- Extended conversion factor range to 25-12800 cpm/µSv/h.
- When using sensitive detectors with a conversion factor of 600 cpm/µSv/h or higher, Rad Pro caps the pulse indication at 600 cpm/µSv/h to provide approximately one pulse per second at background levels of radiation. This does not impact the actual measurement.
- Minor UI and performance refinements.
- Improved the instantaneous rate averaging algorithm.
- Simplified the instantaneous rate averaging response curves, resulting in improved precision when using J613/J614 tubes.
- Disabled instantaneous rate alarms in situations where the confidence interval is high, such as immediately after device startup.
- Minor UI improvements.
- Added data log reset.
- Changed the default conversion factor for J613/J614 tubes to 60.0 cpm/µSv/h.
- Resolved issues with custom HV profiles.
- Resolved issues with the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests.
- Resolved issues with new history data log download.
- Minor refinements.
- First 2.0 release.
- Updated the UI design system to OpenBridge 5.0, improving legibility under sunlight.
- Changed the default conversion factor for J613/J614 tubes to 30.0 cpm/µSv/h.
- Removed the FNIRSI GC-01 display panel settings.
- Increased the granularity and range of the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests to CPU clock resolution and 100 Hz-100 kHz and 0%-100%, respectively (not stored on power-off).
- Added Bosean FS-5000 support.
- Added display panel menu for selecting the display panel (on supported devices).
- Added secondary dose view in average measurement mode.
- Extended conversion factor range to 25-1600 cpm/µSv/h.
- Added 1 second data log interval options and removed 30 seconds and 30 minutes data log interval options.
- Added "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection commands.
- Added 12-hour time format.
- Devices with data mode allow using the device while data mode is active; data mode state is also preserved after powering off.
- Improved battery level indicator of the Bosean FS-600/FS-1000.
- Improved battery level readout of the FS2011(STM32F051), Bosean FS-600/FS-1000.
- Improved keyboard control scheme of the Bosean FS-1000.
- Changed USB data connection end of line to "\r\n".
- Minor refinements.
- Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
- Added secondary CPM and count displays in measurement views.
- Improved haptic pulse strengths.
- Improved FNIRSI GC-01 quiet pulse clicks.
- Improved selected menu item contrast.
- Improved data logging time precision.
- Fixed History (24 h) bug.
- UI update with big digits in measurement view.
- Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
- History alert zones (1 µSv, 10 µSv).
- Average timer expiration after reaching a configurable confidence interval.
- Background compensation.
- Display flashes on the FNIRSI GC-01 (after display sleep).
- Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
- Pulse thresholding (disables pulse indication if instantaneous rate is below a certain value).
- Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
- Added 30 second and 10 second data log interval options.
- Added 10 second display sleep option.
- Added
radpro-flashtool
. - Removed measurement hold.
- Fixed flash programming.
- Fixed FNIRSI GC-01 battery indicator.
- Fixed conversion factor menu logic.
- Added FNIRSI GC-01 support.
- Added data logging.
- Added custom conversion factors.
- Added support for the J305 Geiger tube.
- Minor bug fixes.
- Added support for devices with a GD32 microcontroller.
- Added data submission to the https://gmcmap.com/ radiation monitoring website.
- Minor bugfixes.
- Implemented storage of radiation dose in non-volatile memory.
- Added the capability to store device statistics every hour.
- Added client for the https://radmon.org radiation monitoring website.
- Improved the font_tiny5 5-pixel font.
- Enhanced battery level calculation using battery discharge curves and HV pulse syncing for shot noise removal.
- Improved flash settings and state storage.
- Fixed a start-up sequence bug.
- Fixed a backlight bug when turning off the device.
- Corrected the SBM-20 conversion ratio.
- Minor bug fix
- Added Geiger-Müller tube type settings.
- Added backlight pulse flash setting.
- Added true random number generator.
- Added support for the SBM-20 and SI-3BG Geiger-Müller tube.
- Ported the project to the platform.io environment.
- Improved battery level sampling.
- Fixed rounding errors.
- Improved usage instructions.
- Added support for M4011 Geiger-Müller tube.
- Fixed battery indicator.
- Improved pulse click volume.
- Fixed battery indicator.
- Fixed several bugs in Nuclear chess.
- First release