaps in metrics collection, it most often means your child's memory mode does not match the parent's. To learn more about the different ways Netdata can store metrics, and thus keep chart data consistent, read our memory mode documentation.

Forbidding access

You may see errors about "forbidding access" for a number of reasons. It could be because of a slow connection between the parent and child nodes, but it could also be due to other failures. Look in your parent's error.log for errors that look like this:

STREAM [receive from [child HOSTNAME]:child IP]: `MESSAGE`. Forbidding access."

MESSAGE will have one of the following patterns:

  • request without KEY : The message received is incomplete and the KEY value can be API, hostname, machine GUID.
  • API key 'VALUE' is not valid GUID: The UUID received from child does not have the format defined in [RFC 4122] (https://tools.ietf.org/html/rfc4122)
  • machine GUID 'VALUE' is not GUID.: This error with machine GUID is like the previous one.
  • API key 'VALUE' is not allowed: This stream has a wrong API key.
  • API key 'VALUE' is not permitted from this IP: The IP is not allowed to use STREAM with this parent.
  • machine GUID 'VALUE' is not allowed.: The GUID that is trying to send stream is not allowed.
  • Machine GUID 'VALUE' is not permitted from this IP. : The IP does not match the pattern or IP allowed to connect to use stream.

Netdata could not create a stream

The connection between parent and child is a stream. When the parent can't convert the initial connection into a stream, it will write the following message inside error.log:

file descriptor given is not a valid stream

After logging this error, Netdata will close the stream.