Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Option to ignore degraded storage LUNs #165

Open
GalipoliX opened this issue Jan 2, 2020 · 2 comments
Open

Option to ignore degraded storage LUNs #165

GalipoliX opened this issue Jan 2, 2020 · 2 comments

Comments

@GalipoliX
Copy link
Contributor

It would be great to have an option to ignore LUNs that are in state ok-degraded in select Storage subselect lun.

Background:
On systems with iscsi disk that only have one path, vmware seems to report them as degraded.

image

But in this case this is totaly fine.

Thanks!

@majales
Copy link

majales commented May 19, 2020

Hi, I have experienced the same problem. It is only reported as ok-degraded in systems with multiple storage paths. Systems with single path are OK. So please, would you implement this option to ignore ok-degraded luns? Thank you.

@BaldMansMojo
Copy link
Owner

Sorry for the late answer. Give me please the check command. I can't reproduce it. Normally this only happens when multipathing is configured but there is only on path available.