Skip to content

Latest commit

 

History

History
 
 

thermo29

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 
 
 
 
 
 
 

\mainpage Main Page


Thermo 29 click

Thermo 29 Click is a compact add-on board for accurate temperature measurements. This board features the TMP126, a high-accuracy SPI-configurable digital temperature sensor from Texas Instruments. The TMP126 consists of an internal thermal BJT factory-calibrated sensor, 14-bit ADC, and a digital signal processor, offering a high accuracy of ±0.25°C and a temperature resolution of 0.03125°C per LSB. It also has a programmable alarm function that outputs an interrupt signal to the MCU when a specific temperature event occurs.

click Product page


Click library

  • Author : Stefan Filipovic
  • Date : Jan 2023.
  • Type : SPI type

Software Support

We provide a library for the Thermo 29 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Thermo 29 Click driver.

Standard key functions :

  • thermo29_cfg_setup Config Object Initialization function.
void thermo29_cfg_setup ( thermo29_cfg_t *cfg );
  • thermo29_init Initialization function.
err_t thermo29_init ( thermo29_t *ctx, thermo29_cfg_t *cfg );
  • thermo29_default_cfg Click Default Configuration function.
err_t thermo29_default_cfg ( thermo29_t *ctx );

Example key functions :

  • thermo29_read_unique_id This function reads the device unique ID words (6 bytes in total).
err_t thermo29_read_unique_id ( thermo29_t *ctx, uint16_t *unique_id );
  • thermo29_get_alert_pin This function returns the alert pin logic state.
uint8_t thermo29_get_alert_pin ( thermo29_t *ctx );
  • thermo29_read_temperature This function reads the temperature measurement in degrees Celsius.
err_t thermo29_read_temperature ( thermo29_t *ctx, float *temperature );

Example Description

This example demonstrates the use of Thermo 29 click board by reading and displaying the temperature measurements.

The demo application is composed of two sections :

Application Init

Initializes the driver and logger, and performs the click default configuration which enables continuous conversion and sets the conversion rate to 1 Hz with a data ready flag enabled on the alert pin. After that, reads and displays the device 48-bit unique ID.

void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    thermo29_cfg_t thermo29_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    thermo29_cfg_setup( &thermo29_cfg );
    THERMO29_MAP_MIKROBUS( thermo29_cfg, MIKROBUS_1 );
    if ( SPI_MASTER_ERROR == thermo29_init( &thermo29, &thermo29_cfg ) )
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    
    if ( THERMO29_ERROR == thermo29_default_cfg ( &thermo29 ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }
    
    uint16_t unique_id[ 3 ];
    if ( THERMO29_OK == thermo29_read_unique_id ( &thermo29, unique_id ) )
    {
        log_printf ( &logger, " Device Unique ID: 0x%.2X%.2X%.2X\r\n", 
                     unique_id[ 0 ], unique_id[ 1 ], unique_id[ 2 ] );
    }
    
    log_info( &logger, " Application Task " );
}

Application Task

Waits for the data ready alert flag, then reads the temperature measurement in Celsius and displays the results on the USB UART approximately once per second.

void application_task ( void )
{
    float temperature;
    // Wait for the data ready alert flag
    while ( thermo29_get_alert_pin ( &thermo29 ) );
    
    if ( ( THERMO29_OK == thermo29_clear_alert_status ( &thermo29 ) ) && 
         ( THERMO29_OK == thermo29_read_temperature ( &thermo29, &temperature ) ) )
    {
        log_printf ( &logger, " Temperature: %.2f degC\r\n\n", temperature );
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Thermo29

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.