You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Acid and Chlorine tank levels are now estimated and reported in % fill (estimation based on the running-time of each pump)
/!\ API change. MQTT published payloads now also include stored Orp, pH and Water temp setpoints as well as tank-level estimates. Two separate publishes are used in order to reduce the payload size of each publish
A daily 2 minutes cycling of the water heating circulator has been added in order to maintain it in good condition when not being used for long period of times (eg. in winter)
Pump class now support setups in which PoolMaster does not manage the filtration pump (eg. in cases where an already-installed automate handles it). See Pump class for more info